Magnetic materials
Magnetic materials: definitions (B, H, M, χ, μr), types (dia-/para-/ferro-/ferri-/antiferromagnetic), domain theory, Curie and Curie–Weiss laws, hysteresis and energy loss, soft vs hard magnets, measurement (Gouy/Quincke), key formulas and examples.
Drafted with Aria, reviewed by the AiCanCode.org team · Updated . How we write and check our notes. Spotted an error? Use Give Feedback at the bottom of the page.
Why it matters
Magnetic materials are everywhere in engineering: transformer cores, motors and generators, inductors, magnetic sensors, recording heads, MRI magnets, and magnetic shielding. Choosing the right material (soft vs hard, metallic vs ferrite) affects efficiency, size, heating, and reliability of electrical and electronic systems.
Key ideas
- Magnetic flux density (B): A vector field that represents the density of magnetic flux lines (also called magnetic induction). SI unit: tesla (T). In materials,
B = μ0 (H + M). - Magnetization (M): Magnetic dipole moment per unit volume induced or present in a material. SI unit: A/m. For linear, isotropic materials at low fields,
M = χ·H. - Magnetic susceptibility (χ): A dimensionless proportionality constant defined by
M = χ·H(volume susceptibility). It measures how easily a material magnetizes. - Permeability (μ) and relative permeability (μr):
μ = B/Honly in linear, isotropic media; more generallyB = μ0 (H + M). Relative permeabilityμr = μ/μ0 = 1 + χfor linear, isotropic materials. SI unit of μ: henry per metre (H/m). μr is dimensionless.
Types of magnetic materials (by χ and domain behavior)
- Diamagnetic materials: χ is small and negative (typically about −10⁻⁶ to −10⁻⁵). Induced magnetization opposes the applied field. Examples: bismuth, copper, water.
- Paramagnetic materials: χ is small and positive (typically about 10⁻⁶ to 10⁻³). Induced magnetization aligns with the field and disappears when field is removed. Examples: aluminium, platinum, some ionic salts.
- Ferromagnetic materials: Very large apparent μr, nonlinear and hysteretic behavior, strong magnetization persists (domains align). Examples: Fe, Co, Ni and many of their alloys.
- Antiferromagnetic materials: Equal but oppositely aligned magnetic sublattices; net magnetization ≈ 0 at low field. Above Néel temperature they become paramagnetic. Example: MnO.
- Ferrimagnetic materials: Oppositely aligned sublattices with unequal moments → nonzero net magnetization; typically ceramic oxides (ferrites) with high resistivity and useful at high frequencies.
Microscopic picture and temperature laws
- Langevin (classical) diamagnetism (idea only): Electron orbits adjust to oppose change in magnetic flux (Lenz-like response), giving a temperature-independent small negative χ.
- Langevin (paramagnetism) and Curie law: For N non-interacting magnetic dipoles of moment μ in a magnetic field of flux density B at absolute temperature T, the magnetization is M = N μ L(α), where L is the Langevin function and α = μ B / (kB T) (≈ μ μ0 H / (kB T) in free space). For small α (weak field, high T),
L(α) ≈ α/3, soM ≈ (N μ^2 μ0 / (3 kB T)) H. Hence the Curie law: “In a paramagnetic material, magnetic susceptibility varies inversely with absolute temperature:χ = C / T, whereC = μ0 N μ^2 / (3 kB)is the Curie constant.” Assumptions: non-interacting magnetic moments, classical orientation distribution, weak field or high temperature (α ≪ 1). - Weiss molecular field and Curie–Weiss law (ferromagnets above Tc): Weiss postulated an internal molecular field proportional to magnetization:
Hint = λ M. For T > Tc, susceptibility follows the Curie–Weiss law: “χ = C / (T − Tc).” Assumptions: mean-field approximation; valid above the Curie temperature. For antiferromagnets above the Néel temperature TN,χ ≈ C / (T + θ)withθ > 0.
Domains and hysteresis
Magnetic domains: Regions within a ferromagnet where spins are parallel and magnetization is uniform. In zero applied field, domains are arranged to minimize net magnetization and stray field energy.
Domain walls (Bloch walls): Thin transition regions separating domains with different magnetization directions. Movement and pinning of walls underlie hysteresis and coercivity.
Hysteresis loop: Plot of B versus H for a ferromagnet cycled through a complete magnetization cycle. Key points:
- Saturation: Beyond a sufficiently high H, magnetization reaches a maximum; B increases little with more H.
- Retentivity (remanence, Br): The value of B remaining when H is reduced to zero from positive saturation.
- Coercivity (Hc): The negative H required to bring B back to zero after saturation.
- Hysteresis loss: The energy loss per unit volume per cycle equals the area of the B–H loop (in SI units of J/m³ per cycle).
What to draw for hysteresis (exam diagram): Draw axes with horizontal H (A/m) and vertical B (T). Sketch a typical loop showing: origin, saturation plateau in first quadrant, the remanence Br on the B axis when H = 0, the coercive field −Hc on the H axis when B = 0, and the symmetric parts in other quadrants. Label Br, Hc, and indicate “area = hysteresis loss per unit volume per cycle.” Also mark B = μ0(H + M) near the linear initial magnetization curve.
Soft vs hard magnetic materials (engineering classification)
- Soft magnetic materials: Easily magnetized and demagnetized; low coercivity, narrow hysteresis loop, small hysteresis loss; high initial permeability. Examples: soft iron, silicon steel (electrical steel), permalloy, ferrites (Mn–Zn, Ni–Zn). Applications: transformer cores, motor stators/rotors, inductors, electromagnetic relays.
- Hard (permanent) magnetic materials: Difficult to magnetize/demagnetize; high coercivity, large remanence; wide loop. Examples: steel, AlNiCo, SmCo, Nd–Fe–B. Applications: permanent magnets in motors, loudspeakers, magnetic clamps.
Demagnetizing field and sample shape (concept)
- Finite specimens develop a demagnetizing field opposing magnetization, depending on shape. For ellipsoids, internal field
Hint = Happ − N M, where N is the demagnetizing factor (dimensionless, 0–1 depending on axis). This affects measured μ and χ. Assumes uniform M (ellipsoidal geometry).
Measuring susceptibility (brief)
- Gouy balance method (solids): A long, slender sample is partially inserted into a non-uniform magnetic field. The magnetic force changes the apparent weight. For a uniform cross-sectional area A and field B at the end face, the upward force is approximately
F = (χ A / (2 μ0)) (B_in² − B_out²). If the external field is negligible,F ≈ (χ A B²) / (2 μ0). From the measured mass change Δm:χ = (2 μ0 Δm g) / (A B²)(sign shows dia-/para-). Assumptions: long sample, uniform B at the end, small χ. - Quincke’s method (liquids): A paramagnetic or diamagnetic liquid in a U-tube with a bulb between pole pieces rises or falls by height h in a magnetic field due to pressure difference. For a liquid of density ρ,
χ = (2 μ0 ρ g h) / (B²)(sign from direction). Assumes small χ and uniform B in bulb.
Magnetic energy (useful relation)
- Energy density stored in a magnetic field in a material:
u = ∫₀^B H dB. For linear isotropic materials,u = (B·H)/2 = (B²)/(2 μ) = (μ H²)/2.
Microscopic magnetic moments
- Bohr magneton (μB): Fundamental unit of magnetic moment for an electron:
μB = e ħ / (2 me) ≈ 9.274 × 10⁻²⁴ A·m². Effective moments of ions often expressed asμeff = g √{J(J+1)} μB(quantum; beyond our scope here), used in Curie constant.
Applications summary
- Minimize core losses (hysteresis + eddy current) in transformers: choose high-resistivity, low-coercivity laminations or ferrites; operate below saturation; proper lamination thickness/insulation.
- Permanent magnets: pick high Br and high Hc (large energy product (BH)max) for compact motors and actuators.
- Sensors and shielding: use high-μ soft materials to guide flux and reduce stray fields.
Formulas
B = μ0 (H + M) — B: magnetic flux density (T), H: magnetic field intensity (A/m), M: magnetization (A/m), μ0: permeability of free space (H/m). General relation in materials.
M = χ·H — M: magnetization (A/m), H: field (A/m), χ: volume magnetic susceptibility (dimensionless). Linear, isotropic, weak-field approximation.
μ = μ0 μr — μ: permeability (H/m), μ0: 4π×10⁻⁷ H/m, μr: relative permeability (dimensionless). Definition.
μr = 1 + χ — μr: relative permeability (dimensionless), χ: susceptibility (dimensionless). Linear, isotropic materials.
χ = C / T — χ: paramagnetic susceptibility (dimensionless), C: Curie constant (K), T: absolute temperature (K). Curie law, weak fields.
C = μ0 N μ² / (3 kB) — C: Curie constant (K), μ0: H/m, N: number density (m⁻³), μ: magnetic moment (A·m²), kB: Boltzmann constant (J/K). Paramagnets of non-interacting moments.
χ = C / (T − Tc) — χ: susceptibility (dimensionless), C: Curie constant (K), T: temperature (K), Tc: Curie temperature (K). Curie–Weiss law for T > Tc.
u = ∫₀^B H dB — u: magnetic energy density (J/m³), H: field (A/m), B: flux density (T). General energy relation.
u = (B·H)/2 = B²/(2 μ) = μ H²/2 — u: J/m³, B: T, H: A/m, μ: H/m. For linear, isotropic media.
W_cycle = ∮ H dB — W_cycle: hysteresis energy loss per unit volume per cycle (J/m³), loop integral over one B–H cycle. SI axes (B in T, H in A/m).
F = (χ A B²) / (2 μ0) — F: magnetic force on long sample end face (N), χ: susceptibility (dimensionless), A: cross-sectional area (m²), B: flux density at end face (T), μ0: H/m. Gouy method approximation.
χ = (2 μ0 Δm g) / (A B²) — χ: susceptibility (dimensionless), Δm: apparent mass change (kg), g: 9.81 m/s², A: m², B: T, μ0: H/m. From Gouy force balance (sign by observed direction).
χ = (2 μ0 ρ g h) / (B²) — χ: susceptibility (dimensionless), ρ: liquid density (kg/m³), g: m/s², h: rise/fall (m), B: T, μ0: H/m. Quincke’s method (sign by rise/fall).
Hint = Happ − N M — Hint: internal field (A/m), Happ: applied external field (A/m), N: demagnetizing factor (dimensionless), M: A/m. Uniformly magnetized ellipsoid approximation.
μB = 9.274 × 10⁻²⁴ A·m² — Bohr magneton magnitude; constant used in Curie constant with μ expressed in A·m².
Worked examples
Example 1: Compute B and M for a paramagnetic material Given: χ = 0.002 (dimensionless), H = 1.0 × 10⁴ A/m, μ0 = 4π × 10⁻⁷ H/m.
Use M = χ·H. M = 0.002 × (1.0 × 10⁴ A/m) = 20 A/m.
Use B = μ0 (H + M) = μ0 H (1 + χ). μ0 H = (4π × 10⁻⁷ H/m) × (1.0 × 10⁴ A/m) = 4π × 10⁻³ T ≈ 0.0125664 T. 1 + χ = 1.002. B = 0.0125664 T × 1.002 ≈ 0.0125915 T.
Answer: M = 20 A/m, B ≈ 0.01259 T.
Example 2: Curie law susceptibility and magnetization A paramagnetic salt has number density N = 8.5 × 10²⁷ m⁻³ and effective moment μeff = 5 μB (μB = 9.274 × 10⁻²⁴ A·m²). Find χ at T = 300 K and M when H = 5.0 × 10³ A/m. Constants: μ0 = 4π × 10⁻⁷ H/m, kB = 1.380649 × 10⁻²³ J/K.
Compute Curie constant C = μ0 N μeff² / (3 kB). μeff² = (5 × 9.274 × 10⁻²⁴ A·m²)² = 25 × (9.274 × 10⁻²⁴)² A²·m⁴. (9.274 × 10⁻²⁴)² ≈ 8.600 × 10⁻⁴⁷ → μeff² ≈ 2.150 × 10⁻⁴⁵ A²·m⁴. Numerator μ0 N μeff² ≈ (1.256637 × 10⁻⁶) × (8.5 × 10²⁷) × (2.150 × 10⁻⁴⁵) = 1.256637 × 8.5 × 2.150 × 10^(−6+27−45) = 22.98 × 10⁻²⁴ ≈ 2.298 × 10⁻²³ (A²·m⁴·H/m units consistent). Denominator 3 kB = 3 × 1.380649 × 10⁻²³ = 4.141947 × 10⁻²³ J/K. C = (2.298 × 10⁻²³) / (4.141947 × 10⁻²³) ≈ 0.5547 (K).
Note: Carefully tracking exponents gives C ≈ 0.555 K; a power-of-ten slip would incorrectly give 5.55 K. We proceed with 0.555 K (checked with a calculator).
Curie law χ = C / T = 0.555 / 300 ≈ 0.00185 (dimensionless).
Magnetization M = χ·H = 0.00185 × (5.0 × 10³ A/m) = 9.25 A/m.
Answer: χ ≈ 1.85 × 10⁻³, M ≈ 9.25 A/m.
Example 3: Hysteresis loss from a plotted B–H loop A B–H hysteresis loop of a core material is plotted with scales: 1 cm = 0.20 T on the B-axis and 1 cm = 1000 A/m on the H-axis. The measured area enclosed by the loop on the graph is 18 cm². The core volume is 2.0 × 10⁻³ m³ and it is cycled at 50 Hz. Compute the hysteresis power loss.
Energy loss per unit volume per cycle equals the geometrical area × scale factors: W_cycle (J/m³) = (area on paper) × (B scale in T/cm) × (H scale in A/m per cm). W_cycle = 18 cm² × (0.20 T/cm) × (1000 A/m per cm) = 18 × 200 = 3600 J/m³.
Power loss P = W_cycle × frequency × volume. P = (3600 J/m³) × (50 s⁻¹) × (2.0 × 10⁻³ m³) = 3600 × 50 × 0.002 W = 360 W.
Answer: Hysteresis power loss ≈ 360 W.
Common mistakes
- Forgetting SI units: reporting Br in A/m (should be tesla) or Hc in tesla (should be A/m).
- Using χ = μr instead of μr = 1 + χ.
- Applying Curie law χ = C/T to ferromagnets below Tc (not valid), or to strong fields where L(α) is not small.
- Confusing remanence Br with coercivity Hc on the hysteresis loop axes.
- Calculating hysteresis loss using the M–H loop area while the plotted graph is B–H (or mixing up ∮H dB vs ∮B dH). In SI with B–H axes, the area is W_cycle = ∮ H dB.
- Ignoring demagnetizing field: reporting an intrinsic μr from a measurement on a short cylinder without accounting for shape effects.
- Numerical slips in Curie constant: losing track of powers of ten and the square of μeff; not converting μeff to A·m² properly.
For your exam
- Short notes: Soft vs hard magnetic materials with applications; ferrites and why used at high frequency; demagnetizing field and shape factor; magnetic recording materials; magnetostriction (if in your syllabus).
- Derivations: Curie law from Langevin theory (show M = N μ L(α), expand L(α) ≈ α/3 → χ = C/T); Curie–Weiss law idea (Weiss field, susceptibility above Tc); expression for hysteresis loss as area of B–H loop; magnetic energy density u for linear media.
- Diagrams: Neat B–H hysteresis loop labeled with Br and Hc; schematic magnetic domains and Bloch wall; energy loss indicated by loop area. State scales if a measurement question is asked.
- Numericals: Compute B and M from given H and χ; compute χ at a temperature using Curie law and given N, μeff; find hysteresis loss from a plotted loop (use scales and area); simple demagnetizing field correction using Hint = Happ − N M for given N.
- Full-marks answers: Define terms clearly with units, state assumptions (e.g., non-interacting moments), write formulas before substituting numbers, carry SI units through every step, and present a final boxed answer with correct significant figures.
Quick check
- State the relation between B, H, and M in SI units.
- Name the law that gives χ ∝ 1/T for paramagnets and write its formula.
- What graph area gives hysteresis energy loss per unit volume per cycle when axes are B (T) and H (A/m)?
Answers: 1) B = μ0 (H + M). 2) Curie law: χ = C/T. 3) The area of the B–H loop, equal to ∮ H dB (J/m³ per cycle).
Finished this topic? Mark it so your progress, study plan and readiness keep up.
Stuck on something here?