Rankine cycle, reheat and regeneration

Rankine cycle with reheat and regeneration: definitions, assumptions, T–s picture, isentropic efficiencies, open/closed feedwater heaters, extraction mass balances, performance metrics (η, SSC, BWR), typical trade-offs, and solved numericals.

Drafted with Aria, reviewed by the AiCanCode.org team · Updated . How we write and check our notes. Spotted an error? Use Give Feedback at the bottom of the page.

Why it matters

Steam power plants in India (thermal stations and many captive units) run on the Rankine cycle; reheat and regeneration are the two standard upgrades that improve durability and efficiency. Understanding how they change work output, moisture at turbine exit, and boiler/condenser duties is central to design, O&M, GATE ME, PSUs, and core interviews.

Key ideas

  • Rankine cycle (basic): A vapor power cycle with four ideal processes: (1) pumping saturated liquid from condenser pressure to boiler pressure, (2) heat addition in the boiler (often to superheat), (3) expansion through the turbine to condenser pressure, and (4) heat rejection in the condenser to saturated liquid. Assumptions for the ideal cycle: steady flow, negligible changes in kinetic and potential energies, no pressure drops in heat exchangers and pipes, pump and turbine are isentropic, saturated liquid leaves the condenser, and saturated liquid (or specified feedwater state) enters the boiler.

  • Sign convention used here: Heat added to the working fluid is positive, turbine work delivered is positive, and pump work input is treated as a positive quantity when computing back work ratio but is subtracted to get net work of the cycle.

  • T–s diagram: The area under the expansion line represents turbine work, and the area under the heat addition path represents heat input. The mean temperature of heat addition is lower than the boiler metal temperature; this is why a Rankine cycle’s efficiency is lower than a Carnot cycle operating between the same extreme temperatures.

  • Thermal efficiency (η_th): Ratio of net work to heat added in the cycle. For ideal Rankine, η_th increases when: boiler pressure and/or superheat temperature increase (within material limits), condenser pressure decreases, regeneration is used (raising feedwater temperature), and moderate reheat is used (raising work output and reducing moisture).

  • Back work ratio (BWR): Fraction of turbine work consumed by the pump(s). In steam plants BWR is small (typically below a few percent) because liquid is nearly incompressible; in gas turbines BWR is large.

  • Specific steam consumption (SSC): Steam flow per unit power output; used for plant sizing and performance comparison. It inversely tracks the net specific work.

  • Why real devices differ from ideal:

    • Turbine isentropic efficiency (η_t) < 1 due to friction, shock, wetness losses, tip leakage.
    • Pump isentropic efficiency (η_p) < 1 due to hydraulic losses and disk friction.
    • Pressure drops in boiler and condenser, and moisture formation in LP turbine cause additional irreversibilities.
    • Metallurgical limits cap superheat and reheat temperatures; condenser pressure is limited by cooling water temperature and vacuum limitations.
  • Reheat Rankine cycle:

    • Purpose: (i) reduce moisture content at the LP turbine exit to limit blade erosion and efficiency loss, (ii) increase total turbine work. Method: expand in stages; after partial expansion to an intermediate reheat pressure, route steam back to the boiler (reheater) at essentially constant pressure, reheat near the main steam temperature, then expand through the LP turbine to condenser pressure.
    • Assumptions (ideal reheat): adiabatic, steady turbines; reheater at constant pressure; no pressure drops in ducting; pumps/turbines isentropic unless stated.
    • Effects: increases specific work, often improves thermal efficiency modestly, and raises exit dryness fraction. There is an optimum reheat pressure range (rule-of-thumb near the geometric mean of boiler and condenser pressures for idealized property models), but practical selection depends on blade path, moisture constraints, and reheater/boiler design.
  • Regeneration (feedwater heating):

    • Purpose: increase the average temperature of heat addition by preheating feedwater using steam bled (extracted) from intermediate turbine stages. This reduces the external heat input required for the same turbine work and improves η_th.
    • Two common types:
      • Open feedwater heater (OFWH, direct-contact): extracted steam mixes directly with feedwater at the heater pressure; outlet is saturated liquid at that pressure. Requires that the pumps arrange pressures so streams can mix isobarically.
      • Closed feedwater heater (CFWH, surface type): extracted steam condenses on the shell side transferring heat to the feedwater through a surface; the drains are either cascaded to a lower-pressure heater or throttled/mixed depending on the scheme. Pressure levels are independent on the two sides. No direct mixing; deaeration is separate.
    • Assumptions (ideal regeneration): extract steam at the heater pressure with negligible pressure drops; OFWH outlet is saturated liquid at the heater pressure; heaters and connecting lines are adiabatic to surroundings; drains from CFWHs leave as saturated liquid at the heater pressure.
    • Mass and energy balances (one OFWH): if y is the mass fraction extracted to the OFWH, with feedwater enthalpy h_fw,in from pump and extracted steam enthalpy h_ex, the OFWH outlet enthalpy h_fw,out satisfies y·h_ex + (1−y)·h_fw,in = h_fw,out. Solve for y. This y reduces the mass flow continuing to downstream turbine stages and the reheater (if present): that flow equals (1−y) per unit main flow.
    • Effects: increases η_th but often reduces net specific work (less mass flow through LP stages), lowers condenser load (since some steam is condensed in heaters instead), and improves cycle heat rate. Multiple heaters give diminishing returns; as the number of heaters increases and their pressures are properly distributed, the cycle approaches a Carnot-like heat addition path in the T–s plane.
  • Quality (dryness fraction) at turbine exit: In saturated region, s = s_f + x·s_fg and h = h_f + x·h_fg. Designers typically limit moisture at LP turbine exit to ~10–12% (x ≥ ~0.88–0.90) for reliability; reheat is the standard remedy to raise x.

  • Isentropic efficiencies (definitions used in analysis):

    • Turbine: η_t = actual turbine work / isentropic turbine work = (h_in − h_out,actual) / (h_in − h_out,isentropic) for the same inlet state and exit pressure.
    • Pump: η_p = isentropic pump work / actual pump work = (h_out,isentropic − h_in) / (h_out,actual − h_in) for the same inlet state and exit pressure.
  • Limiting and standard cases:

    • With no reheat and no regeneration, the cycle is the simple Rankine cycle.
    • With reheat only (y = 0), turbine exit moisture decreases and work increases; η_th changes modestly depending on conditions.
    • With regeneration only (no reheat), η_th increases due to higher feedwater temperature; turbine exit moisture may still be high if there is significant expansion without reheat.
    • With many ideal heaters (and appropriately chosen pressures), the ideal regenerative Rankine can approach Carnot efficiency for the same extremes.
  • What to optimize in practice: number and pressure levels of heaters, reheat pressure(s), superheat and reheat temperatures, condenser pressure, and blade-path moisture constraints; balanced against capital cost and boiler-turbine limitations.

Formulas

  • η_th = w_net / q_in Thermal efficiency; dimensionless. Applies to any cycle.

  • w_t,is = h_in − h_out,is and w_t,act = h_in − h_out,act, with η_t = w_t,act / w_t,is Turbine specific works (kJ/kg) and turbine isentropic efficiency (dimensionless). Use for each expansion stage at fixed exit pressure.

  • w_p,is = v · (p_out − p_in) (for compressed liquid) and η_p = w_p,is / w_p,act Pump specific work (kJ/kg); v in m³/kg, p in Pa (1 kPa = 1000 Pa). Use when liquid is nearly incompressible.

  • q_in = (h_boiler,out − h_fw,at_boiler_in) + Σ(reheat additions) Total heat added per kg of main flow (kJ/kg). For reheat, multiply the reheat enthalpy rise by the mass fraction that is reheated.

  • w_net = (Σ turbine works over the actual mass in each stage) − (Σ pump works) Net specific work (kJ/kg). Remember only (1 − y) continues past an extraction point.

  • BWR = w_p,total / w_t,total Back work ratio; dimensionless. Small for steam cycles.

  • SSC = 3600 / w_net Specific steam consumption (kg/kWh), with w_net in kJ/kg and power basis 1 kW = 1 kJ/s. Applies per kg/s of main steam flow.

  • Heat rate = 3600 / η_th Heat rate (kJ/kWh) for the unit, from η_th = W_out / Q_in.

  • For quality at turbine exit (in two-phase region): x = (s − s_f) / s_fg or x = (h − h_f) / h_fg Dryness fraction at given pressure; s in kJ/kg·K, h in kJ/kg. Use saturation properties at the condenser (or stage) pressure.

  • Open feedwater heater (one extraction): y = (h_fw,out − h_fw,in) / (h_ex − h_fw,in) y is the extracted mass fraction (kg extracted per kg main). h_ex is enthalpy of extracted steam at heater pressure; h_fw,in is feedwater enthalpy entering heater; h_fw,out is saturated liquid enthalpy at heater pressure. kJ/kg units.

  • Reheat turbine total work: w_t,total = (h1 − h2) + (1 − y) · (h3 − h4) For a single reheat with one extraction before reheat (if extraction is taken at the reheat pressure from HP turbine exit). kJ/kg.

  • Total heat added with reheat and one extraction at reheat pressure: q_in = (h1 − h8) + (1 − y) · (h3 − h2) h8 is feedwater enthalpy at boiler inlet after final pump; kJ/kg.

  • Pump work sums (two pumps around one OFWH): w_p,total = w_p,LP + w_p,HP ≈ v · (p_ex − p_c) + v · (p_b − p_ex) With v ≈ 0.001 m³/kg for water near ambient; p_ex = extraction pressure, p_c = condenser pressure, p_b = boiler pressure; work in kJ/kg.

Worked examples

Example 1 — Direct: Simple Rankine (ideal) with superheat Given data (from steam tables; verify values for the chosen states):

  • Boiler outlet (turbine inlet): p1 = 10 MPa, T1 = 480 °C, h1 = 3375 kJ/kg, s1 = 6.60 kJ/kg·K.
  • Condenser pressure: p_c = 10 kPa. Saturated properties at 10 kPa: h_f = 191.8 kJ/kg, h_g = 2584.7 kJ/kg, h_fg = 2392.9 kJ/kg, s_f = 0.476 kJ/kg·K, s_g = 8.146 kJ/kg·K, s_fg = 7.670 kJ/kg·K.
  • Pump and turbine are isentropic. Neglect pressure drops in boiler/condenser. v_f at 10 kPa ≈ 0.001 m³/kg.

Find: η_th, w_net, SSC, exit quality.

Steps:

  1. Turbine isentropic expansion to p_c: s2s = s1 = 6.60 kJ/kg·K. Compute quality at exit using s: x2s = (s2s − s_f)/s_fg = (6.60 − 0.476)/7.670 = 0.799 (dimensionless).

  2. Exit enthalpy: h2s = h_f + x2s · h_fg = 191.8 kJ/kg + 0.799 · 2392.9 kJ/kg = 2103.0 kJ/kg.

  3. Turbine work (ideal): w_t = h1 − h2s = 3375 − 2103.0 = 1272.0 kJ/kg.

  4. Pump work (ideal): w_p = v · (p_b − p_c) = 0.001 m³/kg · (10×10^6 − 10×10^3) Pa ≈ 10.0 kJ/kg. Then h4 ≈ h_f + w_p = 191.8 + 10.0 = 201.8 kJ/kg.

  5. Heat added: q_in = h1 − h4 = 3375 − 201.8 = 3173.2 kJ/kg.

  6. Net work: w_net = w_t − w_p = 1272.0 − 10.0 = 1262.0 kJ/kg.

  7. Thermal efficiency: η_th = w_net / q_in = 1262.0 / 3173.2 = 0.3978 = 39.78%.

  8. Specific steam consumption: SSC = 3600 / w_net = 3600 / 1262.0 = 2.854 kg/kWh.

  9. Exit quality already computed: x2s ≈ 0.799 (i.e., ~20.1% moisture) — quite wet, motivating reheat.

Answer: η_th = 39.8%, w_net = 1262.0 kJ/kg, SSC = 2.854 kg/kWh, turbine exit x ≈ 0.799 (wet; 20.1% moisture).

Assumptions: ideal pump and turbine; properties from standard steam tables (IAPWS-IF97 or equivalent). Small rounding differences are expected if a different table or interpolation is used.

Example 2 — GATE-level: Reheat with one open feedwater heater (OFWH), non-ideal turbines, ideal pumps Cycle layout: HP turbine → bleed at reheat pressure to an OFWH → reheat of remaining flow → LP turbine → condenser. Two pumps: LP pump to OFWH pressure, then HP pump to boiler pressure.

Given data (property values taken from tables for representative states; verify):

  • Main steam at HP turbine inlet: h1 = 3500 kJ/kg (p_b high), turbine HP isentropic exit enthalpy to reheat pressure: h2s = 3000 kJ/kg; HP turbine isentropic efficiency η_t,HP = 0.88.
  • Reheat pressure p_ex = 3 MPa; after reheat: h3 = 3600 kJ/kg.
  • LP turbine isentropic exit enthalpy to condenser pressure: h4s = 2100 kJ/kg; LP turbine isentropic efficiency η_t,LP = 0.88.
  • Condenser pressure p_c = 10 kPa; saturated liquid at condenser exit: h5 = 191.8 kJ/kg.
  • LP pump to OFWH pressure p_ex: w_p,LP = v · (p_ex − p_c) ≈ 0.001 m³/kg · (3×10^6 − 10×10^3) Pa ≈ 3.0 kJ/kg. So h6 ≈ 194.8 kJ/kg.
  • OFWH outlet is saturated liquid at p_ex with h7 ≈ 1000 kJ/kg (from steam tables at ~3 MPa; verify exact value).
  • HP pump to boiler pressure p_b = 12 MPa: w_p,HP ≈ 0.001 m³/kg · (12×10^6 − 3×10^6) Pa = 9.0 kJ/kg. So h8 ≈ 1009 kJ/kg at boiler inlet.

Find: extraction fraction y to OFWH, η_th, w_net, SSC, and LP exit quality.

Steps:

  1. HP turbine actual exit enthalpy (before reheat): Formula: h2a = h1 − η_t,HP · (h1 − h2s) Numbers: h2a = 3500 − 0.88 · (3500 − 3000) = 3500 − 0.88 · 500 = 3060 kJ/kg.

  2. Mass balance around OFWH: of 1 kg main steam, a fraction y goes to OFWH at h2a; (1 − y) goes to reheater and LP turbine.

  3. OFWH energy balance (adiabatic, direct-contact, single pressure): Formula: y · h_ex + (1 − y) · h_fw,in = h_fw,out Here, h_ex = h2a = 3060 kJ/kg; h_fw,in = h6 = 194.8 kJ/kg; h_fw,out = h7 = 1000 kJ/kg. Solve for y: y = (h_fw,out − h_fw,in)/(h_ex − h_fw,in) Numbers: y = (1000 − 194.8)/(3060 − 194.8) = 805.2/2865.2 = 0.281 (dimensionless).

  4. Reheat of remaining flow: Only (1 − y) = 0.719 kg is reheated from h2a to h3.

  5. LP turbine actual exit enthalpy: Formula: h4a = h3 − η_t,LP · (h3 − h4s) Numbers: h4a = 3600 − 0.88 · (3600 − 2100) = 3600 − 1320 = 2280 kJ/kg.

  6. Turbine work per kg main flow: HP stage: w_HP = h1 − h2a = 3500 − 3060 = 440 kJ/kg. LP stage: w_LP = (1 − y) · (h3 − h4a) = 0.719 · (3600 − 2280) = 0.719 · 1320 = 949.1 kJ/kg. Total: w_t = 440 + 949.1 = 1389.1 kJ/kg.

  7. Pump work per kg main flow: w_p,total = w_p,LP + w_p,HP = 3.0 + 9.0 = 12.0 kJ/kg.

  8. Net work: w_net = w_t − w_p,total = 1389.1 − 12.0 = 1377.1 kJ/kg.

  9. Heat added per kg main flow: Boiler: q_boiler = h1 − h8 = 3500 − 1009 = 2491 kJ/kg. Reheat (only the (1 − y) stream): q_reheat = (1 − y) · (h3 − h2a) = 0.719 · (3600 − 3060) = 0.719 · 540 = 388.3 kJ/kg. Total: q_in = 2491 + 388.3 = 2879.3 kJ/kg.

  10. Thermal efficiency: η_th = w_net / q_in = 1377.1 / 2879.3 = 0.478 ≈ 47.8%.

  11. Specific steam consumption: SSC = 3600 / w_net = 3600 / 1377.1 = 2.613 kg/kWh.

  12. LP turbine exit quality at p_c = 10 kPa: Using h4a = 2280 kJ/kg and saturation enthalpies at 10 kPa (h_f = 191.8, h_fg = 2392.9): x = (h4a − h_f)/h_fg = (2280 − 191.8)/2392.9 = 2088.2/2392.9 = 0.872 (moisture ≈ 12.8%).

Answer: y = 0.281, η_th ≈ 47.8%, w_net ≈ 1377.1 kJ/kg, SSC ≈ 2.613 kg/kWh, LP exit x ≈ 0.872.

Assumptions: as stated; property values (h1, h2s, h3, h4s, h7) are representative and must be taken from consistent steam tables for the specified pressures/temperatures. Small differences will change final digits.

Common mistakes

  • Forgetting to scale turbine work and reheat heat-addition by (1 − y) after an extraction in regeneration problems.
  • Omitting the second pump (from OFWH pressure to boiler pressure) in OFWH layouts, or forgetting its work.
  • Using saturated properties at the wrong pressure when computing quality (x) at turbine exit, or mixing s-based and h-based formulas inconsistently.
  • Assuming pump work is zero; it is small but not zero and matters in high-precision answers (e.g., η_th to one decimal place).
  • Treating reheat as raising pressure instead of (approximately) constant-pressure heating.
  • Not accounting for pressure drops in realistic problems when data include them (exam questions may specify boiler/condenser pressure drops explicitly).

For GATE ME

  • Direct cycle calculations: given pressures and temperatures (or enthalpies/entropies), compute w_t, w_p, q_in, η_th, SSC, heat rate, and exit quality.
  • Reheat cycle numericals: determine total turbine work (sum of stages), added reheat heat, and impact on η_th and exit moisture; may include isentropic efficiencies per stage.
  • Regenerative cycle numericals: single OFWH or CFWH; find extraction fraction(s) via mass and energy balances; compute η_th and SSC. Watch for cascaded drains in CFWH.
  • Combined reheat + regeneration: compute extraction at reheat pressure or another intermediate pressure and scale downstream flows correctly.
  • Conceptual questions: why reheat reduces moisture, why regeneration raises η_th, trade-offs with condenser pressure, boiler pressure/superheat limits, and back work ratio trends.
  • Optimization ideas: effect of number of heaters on η_th, indicative location of reheat pressure (geometric-mean heuristic for idealized models), and constraints due to moisture limits.
  • Practise: reading/interpolating steam tables; drawing T–s/h–s diagrams; setting up control-volume mass/energy balances with correct mass fractions.

Quick check

  1. Define turbine isentropic efficiency and state how you would compute the actual exit enthalpy from known h_in, h_out,is.
  2. In a cycle with one OFWH at pressure p_ex, which three enthalpies do you need to find the extraction fraction y, and what is the equation?
  3. Why does reheat generally improve the exit dryness fraction of the LP turbine?

Answers: (1) η_t = (h_in − h_out,act)/(h_in − h_out,is); so h_out,act = h_in − η_t · (h_in − h_out,is). (2) h_ex (extracted steam), h_fw,in (feedwater into heater), and h_fw,out (feedwater out of heater); y = (h_fw,out − h_fw,in)/(h_ex − h_fw,in). (3) Because reheating raises the steam temperature (and enthalpy) at the intermediate pressure before the LP expansion, reducing the fraction of the LP expansion that occurs in the two-phase region and thus increasing the dryness fraction at the final pressure.