Gas turbines (simple and combined-cycle power plants, aircraft engines) run on the Brayton cycle. Understanding how pressure ratio, turbine inlet temperature, regeneration, intercooling, and real component efficiencies shape efficiency and output lets you size, optimize, and troubleshoot real engines and answer exam/interview questions confidently.

Key ideas

  • Definition and model

    • The Brayton cycle is the gas-turbine power cycle with four ideal processes on an air-standard basis: 1→2 isentropic compression, 2→3 constant-pressure heat addition, 3→4 isentropic expansion, 4→1 constant-pressure heat rejection.
    • Air-standard assumption: working fluid is air throughout; combustion is replaced by external heat addition; exhaust is replaced by heat rejection. Cold-air-standard adds that cp and γ are constant.
    • Standard state numbering: 1 (compressor inlet), 2 (compressor exit), 3 (turbine inlet), 4 (turbine exit). Pressure ratio rp = p2/p1 = p3/p4.
    • Sign convention (cycles): turbine work output positive; compressor work input treated as positive magnitude; net work w_net = w_t − w_c; heat added q_in > 0 in heater; heat rejected q_out > 0 in cooler.
    • Assumptions for the ideal analysis unless stated: steady state, negligible kinetic/potential energy changes, internally reversible compression/expansion, no pressure drops in heat exchangers, ideal gas with constant cp and γ.
  • Thermodynamic bases

    • Steady Flow Energy Equation (SFEE), under negligible KE/PE: q̇ − ẇ = ṁ (h_out − h_in). For compressor and turbine, this links shaft work to enthalpy (temperature) change of an ideal gas.
    • Isentropic relations for ideal gas with constant γ: T2/T1 = (p2/p1)^((γ−1)/γ) and T3/T4 = (p3/p4)^((γ−1)/γ).
  • Cycle performance measures

    • Specific compressor work w_c = cp (T2 − T1).
    • Specific turbine work w_t = cp (T3 − T4).
    • Net specific work w_net = w_t − w_c.
    • Back work ratio (BWR) = w_c / w_t (typical 0.4–0.6 for simple gas turbines; high compared with steam plants).
    • Heat added q_in = cp (T3 − T2); heat rejected q_out = cp (T4 − T1).
    • Thermal efficiency η_th = w_net / q_in = 1 − q_out/q_in.
  • Result: ideal Brayton efficiency depends only on pressure ratio (cold-air-standard)

    • With isentropic 1→2 and 3→4 and equal pressure ratios: T2/T1 = T3/T4 = rp^a, where a = (γ−1)/γ.
    • Then q_in ∝ (T3 − T2) and q_out ∝ (T4 − T1). Because T3 = rp^a T4 and T2 = rp^a T1, (T3 − T2) = rp^a (T4 − T1). Hence q_out/q_in = 1/rp^a.
    • Standard result: η_th,ideal = 1 − 1/rp^a, with a = (γ−1)/γ. This is widely tested.
    • Implications: increasing rp raises efficiency (diminishing returns), but net work also depends on Tmax (material/cooling limits).
  • Optimum pressure ratio for maximum specific net work at fixed Tmin and Tmax (ideal)

    • Condition for maximum w_net is T2 = T4 (equal temperatures at the ends of the constant-pressure processes). This yields T2 = √(T1 T3).
    • Using T2/T1 = rp^a ⇒ rp,opt = (T3/T1)^(γ/[2(γ−1)]).
    • Physical meaning: splitting the available temperature span “evenly” across compressor rise and turbine drop maximizes net work.
  • Regeneration (recuperator)

    • Regenerator transfers heat from hot turbine exhaust (state 4) to the compressed air (state 2) before combustion, reducing required external heat input.
    • Effectiveness ε = (T5 − T2) / (T4 − T2), with T5 the air temperature leaving the regenerator toward combustor. For a regenerator with equal capacity rates on both sides (same ṁ and cp), T6 = T4 − (T5 − T2).
    • Thermal efficiency with a regenerator (still simple single-shaft cycle) becomes η_th = 1 − (T6 − T1) / (T3 − T5). Work output w_net is unchanged by regeneration.
    • Regeneration is beneficial only if T4 > T2. For the ideal Brayton with fixed T1, T3 this requires rp < (T3/T1)^(γ/[2(γ−1)]), the same threshold as rp,opt.
  • Real components: isentropic efficiencies and pressure losses

    • Compressor isentropic efficiency (based on temperature rise): η_c = (T2s − T1) / (T2a − T1), where s = isentropic, a = actual. Actual T2a > T2s, so actual compressor work is larger.
    • Turbine isentropic efficiency (based on temperature drop): η_t = (T3 − T4a) / (T3 − T4s). Actual T4a > T4s, so actual turbine work is smaller.
    • Typical γ for hot gases is lower than 1.4 (often 1.33–1.35 at high T); cp increases with temperature. Cold-air-standard (γ constant) is an approximation; using temperature-dependent properties is more accurate (but rarely required in GATE numericals unless stated).
    • Combustor and regenerator pressure drops reduce effective pressure ratio across turbine and compressor, reducing w_net and η_th.
  • Cycle improvements (mentioned, tested conceptually)

    • Intercooling during multi-stage compression reduces compressor work. With perfect intercooling back to T1, minimum compressor work occurs when pressure ratio is split equally per stage: (p2/p1) = (p3/p2) = √rp for two stages (general: rp^(1/n) per stage).
    • Reheating during multi-stage expansion increases turbine work. Maximum turbine work for given p3/p4 with two stages also results from equal pressure ratio per stage.
    • Intercooling + reheat + regeneration: increases specific work and can raise efficiency (via regeneration); the ideal limit approaches a rectangular T–s box between T1 and T3, but real limits and added losses apply.
  • Why real devices differ from ideal

    • Non-isentropic compression/expansion (η_c < 1, η_t < 1), pressure losses in heat exchangers and ducts, finite regenerator effectiveness ε < 1, variable properties (γ, cp), blade cooling and bleed flows, mechanical and generator/gearbox losses. These reduce w_net and η_th compared with the ideal model.

Formulas

rp = p2 / p1 = p3 / p4 — pressure ratio across compressor (dimensionless), ideal simple Brayton with no pressure losses in heater/cooler.

a = (γ − 1) / γ — exponent in isentropic ideal-gas relations (dimensionless); γ = cp/cv.

T2 / T1 = rp^a — isentropic compressor temperature relation (K), ideal gas, constant γ.

T3 / T4 = rp^a — isentropic turbine temperature relation (K), ideal gas, constant γ.

w_c = cp (T2 − T1) — specific compressor work input (kJ/kg), steady flow, ideal gas; cp in kJ/(kg·K), T in K.

w_t = cp (T3 − T4) — specific turbine work output (kJ/kg), steady flow, ideal gas.

w_net = w_t − w_c — specific net work of the cycle (kJ/kg), positive for power cycle.

q_in = cp (T3 − T2) — specific heat added in the combustor/heater (kJ/kg), ideal gas at constant pressure.

q_out = cp (T4 − T1) — specific heat rejected in the cooler (kJ/kg), ideal gas at constant pressure.

η_th = 1 − q_out / q_in — thermal efficiency of the cycle (dimensionless), definition.

η_th,ideal = 1 − 1 / rp^a — ideal Brayton efficiency (dimensionless), cold-air-standard, isentropic compressor/turbine, no pressure losses.

BWR = w_c / w_t — back work ratio (dimensionless); typical 0.4–0.6 in simple gas turbines.

rp,opt = (T3 / T1)^(γ / [2(γ − 1)]) — pressure ratio for maximum w_net at fixed T1 and T3, ideal.

ε = (T5 − T2) / (T4 − T2) — regenerator effectiveness (dimensionless), equal capacity rates assumed; T5 is air temperature after regenerator.

T6 = T4 − (T5 − T2) — regenerator hot-exit temperature (K), equal capacity rates.

η_th,regen = 1 − (T6 − T1) / (T3 − T5) — thermal efficiency with regeneration (dimensionless), simple regenerative Brayton.

η_c = (T2s − T1) / (T2a − T1) — compressor isentropic efficiency (dimensionless); s=isotropic, a=actual.

η_t = (T3 − T4a) / (T3 − T4s) — turbine isentropic efficiency (dimensionless).

SFEE (steady, negligible KE/PE): q̇ − ẇ = ṁ (h_out − h_in) — steady-flow energy equation; here h ≈ cp T for ideal gas.

R = cp − cv and γ = cp / cv — ideal-gas relations; for air near 300 K, R ≈ 0.287 kJ/(kg·K), cp ≈ 1.004–1.005 kJ/(kg·K).

T4 > T2 ⇒ rp < (T3/T1)^(γ / [2(γ − 1)]) — condition under which regeneration is beneficial (dimensionless inequality), ideal assumptions.

(p2/p1) = (p3/p2) = √rp — equal pressure split per stage for 2-stage compression/expansion to minimize/maximize stage work (dimensionless), ideal, with perfect intercooling/reheat respectively.

Worked examples

Example 1 — Direct application (ideal Brayton) Given: Air-standard, cold-air-standard Brayton cycle; T1 = 300 K; T3 = 1400 K; pressure ratio rp = 8; γ = 1.4; cp = 1.004 kJ/(kg·K). Find T2, T4, w_c, w_t, w_net, η_th, BWR.

Steps:

  1. Isentropic compressor: formula: T2 = T1 · rp^a; with a = (γ − 1)/γ = 0.4/1.4 = 0.285714. Numbers: T2 = 300 K · 8^0.285714 ≈ 300 · 1.811 = 543.3 K.
  2. Isentropic turbine: formula: T4 = T3 / rp^a. Numbers: T4 = 1400 K / 1.811 ≈ 773.4 K.
  3. Compressor work: formula: w_c = cp (T2 − T1). Numbers: w_c = 1.004 kJ/(kg·K) · (543.3 − 300) K = 1.004 · 243.3 = 244.27 kJ/kg.
  4. Turbine work: formula: w_t = cp (T3 − T4). Numbers: w_t = 1.004 · (1400 − 773.4) = 1.004 · 626.6 = 629.10 kJ/kg.
  5. Net work: formula: w_net = w_t − w_c. Numbers: w_net = 629.10 − 244.27 = 384.83 kJ/kg.
  6. Heat added: formula: q_in = cp (T3 − T2). Numbers: q_in = 1.004 · (1400 − 543.3) = 1.004 · 856.7 = 860.13 kJ/kg.
  7. Efficiency: formula: η_th = w_net / q_in. Numbers: η_th = 384.83 / 860.13 = 0.447 ≈ 44.7%. Check with η_th,ideal = 1 − 1/rp^a = 1 − 1/1.811 = 0.448 (matches within rounding).
  8. Back work ratio: formula: BWR = w_c / w_t. Numbers: BWR = 244.27 / 629.10 = 0.388.

Answer: w_net = 384.8 kJ/kg, η_th = 44.7%, BWR = 0.388.

Example 2 — GATE-level (regeneration + non-ideal compressor/turbine) Given: Regenerative Brayton cycle. T1 = 300 K, T3 = 1300 K, rp = 6, compressor isentropic efficiency η_c = 0.85, turbine isentropic efficiency η_t = 0.88, regenerator effectiveness ε = 0.75. Assume γ = 1.4 (a = 0.285714), cp = 1.004 kJ/(kg·K), no pressure losses in heat exchangers. Find: T2a, T4a, T5, T6, w_c, w_t, w_net, q_in, η_th.

Steps:

  1. Ideal (s) compressor exit temperature: formula: T2s = T1 · rp^a. Numbers: T2s = 300 · 6^0.285714 ≈ 300 · 1.668 = 500.4 K.
  2. Actual compressor exit: formula: η_c = (T2s − T1) / (T2a − T1) ⇒ T2a = T1 + (T2s − T1)/η_c. Numbers: T2a = 300 + (500.4 − 300)/0.85 = 300 + 200.4/0.85 = 300 + 235.76 = 535.77 K.
  3. Ideal (s) turbine exit: formula: T4s = T3 / rp^a. Numbers: T4s = 1300 / 1.668 = 779.4 K.
  4. Actual turbine exit: formula: η_t = (T3 − T4a) / (T3 − T4s) ⇒ T4a = T3 − η_t (T3 − T4s). Numbers: T4a = 1300 − 0.88 · (1300 − 779.4) = 1300 − 0.88 · 520.6 = 1300 − 458.13 = 841.87 K.
  5. Regenerator outlet to combustor: formula: T5 = T2a + ε (T4a − T2a) (capacity rates equal). Numbers: T5 = 535.77 + 0.75 · (841.87 − 535.77) = 535.77 + 229.58 = 765.35 K. Check: T5 ≤ T4a (765.35 < 841.87), OK.
  6. Regenerator outlet to exhaust: formula: T6 = T4a − (T5 − T2a) = (1 − ε) T4a + ε T2a. Numbers: T6 = 841.87 − (765.35 − 535.77) = 841.87 − 229.58 = 612.29 K.
  7. Works and heats:
    • Compressor work: w_c = cp (T2a − T1) = 1.004 · (535.77 − 300) = 236.73 kJ/kg.
    • Turbine work: w_t = cp (T3 − T4a) = 1.004 · (1300 − 841.87) = 459.96 kJ/kg.
    • Net work: w_net = w_t − w_c = 223.23 kJ/kg.
    • Heat added: q_in = cp (T3 − T5) = 1.004 · (1300 − 765.35) = 536.79 kJ/kg.
    • Heat rejected (check): q_out = cp (T6 − T1) = 1.004 · (612.29 − 300) = 313.54 kJ/kg.
  8. Efficiency: formula: η_th = w_net / q_in = 1 − q_out/q_in. Numbers: η_th = 223.23 / 536.79 = 0.416 ≈ 41.6%; also 1 − 313.54/536.79 = 0.416 (consistent).
  9. Back work ratio (optional): BWR = w_c / w_t = 236.73 / 459.96 = 0.515.

Answer: w_net = 223.2 kJ/kg, η_th = 41.6%, BWR = 0.515.

Assumptions restated for both examples: steady flow; negligible KE/PE; ideal gas with constant cp, γ; no mechanical losses; for Example 2, no pressure loss in heat exchangers; regenerator capacity rates equal on hot/cold sides.

Common mistakes

  • Mixing Celsius and Kelvin. Always use absolute temperatures (K) in thermodynamic ratios and differences.
  • Using η_th = 1 − 1/rp^a when component efficiencies are given. That formula is only for ideal isentropic compressor/turbine with constant γ.
  • Applying γ = 1.4 and cp for cold air at all temperatures without being told; at high T, γ decreases and cp increases. In exams, use given/standard values; in design, use temperature-dependent properties.
  • Forgetting T5 ≤ T4 in regeneration. If your ε formula gives T5 > T4, cap T5 at T4 (or recompute with the correct definition using C_min/C_max if capacity rates differ).
  • Misdefining η_c and η_t (inverting the ratios). Remember: η_c = (ideal rise)/(actual rise); η_t = (actual drop)/(ideal drop).
  • Ignoring pressure losses in combustor/regenerator when the problem states them; they reduce effective rp across turbine and compressor.
  • Confusing net work w_net with turbine work w_t (forgetting to subtract compressor work).
  • Not checking the regeneration-benefit condition T4 > T2; adding a regenerator in a high-rp cycle can be pointless in theory problems.

For GATE ME

  • Rapid computation of ideal Brayton cycle: given rp and γ, find η_th quickly via η_th = 1 − 1/rp^a; compute T2, T4 using isentropic relations.
  • Non-ideal analysis: use η_c and η_t definitions to find T2a and T4a, then w_c, w_t, w_net, and η_th. Be fluent with rearrangements.
  • Regeneration: apply ε and check T5 ≤ T4; compute η_th,regen via either w/q or 1 − q_out/q_in. Know when regeneration helps (T4 > T2).
  • Optimization concepts: derive or recall rp,opt = (T3/T1)^(γ/[2(γ−1)]) for maximum w_net at fixed T1, T3; understand the physical condition T2 = T4.
  • Intercooling/reheat pressure split: equal pressure ratios per stage minimize/raise stage work. Expect conceptual or short numericals.
  • Back work ratio: estimate magnitude and trends with rp and non-idealities.
  • Practise problems combining: given T1, T3, rp, η_c, η_t, ε → compute temperatures, works, heats, and efficiency in fewer than 10 steps.

Quick check

  1. In an ideal Brayton cycle with γ = 1.4 and rp = 12, what is η_th?
  2. State the condition under which a regenerator is theoretically beneficial in the Brayton cycle.
  3. For two-stage compression with perfect intercooling from T1 back to T1, how should you split the overall pressure ratio for minimum compressor work?

Answers: (1) η_th = 1 − 1/rp^a = 1 − 1/12^0.2857 ≈ 1 − 1/2.02 ≈ 0.505 (≈50.5%); (2) When T4 > T2, equivalently rp < (T3/T1)^(γ/[2(γ−1)]), under ideal assumptions; (3) Equally per stage: p2/p1 = p3/p2 = √rp.