Ultrasonics and non-destructive testing
Ultrasonics: generation, properties, detection, and their use in non-destructive testing (NDT) such as pulse‑echo, through‑transmission, and A/B/C‑scan methods.
Drafted with Aria, reviewed by the AiCanCode.org team · Updated . How we write and check our notes. Spotted an error? Use Give Feedback at the bottom of the page.
Why it matters
Ultrasonic waves let engineers “look inside” a material without cutting it, to find cracks, voids, corrosion, and thickness loss. Non‑destructive testing (NDT) using ultrasonics is routine in aerospace, automotive, rail, pipelines, power plants, civil structures, and manufacturing quality control.
Key ideas
- Wave speed: In a medium, wave speed depends on its elastic properties and density.
- Exact statements commonly used:
- In a fluid (no shear), the longitudinal speed is
v = sqrt(K / ρ), whereKis bulk modulus andρis density. - In a solid, the longitudinal speed is
v_L = sqrt((E(1 − ν)) / (ρ(1 + ν)(1 − 2ν)))in terms of Young’s modulusEand Poisson’s ratioν. A commonly used approximation along a thin rod isv_L ≈ sqrt(E / ρ)(assumes one‑dimensional rod, low frequency, negligible lateral strain). - Shear wave speed in a solid is
v_S = sqrt(G / ρ), whereGis shear modulus.
- In a fluid (no shear), the longitudinal speed is
- Exact statements commonly used:
- Wavelength and frequency:
λ = v / f. Higher frequency gives smaller wavelength and better resolution, but more attenuation. - Acoustic impedance:
Z = ρ v. It controls how much sound is reflected or transmitted at an interface. - Reflection and transmission at normal incidence:
- Pressure (or particle velocity) boundary conditions lead to intensity reflection coefficient
R = ((Z2 − Z1) / (Z2 + Z1))^2and intensity transmission coefficientT = 1 − Rat a plane interface between media of impedancesZ1andZ2.
- Pressure (or particle velocity) boundary conditions lead to intensity reflection coefficient
- Attenuation: Field amplitude decays with distance as
A(x) = A0 e^(−α x)whereαis the amplitude attenuation coefficient (Np·m⁻¹); consequently intensity decays asI(x) = I0 e^(−2α x). Attenuation increases with frequency in many materials; 1 Np = 8.686 dB for field amplitude. - Near field and beam spread (for a circular piston transducer in a fluid):
- Near field length:
N ≈ D^2 / (4 λ)(D = diameter). Beyond this, in the far field, the main lobe spreads. - Beam divergence (half‑angle to first null) approximately satisfies
sin θ ≈ 1.22 λ / D(small‑angle:θ ≈ 1.22 λ / D).
- Near field length:
- Pulse‑echo principle: A short ultrasonic pulse enters the material; echoes come back from interfaces like the front wall, flaws, and back wall. Time‑of‑flight gives distances. For normal incidence, thickness
t = v Δt / 2(factor 1/2 because the pulse travels down and back). - Through‑transmission: A transmitter on one side and a receiver on the other side. A flaw reduces received amplitude or blocks the signal.
- A‑scan, B‑scan, C‑scan:
- A‑scan: Amplitude vs time. Vertical spikes indicate echoes and their times (depths).
- B‑scan: A line of A‑scans composed as a cross‑sectional profile (depth vs lateral position, grayscale by amplitude/time).
- C‑scan: Plan‑view map (top‑down) at a chosen depth/time gate; intensity/colour represents echo amplitude.
- Transducer types:
- Piezoelectric transducer: Uses the piezoelectric effect (mechanical strain produces voltage; applied voltage produces strain). A piezoelectric crystal plate (e.g., PZT) is bonded to a backing and a wear plate; an RF burst excites it near its thickness resonance
f ≈ v_crystal / (2 t_crystal). - Magnetostrictive transducer: A ferromagnetic rod changes length with magnetization. A coil with AC drive and a bias magnet/field produce ultrasonic vibrations (typically lower frequency, robust for high‑power ultrasonics).
- Piezoelectric transducer: Uses the piezoelectric effect (mechanical strain produces voltage; applied voltage produces strain). A piezoelectric crystal plate (e.g., PZT) is bonded to a backing and a wear plate; an RF burst excites it near its thickness resonance
- Couplant and surface preparation: Air gaps reflect almost all ultrasound (very high impedance mismatch). A couplant (gel/oil/water) fills microgaps to transmit energy.
- Calibration: Use reference blocks with known geometry and Artificial Reflectors (e.g., side‑drilled holes, notches) to set gain, time‑base (velocity), and check resolution/sensitivity.
- Resolution vs penetration trade‑off: Higher frequency improves axial (depth) and lateral resolution but increases attenuation; choose frequency based on material and required flaw size.
- Sizing and locating flaws:
- Depth from time‑of‑flight:
depth = (v × time_to_echo)/2(pulse‑echo). - Amplitude and time gating estimate flaw size and reflectivity; DAC/TCG curves compensate for depth‑dependent attenuation and beam spread.
- Angle‑beam (shear‑wave) inspection uses wedges to introduce refracted angles (Snell’s law) to find cracks not normal to the surface (e.g., weld toe cracks).
- Depth from time‑of‑flight:
What to draw in exam answers (describe and label):
- Pulse‑echo block diagram: Function generator (pulser) → damping network → piezoelectric probe (transmitter/receiver) on test specimen with couplant → echoes return → receiver amplifier → time‑base/oscilloscope (A‑scan display) with labeled front‑surface echo, flaw echo, back‑wall echo; annotate
Δtand depth relationt = v Δt / 2. - Piezoelectric transducer cross‑section: Wear plate, piezoelectric element with electrodes, backing (damping), housing, cable; show emitted ultrasonic beam into specimen; indicate near field N and far field qualitatively.
- A‑scan, B‑scan, C‑scan schematics: For A‑scan, vertical axis amplitude, horizontal axis time; spikes for echoes. For B‑scan, a slice showing curved/straight indications vs depth. For C‑scan, a top‑view intensity map with a gated depth.
- Magnetostrictive setup: Ferromagnetic rod with coil, bias magnet, horn or waveguide tip, specimen contact.
- Normal‑incidence reflection at interface: Two media with
Z1,Z2; incident, reflected, transmitted rays normal to interface; annotateRandT.
Assumptions that are often implicit in exam derivations:
- Plane wave, normal incidence, linear elastic, isotropic, homogeneous media unless otherwise stated.
- Perfect coupling (no air gap) when using formulas for reflection/transmission at a solid–solid or solid–liquid interface.
- For
t = v Δt / 2, the echo arises from a planar parallel back wall and the wave path is straight without mode conversion.
Formulas
f > 20 kHz — Definition of ultrasonic frequency; f: frequency (Hz).
λ = v / f — Wavelength–frequency relation; λ: wavelength (m), v: wave speed (m·s⁻¹), f: frequency (Hz); applies to any harmonic wave in a medium.
v = sqrt(K / ρ) — Longitudinal wave speed in a fluid; K: bulk modulus (Pa), ρ: density (kg·m⁻³).
v_L = sqrt((E(1 − ν)) / (ρ(1 + ν)(1 − 2ν))) — Longitudinal speed in an isotropic solid; E: Young’s modulus (Pa), ν: Poisson’s ratio (dimensionless), ρ: density (kg·m⁻³).
v_L ≈ sqrt(E / ρ) — Approximate longitudinal speed for a slender rod at low frequency; E: Pa, ρ: kg·m⁻³.
v_S = sqrt(G / ρ) — Shear wave speed in a solid; G: shear modulus (Pa), ρ: kg·m⁻³.
Z = ρ v — Acoustic impedance; Z: Pa·s·m⁻¹ (Rayl), ρ: kg·m⁻³, v: m·s⁻¹.
R = ((Z2 − Z1) / (Z2 + Z1))^2 — Intensity reflection coefficient at normal incidence; Z1, Z2: Rayl; applies for plane wave, lossless boundary.
T = 1 − R — Intensity transmission coefficient at normal incidence; same assumptions as above.
I(x) = I0 e^(−2α x) — Attenuation of intensity when field amplitude decays as A(x) = A0 e^(−α x); I0: initial intensity (W·m⁻²), I(x): at distance x (m), α: amplitude attenuation coefficient (Np·m⁻¹).
N ≈ D^2 / (4 λ) — Near field length of a circular piston transducer; N: m, D: diameter (m), λ: m; fluid medium approximation.
sin θ ≈ 1.22 λ / D — Far‑field main‑lobe half‑angle for a circular piston; θ: rad (for small angles); λ: m; D: m.
t = v Δt / 2 — Thickness or depth from pulse‑echo time‑of‑flight; t: m, v: m·s⁻¹, Δt: round‑trip time (s); assumes normal incidence, straight path, same medium both ways.
f_res ≈ v_piezo / (2 t_piezo) — Thickness resonance of a piezoelectric plate; v_piezo: longitudinal speed in crystal (m·s⁻¹), t_piezo: thickness (m).
Snell’s law: sin i / v1 = sin r / v2 — Refraction of ultrasound at an interface; i: incident angle, r: refracted angle, v1, v2: speeds in respective media; applies separately for longitudinal and shear modes.
Worked examples
- Pulse‑echo thickness measurement of a steel plate Given: A normal‑incidence probe on a steel plate shows a back‑wall echo at Δt = 1.70 µs after the front‑surface pulse. Take longitudinal speed in steel v = 5900 m·s⁻¹.
Steps:
- Write the relation: t = v Δt / 2.
- Substitute numbers with units: t = (5900 m·s⁻¹ × 1.70 × 10⁻⁶ s)/2.
- Compute: 5900 × 1.70 × 10⁻⁶ = 0.01003 m; divide by 2 → 0.005015 m.
- Convert to mm: 0.005015 m = 5.015 mm.
Final answer: The plate thickness is approximately 5.02 mm (rounded to three significant figures). — Bold: 5.02 mm.
- Reflection at a water–steel interface (normal incidence) Given: Densities and wave speeds (approximate): water ρ1 = 1000 kg·m⁻³, v1 = 1480 m·s⁻¹; steel ρ2 = 7850 kg·m⁻³, v2 = 5900 m·s⁻¹. Find intensity reflection coefficient R for a wave in water incident on steel.
Steps:
- Compute impedances: Z1 = ρ1 v1 = 1000 × 1480 = 1.48 × 10⁶ Rayl; Z2 = ρ2 v2 = 7850 × 5900 = 4.6315 × 10⁷ Rayl.
- Use
R = ((Z2 − Z1)/(Z2 + Z1))^2. - Numerator: Z2 − Z1 = 4.6315 × 10⁷ − 1.48 × 10⁶ = 4.4835 × 10⁷ Rayl.
- Denominator: Z2 + Z1 = 4.6315 × 10⁷ + 1.48 × 10⁶ = 4.7795 × 10⁷ Rayl.
- Ratio: (4.4835/4.7795) = 0.9381 (dimensionless).
- Square: R = 0.9381² ≈ 0.8800.
Final answer: About 88.0% of incident intensity is reflected at water–steel (normal incidence). — Bold: 0.880 (≈ 88.0%).
- Required probe frequency for a target wavelength in water Aim: Choose frequency so that wavelength is λ = 1.0 mm in water (v ≈ 1480 m·s⁻¹).
Steps:
- Use
λ = v / f→f = v / λ. - Substitute: f = 1480 m·s⁻¹ / (1.0 × 10⁻³ m) = 1.48 × 10⁶ s⁻¹.
Final answer: Use a probe frequency of about 1.48 MHz. — Bold: 1.48 MHz.
- Flaw depth from A‑scan time‑of‑flight in an aluminium block Given: In aluminium (take v = 6320 m·s⁻¹ longitudinal), a flaw echo appears at Δt = 12.0 µs after the front‑surface signal. Find flaw depth from the entry surface.
Steps:
- Use
depth = v Δt / 2. - Compute: depth = (6320 m·s⁻¹ × 12.0 × 10⁻⁶ s)/2 = (0.07584 m)/2 = 0.03792 m.
- Convert: 0.03792 m = 37.92 mm.
Final answer: The flaw is at a depth of approximately 37.9 mm. — Bold: 37.9 mm.
Common mistakes
- Confusing amplitude reflection coefficient with intensity reflection coefficient; exam questions usually expect
Rfor intensities:R = ((Z2 − Z1)/(Z2 + Z1))^2. - Ignoring coupling: assuming significant transmission across an air gap; in reality, air–solid mismatch makes R ≈ 1 (almost total reflection).
- Not accounting for attenuation and beam spread when comparing echo amplitudes from different depths; deeper echoes are naturally weaker.
- Misreading A‑scan time origin: measuring from the front‑surface echo rather than from the initial pulse (or vice versa) without clarity; always state your reference.
- Drawing unlabeled diagrams: missing axes (amplitude vs time), missing Z1, Z2 on interface diagrams, or not marking Δt and depth relation.
- Overlooking near field: placing the region of interest within the highly variable near field can give unstable amplitudes; exams may ask for near‑field estimate.
For your exam
- Derivations: Wave speed in fluids
v = sqrt(K/ρ); relationλ = v/f; reflection coefficientRat normal incidence using boundary conditions; near field lengthN ≈ D^2/(4λ)(outline level); resonance of a piezo platef_res ≈ v/(2t). - Numericals: Thickness by pulse‑echo; depth of flaw from time‑of‑flight; reflection and transmission coefficients at interfaces; selecting frequency for desired wavelength/resolution; estimating beam divergence
θor near fieldNfor a given probe. - Diagrams: Pulse‑echo setup and A‑scan display with labeled echoes; piezoelectric probe cross‑section; through‑transmission setup; normal‑incidence reflection diagram; A/B/C‑scan schematics.
- Full‑marks answers usually include: clear definitions with units, correct formulas with stated assumptions, neat labeled diagrams as described, step‑by‑step calculations with units, a statement on limitations/assumptions (e.g., normal incidence, plane wave), and a short concluding remark on interpretation (e.g., why an echo is weaker/deeper).
Quick check
- Define acoustic impedance and write its SI unit.
- A 5 MHz probe inspects acrylic (v = 2730 m·s⁻¹). What is the wavelength in the acrylic?
- Why is a couplant necessary between a probe and a metallic specimen?
Answers: (1) Z = ρ v; unit Rayl (Pa·s·m⁻¹). (2) λ = v/f = 2730/5.0×10⁶ = 5.46×10⁻⁴ m = 0.546 mm. (3) To eliminate air gaps and reduce the huge impedance mismatch with air; couplant enables efficient transmission of ultrasonic energy into the metal.