Fuels: calorific value and analysis of coal
Fuels: calorific value (GCV/NCV), Dulong’s formula, bomb calorimeter principle and corrections, proximate and ultimate analysis of coal with procedures, formulas and worked numericals.
Drafted with Aria, reviewed by the AiCanCode.org team · Updated . How we write and check our notes. Spotted an error? Use Give Feedback at the bottom of the page.
Why it matters
Engineers select fuels and design boilers, furnaces and power plants using the fuel’s heat release per kilogram (calorific value) and its composition. Proximate and ultimate analysis of coal predict combustion behavior, slagging/ash problems, emissions (SO₂, NOₓ), and overall efficiency and cost.
Key ideas
- Calorific value (CV): The heat evolved per unit mass of fuel on complete combustion in oxygen under specified conditions.
- Higher calorific value (HCV or GCV, gross CV): Heat released when water formed from hydrogen in the fuel is fully condensed to liquid water (i.e., includes latent heat of condensation).
- Lower calorific value (LCV or NCV, net CV): Heat released when water remains as vapor (latent heat not recovered). Always NCV ≤ GCV.
- Exact statements used in exams:
- Definition (GCV): “Gross calorific value of a fuel is the total quantity of heat liberated per unit mass of the fuel when it is burnt completely in oxygen and the products of combustion are cooled to the initial temperature of the reactants, so that water formed is condensed to liquid.” Assumption: complete combustion, no heat losses to surroundings other than those accounted, products cooled to reference temperature.
- Definition (NCV): “Net calorific value is the quantity of heat liberated per unit mass of the fuel when burnt completely in oxygen and the products of combustion escape without condensation of the water formed.” Assumption: water leaves as vapor at reference temperature.
- Relation of GCV and NCV: Water produced from hydrogen in the fuel is 9 kg per kg of H. If latent heat of vaporization of water at reference temperature is λ (kJ/kg), then NCV ≈ GCV − 9·H_mass_fraction·λ − moisture_fraction·λ (subtracting also the latent heat to evaporate inherent moisture). Some standards also subtract a small sensible heat term; for first-year exams the latent term is expected.
- Dulong’s formula (empirical estimate of GCV from ultimate analysis): For a coal with mass fractions C, H, O, S (on as‑received basis), an often-used SI version is
- GCV (kJ/kg) ≈ 33800·C + 144000·(H − O/8) + 9300·S, assuming all C→CO₂, H→H₂O, S→SO₂ and that oxygen present in fuel is first used to form water with hydrogen. H − O/8 ensures oxygen in the fuel reduces the effective hydrogen available for combustion heat.
- Assumptions: complete combustion; nitrogen, mineral matter and moisture do not contribute to heat; oxygen in fuel only combines with hydrogen (approximation). It is an estimate; lab calorimetry is preferred.
- Bomb calorimeter (principle and construction):
- Principle: In a strong sealed “bomb” charged with excess O₂ at high pressure, a known mass of powdered fuel burns completely. The heat released raises the temperature of a known mass of water plus the calorimeter body. From the measured temperature rise and known heat capacities, the energy released is found; corrections remove contributions not belonging to the fuel or account for side reactions.
- What to draw and label: Draw a cross-section showing (i) thick-walled steel bomb with screw cap, (ii) oxygen inlet valve, (iii) platinum/nichrome ignition wire touching sample in a small crucible/cup, (iv) sample holder, (v) bomb mounted inside a polished copper/stainless steel calorimeter bucket containing a measured mass of water, (vi) stirrer, (vii) sensitive thermometer/thermistor/probe, (viii) outer water jacket or insulating jacket, (ix) terminals for ignition. Label heat capacities: water mass Mw and calorimeter water equivalent Ccal.
- Corrections: heat from fuse wire and cotton thread (subtract), heat of formation of nitric and sulfuric acids (subtract), cooling correction to account for heat loss during the run (add to effective ΔT). The final value is GCV (gross), because the water formed is condensed inside the bomb.
- Coal analysis:
- Proximate analysis: Determines four groups on as‑received basis: Moisture (M), Volatile Matter (VM), Ash (A), and Fixed Carbon (FC). FC is by difference: FC% = 100 − (M% + VM% + Ash%).
- Moisture: Heat ~105 °C to constant mass in a covered crucible to remove free moisture.
- Volatile matter: Heat the dried sample in a covered crucible at high temperature (about 950 ± 20 °C) for a short fixed time (about 7 minutes) to drive off gases/tars; the loss (excluding moisture) is VM.
- Ash: Burn the residue in an open crucible in a muffle furnace (about 750 °C) to constant mass; residue is ash.
- What to draw and label: Small porcelain/silica crucible with tight-fitting lid; muffle furnace with temperature control; balance for mass readings before/after each step; flow-like diagram: as‑received sample → dry at ~105 °C (Moisture) → cover and heat at ~950 °C (Volatile Matter) → uncover and heat at ~750 °C to constant mass (Ash) → compute Fixed Carbon by difference.
- Significance: M affects handling and NCV; VM indicates ignition ease and tendency to smoke; Ash impacts slagging, fouling and disposal; FC relates to sustained combustion and coke yield.
- Ultimate analysis: Elemental composition: C, H, O, N, S (plus ash, moisture). Classical methods or instruments (CHNS/O analyzers) are used.
- C and H: Complete combustion in oxygen; absorb CO₂ in KOH and H₂O in desiccant (e.g., Mg(ClO₄)₂ or CaCl₂) and weigh increases.
- N: Kjeldahl method (for many coals, not all N forms are captured) or by combustion and thermal conductivity detector (instrumental).
- S: By Eschka mixture method or from bomb washings (precipitate as BaSO₄ and weigh), or by instrument.
- O: Usually by difference: O% ≈ 100 − (C% + H% + N% + S% + Ash% + Moisture%).
- Significance: Predicts GCV (via Dulong), air requirement, flue gas composition, SO₂ emissions, and NCV correction.
- Proximate analysis: Determines four groups on as‑received basis: Moisture (M), Volatile Matter (VM), Ash (A), and Fixed Carbon (FC). FC is by difference: FC% = 100 − (M% + VM% + Ash%).
Formulas
GCV = Qreleased / mfuel, where Qreleased is total heat released (kJ), mfuel is mass of fuel burned (kg); SI: kJ/kg. Applies to bomb calorimeter measurements including corrections described below.
Qreleased = (Mw·cw + Ccal)·ΔT − (Qacid + Qwire + Qcotton) + Qcoolingwhere Mw is mass of water in bucket (kg), cw is specific heat capacity of water (~4.184 kJ·kg⁻¹·K⁻¹), Ccal is calorimeter water equivalent (kJ·K⁻¹), ΔT is observed temperature rise (K), Qacid, Qwire, Qcotton are correction energies (kJ) to subtract, Qcooling is a small correction added (kJ). Applies to bomb calorimeter runs; signs follow the convention that side contributions are subtracted from measured heat.NCV ≈ GCV − 9·H·λ − M·λwhere H is mass fraction of hydrogen in fuel (kg H per kg fuel), M is mass fraction of inherent moisture in fuel, λ is latent heat of vaporization of water at reference temperature (use λ ≈ 2442 kJ·kg⁻¹ at 25 °C unless specified). Applies for first-order NCV correction when water leaves as vapor.GCV (kJ·kg⁻¹) ≈ 33800·C + 144000·(H − O/8) + 9300·Swhere C, H, O, S are mass fractions of carbon, hydrogen, oxygen and sulfur in the fuel (as‑received unless stated). Empirical Dulong estimate; use only if lab value not available.Moisture, M% = (m0 − m1)/m0 × 100where m0 is initial mass (g) and m1 is mass after drying at ~105 °C (g). Applies to proximate moisture.Volatile matter, VM% = (m1 − m2)/m0 × 100where m2 is mass after heating the dried sample in a covered crucible at ~900 °C for the prescribed time. Applies to proximate VM.Ash, A% = (m3)/m0 × 100where m3 is mass of ash after burning the residue in open crucible at ~750 °C to constant mass.Fixed carbon, FC% = 100 − (M% + VM% + A%)by definition in proximate analysis.Air required (theoretical) ≈ (11.6·C + 34.8·H + 4.35·S − 4.35·O) kg air per 100 kg fuel(with C, H, O, S in mass percent, wt%) Optional for context: from stoichiometry using 23% O₂ by mass in air. Use if needed to extend analysis to combustion calculations.
Worked examples
- Bomb calorimeter GCV and NCV Given: Coal sample mass mfuel = 1.10 g = 0.00110 kg. Water in bucket Mw = 1.50 kg. Calorimeter water equivalent Ccal = 0.52 kg water equivalent = 0.52·cw = 0.52·4.184 = 2.176 kJ·K⁻¹. Specific heat of water cw = 4.184 kJ·kg⁻¹·K⁻¹. Temperature rise ΔT = 3.50 K. Corrections: Qwire = 0.12 kJ, Qcotton = 0.05 kJ, Qacid = 0.38 kJ. Assume negligible cooling correction and that the bomb condenses all water formed (GCV measurement). Ultimate analysis shows H = 5.2% and moisture M = 2.0% (mass fractions H = 0.052, M = 0.020) for NCV correction.
Steps:
Compute total heat capacity: (Mw·cw + Ccal) = (1.50·4.184) + 2.176 = 6.276 + 2.176 = 8.452 kJ·K⁻¹.
Heat absorbed by water + calorimeter from temperature rise: (8.452 kJ·K⁻¹)·(3.50 K) = 29.582 kJ.
Subtract corrections not due to fuel: Σcorr = Qwire + Qcotton + Qacid = 0.12 + 0.05 + 0.38 = 0.55 kJ.
Heat due to fuel: Qreleased = 29.582 − 0.55 = 29.032 kJ.
GCV = Qreleased / mfuel = 29.032 kJ / 0.00110 kg = 26,393 kJ·kg⁻¹ = 26.39 MJ·kg⁻¹.
NCV correction: λ = 2442 kJ·kg⁻¹ at 25 °C. Water from hydrogen: 9·H = 9·0.052 = 0.468 kg water/kg fuel; latent heat = 0.468·2442 = 1,142.86 kJ·kg⁻¹. Inherent moisture latent heat: 0.020·2442 = 48.84 kJ·kg⁻¹. NCV ≈ 26,393 − 1,142.86 − 48.84 = 25,201.3 kJ·kg⁻¹ = 25.20 MJ·kg⁻¹.
Dulong’s formula and NCV from ultimate analysis Given ultimate analysis (as‑received): C = 65.0%, H = 5.5%, O = 8.0%, S = 1.2%, N = 1.0%, Ash = 12.3%, Moisture = 7.0%.
Steps:
Convert to mass fractions: C = 0.650, H = 0.055, O = 0.080, S = 0.012.
Dulong GCV: 33800·C = 33800·0.650 = 21,970 kJ·kg⁻¹; 144000·(H − O/8) = 144000·(0.055 − 0.080/8) = 144000·(0.055 − 0.010) = 144000·0.045 = 6,480 kJ·kg⁻¹; 9300·S = 9300·0.012 = 111.6 kJ·kg⁻¹. Sum = 21,970 + 6,480 + 111.6 = 28,561.6 kJ·kg⁻¹ = 28.56 MJ·kg⁻¹.
NCV correction: λ = 2442 kJ·kg⁻¹; water from H = 9·0.055 = 0.495 kg/kg; latent heat = 0.495·2442 = 1,208.79 kJ·kg⁻¹; inherent moisture latent = 0.070·2442 = 170.94 kJ·kg⁻¹. NCV ≈ 28,561.6 − 1,208.79 − 170.94 = 27,181.9 kJ·kg⁻¹ = 27.18 MJ·kg⁻¹.
Proximate analysis: M, VM, Ash, FC Given: As‑received sample mass m0 = 2.500 g.
- After drying at ~105 °C to constant mass: m1 = 2.325 g.
- After heating the dried sample in a covered crucible at ~900 °C for ~7 minutes: mass m2 = 1.425 g.
- After burning the residue in an open crucible at ~750 °C to constant mass: ash mass m3 = 0.300 g.
Steps:
- Moisture, M% = (m0 − m1)/m0 × 100 = (2.500 − 2.325)/2.500 × 100 = 0.175/2.500 × 100 = 7.0%.
- Volatile matter, VM% = (m1 − m2)/m0 × 100 = (2.325 − 1.425)/2.500 × 100 = 0.900/2.500 × 100 = 36.0%.
- Ash, A% = m3/m0 × 100 = 0.300/2.500 × 100 = 12.0%.
- Fixed carbon, FC% = 100 − (M% + VM% + A%) = 100 − (7.0 + 36.0 + 12.0) = 45.0%.
- Interpretation: Medium VM (36%) indicates easy ignition but possible smoke; ash 12% suggests slagging risk; FC 45% supports steady heat release.
Common mistakes
- Forgetting the O/8 term in Dulong’s formula, or using O/16 by mistake. The factor 1/8 arises because 8 kg of oxygen combine with 1 kg of hydrogen to form water.
- Unit errors in bomb calorimetry: using g and kJ inconsistently; keep everything in SI (kg, kJ, K) or be consistent if a non‑SI table is given.
- Wrong sign for bomb corrections: fuse wire, thread, and acid formation add heat not belonging to the coal; subtract them from the measured heat.
- Proximate analysis arithmetic: computing VM as loss from original sample before drying incorrectly; the correct VM% uses (m1 − m2)/m0.
- Reporting ash on dry basis while moisture is as‑received; always state the basis (as‑received, dry basis, dry ash‑free) if asked.
For your exam
- Derivations/relations: Dulong’s formula statement and the reasoning for the O/8 correction; relation NCV = GCV − 9Hλ (plus moisture term if specified). State assumptions clearly.
- Diagrams: Bomb calorimeter (parts and flow of heat); proximate analysis workflow with crucible/muffle furnace stages. Describe exactly what to draw and label.
- Numericals: (i) Bomb calorimeter data to compute GCV/NCV with corrections; (ii) Compute GCV by Dulong from ultimate analysis; (iii) Proximate analysis percentage calculations and FC by difference; (iv) Optional: theoretical air requirement from ultimate analysis.
- Full‑marks answers include: clear definitions with conditions, correct units (kJ/kg), neat, labeled diagram descriptions, all steps with formulas before numbers, conversions of % to fractions, correction terms identified, and a final boxed answer with SI units.
Quick check
- Why is O/8 subtracted in Dulong’s formula term for hydrogen?
- A coal has M = 6%, VM = 32%, Ash = 10%. What is FC%?
- State one key difference between GCV and NCV in one line.
Answers: 1) Because 8 kg of oxygen combine with 1 kg of hydrogen to form water, oxygen already in the fuel reduces the effective hydrogen available for heat release; hence H − O/8. 2) FC% = 100 − (6 + 32 + 10) = 52%. 3) GCV includes the latent heat of condensation of water formed; NCV excludes it (water leaves as vapor).
Finished this topic? Mark it so your progress, study plan and readiness keep up.
Stuck on something here?