Euler's theory of columns
Euler’s theory of columns: elastic buckling of long, slender columns, effective length, end conditions, slenderness ratio, critical load/stress, and limitations.
Drafted with Aria, reviewed by the AiCanCode.org team · Updated . How we write and check our notes. Spotted an error? Use Give Feedback at the bottom of the page.
Why it matters
Columns are everywhere: building frames, machine columns, shafts under compression, piston rods, and masts. Even when the compressive stress is far below yield, a long, slender member can suddenly fail by elastic buckling. Euler’s theory predicts that critical load so you can size members, choose end connections, and avoid catastrophic instability.
Key ideas
- A column/strut is a member primarily under axial compression; a “long” (slender) column tends to fail by buckling (lateral deflection) rather than crushing.
- Buckling is an instability: above a certain axial load, an initially straight column can deflect laterally with no further increase in load. The smallest such load is the Euler critical load.
- Assumptions of Euler’s theory (know these; they frame validity):
- Column is perfectly straight, prismatic, homogeneous, isotropic.
- Load is perfectly axial (no eccentricity) and static.
- Material is linearly elastic with constant E (Young’s modulus); no yielding occurs before buckling.
- Deflections are small; slope dy/dx is small; shear deformation is neglected (pure bending).
- Bending stiffness EI is constant; buckling about the principal axis with least flexural rigidity E·I_min.
- Sign convention and basic relation: Take compression positive P. Let x be along the column, y(x) the lateral deflection; positive y is lateral deflection. The bending moment from axial load acting on the deflected shape is M(x) = −P·y(x). With the elastic curve relation E·I·(d²y/dx²) = M, the governing ODE is: d²y/dx² + (P/(E·I))·y = 0.
- Boundary conditions (end restraints) govern the buckling mode and critical load. Common idealised ends and their effective length factor K:
- Pinned–pinned: K = 1.0 (both ends rotate, no moment; no lateral translation)
- Fixed–fixed: K = 0.5 (both ends built-in)
- Fixed–pinned: K ≈ 0.699 (one end built-in, other hinged)
- Fixed–free (cantilever): K = 2.0 Note: many exam solutions round K ≈ 0.699 to 0.70.
- Effective length: Replace any end condition by an equivalent pin–pin column of length L_e = K·L. Euler’s critical load uses L_e.
- Radius of gyration and slenderness: r = √(I/A); r_min uses I_min. The slenderness ratio is λ = L_e / r_min. Buckling occurs about the axis with the least r (least I). Larger λ means greater susceptibility to buckling.
- Derivation outline (pinned–pinned):
- ODE: d²y/dx² + (P/(E·I))·y = 0 has solution y = C₁ sin(√(P/(E·I)) x) + C₂ cos(√(P/(E·I)) x).
- Apply boundary conditions y(0) = 0 and y(L) = 0 (pins have zero lateral deflection). From y(0)=0 ⇒ C₂ = 0. From y(L)=0 ⇒ sin(√(P/(E·I)) L) = 0 ⇒ √(P/(E·I)) L = n·π, n = 1, 2, …
- The corresponding loads are P_n = n²·π²·E·I / L². The smallest load (n = 1) is the Euler critical load P_cr.
- The buckled shape for n = 1 is y(x) = C sin(π x/L).
- Standard results (via effective length):
- General Euler: P_cr = π²·E·I_min / L_e².
- For the standard end cases, using L_e = K·L:
- Pinned–pinned: P_cr = π²·E·I / L².
- Fixed–fixed: P_cr = 4·π²·E·I / L² (since K = 0.5).
- Fixed–pinned: P_cr ≈ 2.046·π²·E·I / L² (since K ≈ 0.699).
- Fixed–free: P_cr = 0.25·π²·E·I / L² (since K = 2).
- Critical stress expression: σ_cr = P_cr / A = π²·E·r_min² / L_e² = π²·E / λ². This shows why increasing slenderness sharply lowers the elastic buckling stress.
- Limiting/validity:
- Euler theory applies to “long” columns where material remains elastic up to buckling. A practical criterion for the elastic limit slenderness is found by equating σ_cr to the proportional limit σ_p (or to σ_y if data for σ_p is unavailable): λ_c = π·√(E/σ_p) (or π·√(E/σ_y)). For λ > λ_c, Euler is appropriate.
- For intermediate columns (σ_cr near or above σ_p), in practice use empirical/combined formulas (e.g., Rankine–Gordon, Johnson parabolic) — these are part of the broader “Columns and Struts” topic, not Euler’s ideal theory.
- Why real columns differ:
- Initial crookedness, load eccentricity, residual stresses, and imperfect end fixity reduce the true buckling load versus the Euler prediction.
- Buckling usually occurs in the weakest plane (I_min); built-up shapes may need lacing/battening to control local buckling modes.
- Design uses safety factors or code interaction equations instead of taking P_cr directly.
- Mode number: Higher modes (n ≥ 2) have larger critical loads (n² times), so the first mode governs. Do not use higher n for the critical load unless forced by restraints.
Formulas
d²y/dx² + (P/(E·I))·y = 0 — Governing ODE for elastic buckling of a prismatic, perfectly straight, axially compressed column in the elastic range; x, y in m; P in N; E in Pa; I in m⁴.
P_n = n²·π²·E·I / L² — Buckling load for a pin–pin column of length L (m) in mode n = 1, 2, …; E in Pa; I about the buckling axis in m⁴; P_n in N. Use n = 1 for the Euler critical load in the absence of special constraints.
P_cr = π²·E·I_min / L_e² — Euler’s critical load; I_min (m⁴) is the least second moment about principal axes; L_e (m) effective length; E (Pa). Valid for long, elastic columns under axial load.
L_e = K·L — Effective length; L is clear column length (m); K is end-condition factor (dimensionless): pin–pin 1.0, fixed–fixed 0.5, fixed–pinned ≈ 0.699, fixed–free 2.0.
r = √(I/A) — Radius of gyration about an axis; I (m⁴), A (m²), r (m). Use r_min with I_min for buckling.
λ = L_e / r_min — Slenderness ratio (dimensionless); L_e (m), r_min (m).
σ_cr = P_cr / A = π²·E·r_min² / L_e² = π²·E / λ² — Euler critical stress (Pa), A (m²), E (Pa), λ dimensionless. For elastic buckling about the weakest axis.
y(x) = C·sin(n·π·x/L) — Buckled shape for a pin–pin column in mode n; x and L in m; C is amplitude (m).
I_min = A·r_min² — Relation linking area, least radius of gyration, and least second moment; A (m²), r_min (m), I_min (m⁴).
Worked examples
Example 1 — Direct Euler load for a circular pin–pin column Given: Steel column, length L = 2.5 m, circular diameter d = 40 mm, ends pinned. Take E = 200 GPa.
- Data and section properties:
- d = 40 mm = 0.04 m; A = (π/4)·d² = (π/4)·(0.04)² = 0.0012566 m².
- I_min = I = (π/64)·d⁴ = (π/64)·(0.04)⁴ = 1.2566×10⁻⁷ m⁴.
- r = √(I/A) = √(1.2566×10⁻⁷ / 0.0012566) = 0.01 m.
- End conditions: pin–pin ⇒ K = 1.0 ⇒ L_e = K·L = 2.5 m.
- Euler critical load:
- Formula: P_cr = π²·E·I / L_e².
- Numbers: P_cr = (π²)·(200×10⁹ Pa)·(1.2566×10⁻⁷ m⁴) / (2.5 m)².
- Compute numerator: E·I = 200×10⁹ × 1.2566×10⁻⁷ = 2.5132×10⁴ N·m². Multiply by π² ≈ 9.8696 ⇒ 2.4804×10⁵ N·m².
- Denominator: L_e² = (2.5)² = 6.25 m².
- P_cr = 2.4804×10⁵ / 6.25 = 3.9686×10⁴ N.
- Euler critical stress (check elasticity):
- Formula: σ_cr = P_cr / A.
- Numbers: σ_cr = 3.9686×10⁴ N / 0.0012566 m² = 3.156×10⁷ Pa ≈ 31.6 MPa.
- With E = 200 GPa, this is well below common steel yield strengths (~250 MPa), so Euler’s elastic assumption is reasonable.
Answer: Euler critical load P_cr ≈ 39.7 kN; corresponding σ_cr ≈ 31.6 MPa.
Example 2 — GATE-style: end fixity, weak-axis buckling, slenderness Given: A steel column, rectangular cross-section b × h = 60 mm × 30 mm, length L = 3.0 m, one end fixed and the other pinned. Take E = 200 GPa. Find Euler P_cr about the weaker axis, the critical stress, and the slenderness ratio λ. Comment on the strong-axis value.
- Section properties (choose weak axis):
- Convert dimensions: b = 60 mm, h = 30 mm.
- Area: A = b·h = 60×30 = 1800 mm² = 1.8×10⁻³ m².
- Second moments about centroidal axes:
- I_x (about axis through centroid parallel to width, bending with depth h): I_x = (b·h³)/12 = 60×30³/12 = 135,000 mm⁴ = 1.35×10⁻⁷ m⁴.
- I_y (about axis through centroid parallel to depth, bending with width b): I_y = (h·b³)/12 = 30×60³/12 = 540,000 mm⁴ = 5.40×10⁻⁷ m⁴.
- The weaker axis has I_min = I_x = 1.35×10⁻⁷ m⁴. Thus buckling will occur about the plane associated with I_x.
- r_min = √(I_min/A) = √(1.35×10⁻⁷ / 1.8×10⁻³) = √(7.5×10⁻⁵) = 8.660×10⁻³ m.
- Effective length:
- End conditions fixed–pinned ⇒ K ≈ 0.699.
- L_e = K·L = 0.699×3.0 = 2.097 m.
- Euler critical load about weaker axis:
- Formula: P_cr = π²·E·I_min / L_e².
- Numbers: E·I_min = 200×10⁹ × 1.35×10⁻⁷ = 2.70×10⁴ N·m².
- Multiply by π²: 2.70×10⁴ × 9.8696 = 2.6648×10⁵ N·m².
- L_e² = (2.097)² = 4.3974 m².
- P_cr = 2.6648×10⁵ / 4.3974 = 6.060×10⁴ N = 60.6 kN.
- Critical stress and slenderness:
- σ_cr = P_cr / A = 6.060×10⁴ N / 1.8×10⁻³ m² = 3.367×10⁷ Pa = 33.7 MPa.
- λ = L_e / r_min = 2.097 m / 8.660×10⁻³ m = 242.
- Comment on strong-axis buckling:
- I_strong/I_weak = 540,000/135,000 = 4. If everything else same, P_cr,strong ≈ 4×60.6 ≈ 242 kN. Since buckling occurs about the weaker axis first, the governing Euler load is 60.6 kN.
Answer: Euler P_cr(weak axis) ≈ 60.6 kN; σ_cr ≈ 33.7 MPa; λ ≈ 242. Strong-axis P_cr ≈ 242 kN (not governing).
Common mistakes
- Mixing mm and m: using I in mm⁴ with E in Pa or L in m causes errors by factors of 10⁶–10¹². Stick to SI consistently.
- Forgetting to square the effective length (L_e² in the denominator), or using clear length L instead of L_e.
- Using wrong end-fixity factor K (e.g., taking K = 1 for fixed–pinned). Memorise the standard K values.
- Applying Euler to stocky or intermediate columns where σ_cr exceeds the elastic limit; check λ against a transition criterion before using Euler.
- Ignoring eccentricity/initial crookedness when a problem explicitly includes them (that belongs to “Columns and Struts” with the secant formula, not pure Euler). Don’t force Euler where its assumptions are violated.
- Confusing mode shapes and mode numbers; the first mode (n = 1) governs P_cr unless boundary conditions compel otherwise.
For GATE ME
- Quick numericals on P_cr and σ_cr using L_e = K·L. Practise all four standard end conditions and memorize K.
- Determining the governing buckling axis: compute I_x, I_y; choose I_min (or r_min); then use that in Euler.
- Slenderness ratio questions: compute λ = L_e/r_min; infer whether Euler is applicable; note trends (σ_cr ∝ 1/λ²).
- Conceptual comparisons: effect of doubling length (P_cr drops by 4), doubling E or I, changing end restraints, or shifting from pin–pin to fixed–fixed.
- Short derivation/BC recognition: write the differential equation, apply boundary conditions for pin–pin, identify y(x) ∝ sin(πx/L), and extract P_cr.
- Combined ideas: built-up sections (choose I_min), different K values in orthogonal planes (if restraints differ by direction), or comparing P_cr to a given allowable load/safety factor.
- Be ready to spot when Euler is not appropriate (very low λ_c from given σ_y) and to mention Rankine–Gordon/Johnson as alternatives (without derivation here).
Quick check
- A pin–pin steel column’s length is doubled, all else same. By what factor does Euler P_cr change?
- Which axis will a 100 mm × 20 mm rectangular column buckle about first under axial compression?
- What is the effective length factor K for a fixed–free (cantilever) column?
Answers: 1) It becomes one-fourth. 2) About the axis with the smaller second moment (i.e., bending in the thin 20 mm direction; I_min = b·h³/12). 3) K = 2.0.
Finished this topic? Mark it so your progress, study plan and readiness keep up.
Stuck on something here?