UV–Visible and IR spectroscopy: principles, laws (Beer–Lambert), selection rules, instrumentation, spectra interpretation, and applications with worked numericals.

Drafted with Aria, reviewed by the AiCanCode.org team · Updated . How we write and check our notes. Spotted an error? Use Give Feedback at the bottom of the page.

Why it matters

Engineers use UV–Visible and Infrared (IR) spectroscopy to identify materials, check purity, monitor reactions, and control quality in polymers, pharmaceuticals, fuels, coatings, semiconductors, and environmental samples. These tools give fast, non-destructive, and quantitative information about electronic and molecular structure.

Key ideas

  • UV–Visible region: approximately 200–800 nm (UV: 200–400 nm; Visible: 400–800 nm).

  • Infrared region: approximately 2.5–25 μm i.e., 4000–400 cm⁻¹ (mid-IR commonly used in chemistry).

  • Electronic transitions (UV–Visible): Electrons in molecules move between energy levels when they absorb photons. Common transitions:

    • π → π: from a bonding π orbital to an antibonding π orbital (strong, allowed; high intensity).
    • n → π: from a nonbonding n orbital (lone pair) to π (often weaker; partly forbidden).
    • Energy differences determine λmax (wavelength of maximum absorbance). Conjugation (alternating multiple bonds) lowers the energy gap, leading to longer wavelengths (red-shift).
  • Vibrational transitions (IR): Atoms in molecules vibrate (stretching, bending). IR light is absorbed when the vibration changes the dipole moment of the molecule.

    • Selection rule (IR): A vibrational mode is IR-active if it involves a change in dipole moment (Δμ ≠ 0). Fundamental transitions follow Δv = ±1 (where v is vibrational quantum number) for a harmonic oscillator approximation; real molecules show overtones (Δv = ±2, ±3, …) with lower intensity due to anharmonicity.
    • Approximate vibrational frequency is set by bond strength (force constant) and reduced mass.
  • Beer–Lambert law (UV–Visible): Relates absorbance to concentration for a homogeneous, non-scattering solution under monochromatic light: A = ε·l·c, where A is absorbance, ε is molar absorptivity, l is path length, c is concentration. Assumes no chemical interaction changing ε, and linear response.

  • Definitions (UV–Visible terms):

    • Transmittance (T): T = I/I₀, fraction of incident light (I₀) transmitted (I).
    • Absorbance (A): A = −log₁₀ T; dimensionless and additive with path length and concentration.
    • Molar absorptivity (ε): proportionality constant in Beer–Lambert law (commonly quoted in L·mol⁻¹·cm⁻¹; SI-consistent form uses m²·mol⁻¹ with path length in m).
    • Chromophore: the part of a molecule responsible for light absorption (e.g., C=C, C=O, N=N, aromatic ring).
    • Auxochrome: a substituent that, when attached to a chromophore, modifies its absorption (e.g., –OH, –NH₂), often increasing intensity (hyperchromic) or shifting λmax.
    • Bathochromic shift (red shift): absorption moves to longer λ (lower energy) due to conjugation, solvent polarity, or substituent effects.
    • Hypsochromic shift (blue shift): absorption moves to shorter λ.
    • Hyperchromic effect: increased absorbance intensity (higher ε).
    • Hypochromic effect: decreased absorbance intensity.
  • Definitions (IR terms):

    • Wavenumber (ṽ): reciprocal wavelength; ṽ = 1/λ (in m⁻¹; commonly reported in cm⁻¹ in IR). Proportional to energy.
    • Functional group region: ~4000–1500 cm⁻¹; shows characteristic group absorptions (e.g., O–H, N–H, C=O, C≡N).
    • Fingerprint region: ~1500–400 cm⁻¹; complex pattern unique to each molecule, useful for identification.
  • Approximate group frequencies (mid-IR, cm⁻¹):

    • O–H stretch (alcohol): broad ~3200–3600; (acid): very broad ~2500–3300
    • N–H stretch: ~3300–3500 (often sharper than O–H)
    • C–H stretch: sp³ ~2850–2960; sp² ~3010–3100; sp ~3300 (sharp)
    • C≡C: ~2100–2260 (weak); C≡N: ~2210–2260
    • C=O: ~1650–1750 (ketone ~1715; aldehyde ~1720–1740; ester ~1735–1750; amide ~1630–1690; acid ~1700–1725)
    • C=C (alkene): ~1620–1680; aromatic C=C: ~1450–1600
  • Derivations commonly asked:

    1. Beer–Lambert law:

      • For a thin layer dx, decrease in intensity dI is proportional to intensity and concentration: dI ∝ −c·I·dx.
      • Write dI = −κ·c·I·dx, integrate from I₀ at x=0 to I at x=l: ∫(I₀→I) dI/I = −κ·c ∫(0→l) dx.
      • ln(I/I₀) = −κ·c·l. Convert to base-10 logarithm: A = −log₁₀(I/I₀) = (κ/2.303)·c·l = ε·l·c.
      • Assumptions: monochromatic light, dilute solution, non-interacting absorbing species, no scattering or fluorescence, constant ε over the band.
    2. Vibrational frequency of a diatomic (Hooke’s-law model):

      • Two masses m₁ and m₂ connected by a spring (force constant k) vibrate with angular frequency ω = √(k/μ), where μ = m₁m₂/(m₁ + m₂) is reduced mass.
      • Frequency ν = ω/(2π) = (1/2π)·√(k/μ).
      • Wavenumber ṽ = ν/c = (1/2πc)·√(k/μ).
      • Assumptions: harmonic oscillator, no rotation–vibration coupling, isolated bond.
  • Selection rules and intensities:

    • UV–Visible: Laporte rule (for centrosymmetric molecules, g → g and u → u transitions are forbidden; π → π* often allowed, n → π* partially forbidden). Spin selection rule: ΔS = 0 (spin-forbidden transitions are weak).
    • IR: Mode must change dipole moment; symmetric diatomic molecules (e.g., N₂, O₂) are IR-inactive.
  • Instrumentation essentials:

    • UV–Visible Spectrophotometer (draw a block diagram):
      • Describe: Light source(s) (Deuterium lamp for UV ~190–350 nm; Tungsten–halogen lamp for visible ~350–800 nm) → Entrance slit → Monochromator (prism or grating) → Exit slit → Sample cell (quartz cuvette for UV; glass ok only for visible) → Detector (photodiode or photomultiplier tube) → Signal processor/display.
      • In a double-beam instrument, add a beam splitter and reference path with solvent to correct baseline.
    • IR Spectrometer (FTIR preferred) (draw a block diagram):
      • Describe: Broadband IR source (Globar SiC rod) → Michelson interferometer (beam splitter, fixed mirror, moving mirror) → Sample compartment (transmission cell/KBr pellet/ATR crystal) → Detector (DTGS or MCT) → Computer for Fourier Transform to convert interferogram to spectrum.
      • For dispersive IR, replace interferometer with monochromator; less common now.
    • Sample handling:
      • UV–Visible: Solutions in matched 1 cm quartz cuvettes for UV; avoid bubbles and fingerprints; baseline with solvent.
      • IR: Solids as KBr pellets; liquids as neat film between NaCl/KBr windows; ATR allows direct measurement with minimal prep.
  • Applications:

    • UV–Visible: concentration determination (Beer–Lambert), reaction kinetics (time-dependent A), band gap estimation in semiconductors (Tauc plots in materials labs—advanced), color quality control in dyes/coatings, nitrate/nitrite analysis in water.
    • IR: identification of functional groups and polymer backbones, monitoring curing of resins, detection of contamination or degradation (e.g., oxidation via C=O growth), verification of fuel additives.
  • Limitations and deviations:

    • Beer–Lambert deviations: high concentration (solute–solute interactions), chemical equilibria changing ε, polychromatic light, stray light, scattering (turbidity), fluorescence or phosphorescence, instrument nonlinearity.
    • IR limitations: overlapping bands in complex mixtures, weak bands for symmetric stretches, strong solvent absorption in some regions.

Formulas

  • A = ε · l · c — Beer–Lambert law; ε: molar absorptivity (L·mol⁻¹·cm⁻¹ commonly; SI-consistent: m²·mol⁻¹), l: path length (cm commonly; SI: m), c: concentration (mol·L⁻¹ commonly; SI: mol·m⁻³). Valid for dilute, non-scattering, monochromatic conditions.
  • ε = A / (l · c) — Determine molar absorptivity from slope of A vs c at fixed l.
  • ν = (1 / 2π) · √(k / μ) — Vibrational frequency; ν: s⁻¹, k: bond force constant (N·m⁻¹), μ: reduced mass (kg); harmonic oscillator.
  • ṽ = (1 / (2π · c)) · √(k / μ) — Vibrational wavenumber; ṽ: m⁻¹ (commonly reported in cm⁻¹), c: speed of light (m·s⁻¹).
  • μ = (m1 · m2) / (m1 + m2) — Reduced mass; m1, m2: kg.
  • ln(I / I0) = -κ · c · l — Exponential attenuation form (κ: absorption coefficient, m²·mol⁻¹ if c in mol·m⁻³); leads to Beer–Lambert after base change.
  • ln(A_t / A_0) = -k · t — For first-order kinetics monitored by UV–Visible when A ∝ concentration; k: s⁻¹, t: s; valid if ε and l constant.

Worked examples

  1. UV–Visible concentration from absorbance

    • Given: A(500 nm) = 0.600 for a solution in a 1.00 cm cuvette. ε(500 nm) = 1.50 × 10⁴ L·mol⁻¹·cm⁻¹. Find c.
    • Steps:
      1. Use Beer–Lambert law: A = ε·l·c.
      2. Rearrange: c = A/(ε·l).
      3. Substitute: c = 0.600 / [(1.50 × 10⁴ L·mol⁻¹·cm⁻¹) × (1.00 cm)].
      4. Compute: c = 0.600 / (1.50 × 10⁴) mol·L⁻¹ = 4.00 × 10⁻⁵ mol·L⁻¹.
      5. Convert to SI if needed: 4.00 × 10⁻⁵ mol·L⁻¹ = 4.00 × 10⁻⁵ mol·dm⁻³ = 0.0400 mol·m⁻³.
    • Answer: c = 4.00 × 10⁻⁵ mol·L⁻¹ (0.0400 mol·m⁻³).
  2. IR: Calculate bond force constant from band position (HCl)

    • Given: Fundamental IR absorption of gaseous HCl at ṽ = 2886 cm⁻¹. Atomic masses: H = 1.00784 u, Cl = 35.453 u. 1 u = 1.66054 × 10⁻²⁷ kg. c = 2.9979 × 10⁸ m·s⁻¹. Find force constant k.
    • Steps:
      1. Convert ṽ to SI (m⁻¹): 2886 cm⁻¹ = 2886 × 100 m⁻¹ = 2.886 × 10⁵ m⁻¹.
      2. Compute reduced mass μ in kg: μ = (m_H · m_Cl)/(m_H + m_Cl) in atomic mass units, then to kg.
        • μ(u) = (1.00784 × 35.453) / (1.00784 + 35.453) = 35.73 / 36.46084 ≈ 0.980 u.
        • μ(kg) = 0.980 × 1.66054 × 10⁻²⁷ ≈ 1.628 × 10⁻²⁷ kg.
      3. Use ṽ = (1/2πc)·√(k/μ) → k = (2πcṽ)² · μ.
      4. Compute 2πcṽ: 2π × (2.9979 × 10⁸) × (2.886 × 10⁵) ≈ 6.2832 × 8.660 × 10¹³ ≈ 5.436 × 10¹⁴ s⁻¹.
      5. Square: (5.436 × 10¹⁴)² ≈ 2.954 × 10²⁹ s⁻².
      6. Multiply by μ: k ≈ 2.954 × 10²⁹ × 1.628 × 10⁻²⁷ ≈ 4.81 × 10² N·m⁻¹.
    • Answer: k ≈ 4.81 × 10² N·m⁻¹.
  3. UV–Visible kinetics: first-order rate constant from absorbance decay

    • Given: A₀ = 1.200 at t = 0; A_t = 0.300 at t = 10.0 min for a reaction where absorbance is proportional to concentration. Find k in s⁻¹.
    • Steps:
      1. For first-order: ln(A_t/A₀) = −k·t (ε and l constant).
      2. Convert time: 10.0 min = 600 s.
      3. Compute ratio: A_t/A₀ = 0.300/1.200 = 0.250.
      4. Take natural log: ln(0.250) = −1.3863.
      5. Solve: −1.3863 = −k × 600 → k = 1.3863 / 600 s⁻¹ = 2.3105 × 10⁻³ s⁻¹.
    • Answer: k = 2.31 × 10⁻³ s⁻¹ (equivalently 0.1386 min⁻¹).

Common mistakes

  • Using glass cuvettes in the UV region (<350 nm) leading to strong absorption by the cuvette itself.
  • Ignoring baseline/reference corrections (solvent, cell) in UV–Visible and IR.
  • Misidentifying IR peaks by looking only at one band; always confirm with multiple, consistent group frequencies and the fingerprint region.
  • Assigning IR peaks without considering hydrogen bonding broadening (O–H, N–H) or overtone/combination bands.
  • Forgetting that symmetric nonpolar diatomics (N₂, O₂) are IR-inactive.
  • Confusing bathochromic (red) vs hypsochromic (blue) shifts; and hyperchromic vs hypochromic effects.

For your exam

  • Short notes: selection rules (UV–Visible and IR), common UV–Visible electronic transitions, conjugation effects, sample preparation (UV cuvettes; IR KBr pellet and ATR), FTIR vs dispersive IR, double-beam UV–Visible advantages.
  • Diagrams: labeled block diagrams of a double-beam UV–Visible spectrophotometer and an FTIR (Michelson interferometer with source, beam splitter, moving mirror, detector, computer).
  • Numericals: concentration from A (Beer–Lambert); ε from slope; rate constant from time-dependent A; IR force constant from ṽ; reduced mass calculations.
  • Interpretation: assign key IR bands for given functional groups; predict UV–Visible shifts due to conjugation or substituents.
  • Full-marks answers: precise definitions, correct units, clean derivations with assumptions stated, neat diagram labels, calculations with steps, units throughout, and final answers clearly highlighted.

Quick check

  1. State the Beer–Lambert law and its assumptions.
  2. Why is O₂ IR-inactive but CO IR-active?
  3. An absorption band moves from 260 nm to 290 nm after adding –OH to a benzene ring. Name the shift and effect on energy.

Answers: 1) A = ε·l·c; assumes monochromatic light, dilute solution, constant ε, no scattering/fluorescence, and non-interacting species. 2) O₂ has a symmetric vibration with no change in dipole moment; CO has a permanent dipole and its vibration changes dipole moment, so it is IR-active. 3) Bathochromic (red) shift; energy decreases.

Finished this topic? Mark it so your progress, study plan and readiness keep up.

Stuck on something here?