Batteries and fuel cells

Defines and explains primary/secondary batteries, battery ratings and reactions (dry cell, alkaline, lead–acid, Ni–Cd, Li‑ion), fuel cells (H2–O2 PEM and other types), Nernst/ΔG–E relations, polarization/efficiency, with formulas, derivations, diagrams-to-draw, and worked numericals.

Drafted with Aria, reviewed by the AiCanCode.org team · Updated . How we write and check our notes. Spotted an error? Use Give Feedback at the bottom of the page.

Why it matters

Key ideas

  • Galvanic (voltaic) cell: A spontaneous cell that produces electricity from a spontaneous reaction (ΔG < 0).
  • Electrolyte: An ionic conductor (liquid, gel, or solid) that allows ion movement to maintain charge balance; it does not allow significant electron flow.
  • Electrode: A solid electronic conductor where redox occurs. The anode is where oxidation occurs; the cathode is where reduction occurs. In a galvanic cell, anode is negative; cathode is positive.
  • Cell potential (emf, E): The driving force for electron flow; difference in electrode potentials between cathode and anode under specified conditions.
  • Open-circuit voltage (OCV): Cell voltage at zero current; equals the reversible potential predicted by thermodynamics (Nernst equation) under ideal conditions.
  • Internal resistance (r): Effective resistance inside the cell due to ionic/electronic resistances and charge-transfer; causes voltage drop under load.
  • Primary battery: Non-rechargeable; reactions are not easily reversible (e.g., Zn–MnO₂ dry cell, alkaline cell).
  • Secondary battery: Rechargeable; reactions are reversed during charging (e.g., lead–acid, Ni–Cd, Ni–MH, Li‑ion).
  • Fuel cell: An electrochemical device that continuously converts fuel and oxidant (supplied from outside) into electricity, heat, and products; does not store significant energy itself.
  • Capacity (Q): Total charge a battery can deliver from full to cutoff, usually in ampere-hour (A·h) or coulomb (C). Specific capacity in mA·h·g⁻¹. Related to the amount of active material.
  • Energy and power: Energy (J or W·h) = integral of voltage × current × time. Power (W) = voltage × current. Energy density (W·h·kg⁻¹) and power density (W·kg⁻¹) compare technologies.
  • C-rate: Rate normalized to capacity; 1C discharges in 1 h, 0.5C in 2 h.
  • State of charge (SoC): Remaining capacity as a percentage of full.
  • Depth of discharge (DoD): Fraction of capacity removed relative to nominal full.
  • Coulombic efficiency: Ratio of discharge charge to charge input in a full cycle.
  • Polarization (overpotential): Extra voltage beyond reversible value required to drive current; includes activation, ohmic, and concentration components.

Exact statements and derivations commonly asked:

  1. Relation between Gibbs free energy and cell potential
  • Statement: For an electrochemical reaction involving transfer of n moles of electrons at cell potential E (reversible, isothermal), the change in Gibbs free energy is ΔG = −n·F·E, where F is Faraday constant (96485 C·mol⁻¹). Assumptions: reversible operation, isothermal, pressure as defined by standard state; activities represent species.
  • Derivation (sketch): Electrical work done reversibly by a cell is W_elec,rev = ∫ E dq = E·q for constant E. For n moles of electrons, q = n·F. Maximum non-expansion work equals decrease in Gibbs free energy: W_max = −ΔG. Therefore, −ΔG = E·n·F ⇒ ΔG = −n·F·E.
  1. Nernst equation (university-standard form)
  • Statement: The electrode (or cell) potential under non-standard conditions is E = E° − (R·T)/(n·F) ln Q, where E° is standard potential (activities at standard state), Q is reaction quotient in terms of activities, n is electrons transferred. Assumptions: ideal behavior or activities known; temperature uniform; reversible (equilibrium at electrode surfaces).
  • Derivation (steps): From ΔG = ΔG° + R·T ln Q and ΔG = −n·F·E, combine to get −n·F·E = −n·F·E° + R·T ln Q ⇒ E = E° − (R·T)/(n·F) ln Q.
  1. Fuel-cell maximum (thermodynamic) efficiency
  • Statement: The maximum (reversible) efficiency of a fuel cell is η_max = ΔG/ΔH = E_rev/E_th, where E_rev = −ΔG/(n·F) and E_th = −ΔH/(n·F) (thermal voltage). Assumptions: no heat or entropy production (reversible), product and reactant activities at specified standard states.
  • For H₂–O₂ to liquid water at 25 °C, ΔG° ≈ −237.13 kJ·mol⁻¹, ΔH° ≈ −285.83 kJ·mol⁻¹; hence E_rev ≈ 1.229 V, E_th ≈ 1.481 V, η_max ≈ 0.83.
  1. Polarization and Tafel equation
  • Statement: At sufficiently high overpotential where activation control dominates, η_act = a + b·log₁₀ i with b = 2.303·R·T/(α·n·F), where α is charge-transfer coefficient (0<α<1). Assumptions: single rate-determining electron-transfer step, Butler–Volmer kinetics, |η| large enough to neglect reverse exponential term.

Typical cells and reactions you should know:

  • Leclanché dry cell (Zn–MnO₂, NH₄Cl/ZnCl₂ paste): Anode (zinc can) oxidizes: Zn → Zn²⁺ + 2e⁻ (complexed by Cl⁻). Cathode (carbon rod with MnO₂ depolarizer) reduces MnO₂ approximately to MnO(OH)/Mn₂O₃ in acidic medium. Overall (approximate): Zn + 2MnO₂ + 2NH₄Cl → ZnCl₂ + Mn₂O₃ + 2NH₃ + H₂O. Notes: non-rechargeable; voltage ~1.5 V nominal.
  • Alkaline Zn–MnO₂ (KOH): Better conductivity and utilization. Approximate overall: Zn + 2MnO₂ → ZnO + Mn₂O₃ (in KOH). Nominal ~1.5 V.
  • Lead–acid accumulator (H₂SO₄ aqueous): Discharge: Anode (Pb): Pb + SO₄²⁻ → PbSO₄ + 2e⁻. Cathode (PbO₂): PbO₂ + 4H⁺ + SO₄²⁻ + 2e⁻ → PbSO₄ + 2H₂O. Net: Pb + PbO₂ + 2H₂SO₄ → 2PbSO₄ + 2H₂O. Recharge reverses these. Nominal ~2.0 V per cell (OCV of fully charged around 2.1 V at 25 °C).
  • Nickel–cadmium (Ni–Cd, KOH): Discharge anode (Cd): Cd + 2OH⁻ → Cd(OH)₂ + 2e⁻. Cathode (NiOOH): 2NiO(OH) + 2H₂O + 2e⁻ → 2Ni(OH)₂ + 2OH⁻. Net: Cd + 2NiO(OH) + 2H₂O → Cd(OH)₂ + 2Ni(OH)₂. Nominal ~1.2 V; robust but Cd is toxic.
  • Nickel–metal hydride (Ni–MH): Similar cathode as Ni–Cd; anode is hydrogen-absorbing alloy (MH): MH + OH⁻ → M + H₂O + e⁻. Net with NiOOH gives nominal ~1.2 V.
  • Lithium‑ion (intercalation, organic electrolyte): Discharge anode (graphite): Li_xC₆ → C₆ + xLi⁺ + x e⁻. Cathode (example LiCoO₂): Li_{1−x}CoO₂ + xLi⁺ + x e⁻ → LiCoO₂. Net moves Li⁺ from anode to cathode. Nominal ~3.6–3.7 V per cell; high energy density.
  • PEM H₂–O₂ fuel cell (polymer electrolyte membrane): Anode: H₂ → 2H⁺ + 2e⁻. Cathode: ½O₂ + 2H⁺ + 2e⁻ → H₂O (liquid at low T). Net: H₂ + ½O₂ → H₂O. Standard reversible potential E° ≈ 1.229 V at 25 °C, 1 bar.

What to draw and label (no images; describe):

  • Galvanic cell diagram: Left beaker with metal M(s) in M²⁺(aq), right beaker with N(s) in N²⁺(aq). Salt bridge connecting. External wire with voltmeter. Label electron flow from anode to cathode, ion flow in salt bridge (anions to anode, cations to cathode), show half-cells and concentrations.
  • Lead–acid cell: Two plates immersed in H₂SO₄: positive plate grid with PbO₂ active mass (dark), negative plate with spongy Pb (light), separators between plates, show terminals and direction of discharge current.
  • PEM fuel cell: From anode to cathode: gas diffusion layer (GDL), catalyst layer (Pt/C), polymer membrane (e.g., Nafion), catalyst layer, GDL. Arrows: H₂ to anode, O₂/air to cathode, water out at cathode, protons through membrane, electrons through external circuit.

Safety and practical notes (brief): Lithium‑ion requires protection (overcharge, over-discharge, short-circuit, thermal). Lead–acid produces hydrogen on overcharge—ventilation needed. Fuel cells need pure/reactive gases, water/thermal management.

Formulas

ΔG = −n·F·E

  • ΔG: Gibbs free energy change (J·mol⁻¹ of reaction as written), n: electrons transferred per mole of reaction (mol·e⁻ per mol reaction, dimensionless number), F: Faraday constant (96485 C·mol⁻¹), E: cell potential (V). Applies to reversible emf.

E = E° − (R·T)/(n·F) · ln Q

  • E: cell potential (V), E°: standard potential at activities of 1 (V), R: gas constant (8.314 J·mol⁻¹·K⁻¹), T: temperature (K), n: electrons, F: 96485 C·mol⁻¹, Q: reaction quotient (dimensionless) in activities/partial pressures relative to standard state. Applies for equilibrium/OCV.

E ≈ E° − (0.05916/n) · log10 Q (at 298 K) E°_cell = E°_cathode − E°_anode; E_cell = E_cathode − E_anode E° = (R·T)/(n·F) · ln K

  • Same symbols; 0.05916 V comes from 2.303·R·T/F at 298 K. Use for quick calculations at 25 °C.

P = E·I

  • Power P (W), E: terminal voltage (V), I: current (A). Instantaneous power to load.

V_load = E_OCV − I·r

  • V_load: terminal voltage under load (V), E_OCV: open-circuit voltage (V), r: internal resistance (Ω). Linear approximation at small to moderate currents.

Q_cap = I·t

  • Capacity delivered Q_cap (C) for constant current I (A) over time t (s). Convert to A·h by dividing by 3600.

E_energy = V_avg · (Q_Ah) (in W·h)

  • E_energy: delivered energy (W·h), V_avg: average terminal voltage over discharge (V), Q_Ah: discharge capacity (A·h). For Joules, multiply W·h by 3600.

η_fuelcell,max = ΔG/ΔH = E_rev/E_th

  • η_fuelcell,max: maximum thermodynamic efficiency (dimensionless), ΔG (J·mol⁻¹), ΔH (J·mol⁻¹), E_rev = −ΔG/(nF) (V), E_th = −ΔH/(nF) (V). For specified T, p, product phase.

η_voltage ≈ V_actual/E_rev

  • Simple voltage efficiency at given current; V_actual (V), E_rev (V). Does not include fuel utilization or auxiliary loads.

η_act = a + b·log10 i; b = 2.303·R·T/(α·n·F)

  • η_act: activation overpotential (V), a: intercept (V), b: Tafel slope (V·decade⁻¹), i: current density (A·m⁻²), α: charge-transfer coefficient (dimensionless), n: electrons.

iR_drop = i·r_area or I·r

  • Ohmic loss; i: current density (A·m⁻²), A: area (m²), r_area: area-specific resistance (Ω·m²), or lumped current I (A) with r (Ω).

SOC = (Q_remaining/Q_full) · 100%

  • State of charge in percent; Q values in A·h or C consistently.

DoD = 100% − SOC

  • Depth of discharge.

Worked examples

  1. Nernst potential of a PEM H₂–O₂ fuel cell at non-standard pressures Given: Temperature T = 298 K, standard reversible potential E° = 1.229 V for H₂ + ½O₂ → H₂O(l). Partial pressures: p_H2 = 0.50 bar, p_O2 = 0.21 bar. Assume activity of liquid water = 1, standard state 1 bar. Find E.

Steps:

  1. Write reaction quotient using activities/pressures: Q = 1/(a_H2 · a_O2^{1/2}) ≈ 1/[(p_H2/1 bar)·(p_O2/1 bar)^{1/2}].
  2. Use Nernst: E = E° − (R·T)/(n·F) ln Q, with n = 2 for 2 e⁻ per H₂.
  3. Compute factor (R·T)/(n·F) = (8.314·298)/(2·96485) V = 0.01285 V (approx).
  4. Compute ln term: ln(p_H2·p_O2^{1/2}) = ln(0.50·0.21^{1/2}) = ln(0.50·0.4583) = ln(0.2291) = −1.473.
  5. Because Q = 1/(p_H2·p_O2^{1/2}), ln Q = −ln(p_H2·p_O2^{1/2}) = +1.473.
  6. Now E = 1.229 − 0.01285·(1.473) V = 1.229 − 0.0189 V = 1.210 V.

Answer: The reversible cell potential at 298 K is approximately 1.210 V.

  1. Energy delivered and internal heat in a Li‑ion battery discharge Given: A Li‑ion cell with nominal voltage 3.7 V and rated capacity 2.5 A·h is discharged at 0.5C (current I = 1.25 A) for 2.0 h. Average terminal voltage observed V_avg = 3.6 V. Approximate internal resistance r = 0.10 Ω at this current. Find: (a) energy delivered to the load, (b) heat generated internally, both in SI units.

Steps:

  1. Capacity actually delivered at 0.5C for 2 h: Q_Ah = I·t = 1.25 A · 2.0 h = 2.50 A·h (matches rating).
  2. Energy to load (in W·h): E_load,Wh = V_avg · Q_Ah = 3.6 V · 2.50 A·h = 9.0 W·h.
  3. Convert to joules: E_load,J = 9.0 W·h · 3600 s·h⁻¹ = 32400 J.
  4. Internal power loss by ohmic heating: P_loss = I²·r = (1.25 A)² · 0.10 Ω = 0.156 W.
  5. Over 2.0 h (7200 s): E_loss,J = 0.156 W · 7200 s = 1123 J. In W·h: 0.156 W · 2.0 h = 0.312 W·h.
  6. Check consistency: Input chemical energy ≈ electrical to load + heat losses (neglecting other losses). Electrical to load = 32400 J; internal ohmic heat = 1123 J. Total ≈ 33523 J.

Answers: (a) Energy delivered to load ≈ 3.24×10⁴ J. (b) Internal ohmic heat ≈ 1.12×10³ J.

  1. Fuel-cell efficiencies from voltages and heat balance per mole H₂ Given: PEM fuel cell at 298 K, reversible potential E_rev = 1.229 V (to liquid water), thermal voltage E_th = 1.481 V. The cell operates at V_actual = 0.70 V at some current density. Find: (a) thermodynamic maximum efficiency, (b) approximate voltage efficiency at this operating point, (c) electrical work and heat released per mole H₂ consumed (n = 2).

Steps:

  1. (a) η_max = E_rev/E_th = 1.229/1.481 = 0.83 (dimensionless) = 83%.
  2. (b) Voltage efficiency η_voltage ≈ V_actual/E_rev = 0.70/1.229 = 0.569 ≈ 56.9%.
  3. (c) Per mole H₂, charge passed q = n·F = 2 · 96485 C·mol⁻¹ = 192970 C·mol⁻¹.
  4. Electrical work per mole: W_elec = q · V_actual = 192970 C·mol⁻¹ · 0.70 V = 135079 J·mol⁻¹ ≈ 1.35×10⁵ J·mol⁻¹.
  5. Reaction enthalpy to liquid water at 298 K: ΔH° ≈ −285.83 kJ·mol⁻¹. Heat released per mole (assuming steady operation, ignoring auxiliary loads) ≈ |ΔH| − W_elec = 285830 J·mol⁻¹ − 135079 J·mol⁻¹ = 1.51×10⁵ J·mol⁻¹ of heat.

Answers: (a) 83%, (b) 56.9%, (c) Electrical work ≈ 1.35×10⁵ J·mol⁻¹; heat ≈ 1.51×10⁵ J·mol⁻¹.

Common mistakes

  • Writing Nernst equation with Q inverted (forgetting products over reactants in Q) or using concentrations/pressures with units that do not cancel to a dimensionless Q.
  • Using 0.059/n without noting temperature (only valid near 25 °C) or using log₁₀ where ln is required without converting factor 2.303.
  • Ignoring internal resistance; computing energy as E_OCV × Q instead of using average terminal voltage.
  • Confusing primary and secondary reactions (e.g., trying to recharge a primary cell in answers). For lead–acid, forgetting that both plates become PbSO₄ on discharge.
  • In fuel-cell efficiency, dividing by E_rev instead of E_th when asked for thermodynamic maximum (η_max = E_rev/E_th).
  • In Tafel problems, forgetting current density units (A·m⁻²) and mixing with total current.
  • Writing exact dry-cell stoichiometry without indicating it is approximate (depends on electrolyte composition and discharge state).

For your exam

  • Short notes: construction and working of (i) dry cell, (ii) alkaline cell, (iii) lead–acid accumulator, (iv) Li‑ion cell, (v) PEM fuel cell. Include neat labeled diagrams as described, typical nominal voltage, one or two key advantages/limitations.
  • Derivations: (i) ΔG = −nFE, (ii) Nernst equation, (iii) η_max = ΔG/ΔH for fuel cell, (iv) Tafel relation from Butler–Volmer under high overpotential (state assumptions clearly).
  • Numericals: (i) Cell potential using Nernst at given T and concentrations/pressures, (ii) capacity/energy/power calculations at a given C‑rate with internal resistance, (iii) fuel-cell voltage efficiency and heat balance per mole or per second at given current.
  • Comparisons: primary vs secondary batteries; lead–acid vs Li‑ion; fuel cell types (alkaline, PEM, phosphoric acid, molten carbonate, solid oxide) — compare electrolyte, T-range, fuel tolerance, typical applications.
  • Safety/engineering: brief points on thermal management of Li‑ion, hydrogen handling for fuel cells, ventilation for lead–acid.

For full marks: draw clean diagrams with labels; show formulas before substituting numbers; carry SI units through; state assumptions (temperature, standard states, activity approximations); give a concluding sentence with the final numeric answer in appropriate significant figures.

Quick check

  1. State the Nernst equation and define each term.
  2. Write the discharge half-reactions for the lead–acid accumulator at both electrodes.
  3. What is the maximum thermodynamic efficiency of an H₂–O₂ fuel cell at 25 °C making liquid water? Use ΔG° = −237.13 kJ·mol⁻¹ and ΔH° = −285.83 kJ·mol⁻¹.

Answers: 1) E = E° − (R·T)/(n·F) ln Q; E is cell potential, E° standard potential, R gas constant, T temperature, n electrons, F Faraday constant, Q reaction quotient. 2) Anode: Pb + SO₄²⁻ → PbSO₄ + 2e⁻; Cathode: PbO₂ + 4H⁺ + SO₄²⁻ + 2e⁻ → PbSO₄ + 2H₂O. 3) η_max = ΔG/ΔH = 237.13/285.83 = 0.83 (≈83%).

Finished this topic? Mark it so your progress, study plan and readiness keep up.

Stuck on something here?