Three-phase induction motor: basics

Three-phase induction motor basics: construction, rotating magnetic field, synchronous speed, slip, rotor frequency, power flow, equivalent circuit, torque–slip characteristic, starting methods, and key formulas with examples.

Drafted with Aria, reviewed by the AiCanCode.org team · Updated . How we write and check our notes. Spotted an error? Use Give Feedback at the bottom of the page.

Why it matters

Three-phase induction motors are the workhorse of industry: pumps, fans, compressors, conveyors, machine tools, and HVAC all use them. As a first-year engineer, you must know how they work, how to compute speed, slip, torque and power, and how to select and start them safely.

Key ideas

  • The stator is the stationary part with three-phase windings placed in slots of a laminated steel core. When connected to a balanced three-phase supply, it creates a rotating magnetic field (RMF).

  • The rotor is the rotating part. Two common types:

    • Squirrel-cage rotor: rotor bars (usually aluminium or copper) short-circuited by end rings; robust and simple.
    • Slip-ring (wound) rotor: three-phase rotor winding connected to external resistors via slip rings; used for high starting torque and speed control.
  • The air gap is the small uniform space between stator and rotor; its size affects magnetising current and torque capability.

  • The frame, bearings, fan, and terminal box support, cool, and connect the motor.

  • Rotating magnetic field (RMF)

    • Definition: A rotating magnetic field is a magnetic field of constant magnitude that rotates at a constant speed inside the air gap owing to balanced three-phase currents displaced by 120°.
    • Exact statement (for exam): In a three-phase, symmetrically distributed stator winding fed by a balanced three-phase sinusoidal voltage of frequency f, the resultant air-gap flux density is of constant amplitude and rotates at the synchronous speed N_s = 120·f/P rpm, where P is the number of poles.
    • What to draw: Sketch a 2-pole, three-phase stator with phase axis a–a′, b–b′, c–c′ spaced 120° electrical, and plot three sine waves of currents i_a, i_b, i_c phase-shifted by 120°. Show the resultant rotating flux vector of constant length rotating anticlockwise.
  • Synchronous speed and slip

    • Definition: Synchronous speed (N_s) is the speed of the rotating magnetic field: N_s = 120·f/P rpm, where f is supply frequency in hertz, P is number of poles.
    • Definition: Slip (s) is the fractional difference between synchronous speed and rotor mechanical speed N: s = (N_s − N)/N_s (dimensionless). It is always between 0 and 1 in motoring mode.
    • Definition: Rotor electrical frequency (f_2) is the frequency of induced rotor currents: f_2 = s·f_1, where f_1 is supply frequency.
  • Principle of operation (induction)

    • The changing RMF cuts stationary rotor conductors, inducing an EMF (Faraday’s law). This EMF drives rotor currents (the rotor circuit is closed). The rotor currents create their own magnetic field. The interaction of stator RMF and rotor field produces electromagnetic torque (Lorentz force) in the direction of RMF, so the rotor accelerates. It can never reach synchronous speed in steady state because then slip and induced rotor EMF would be zero, giving zero torque.
  • Equivalent circuit (stator-referred, per phase)

    • Elements:
      • Stator resistance (R₁) and stator leakage reactance (X₁) in series represent stator copper loss and leakage.
      • Magnetising branch: R_c (core loss resistance) in parallel with X_m (magnetising reactance) represents core (iron) loss and magnetising current.
      • Referred rotor circuit: R₂′/s in series with X₂′, where R₂′ and X₂′ are rotor parameters referred to stator, and s is slip. The term R₂′/s models that air-gap power increases as slip increases.
    • Often, for torque and slip calculations, the magnetising branch is moved to the supply and replaced by Thevenin equivalent seen from the air gap.
    • What to draw: Per-phase equivalent circuit: Vs feeding R₁ + jX₁, then a shunt branch R_c || jX_m to neutral, then series rotor branch R₂′/s + jX₂′ to neutral. Label each element clearly.
  • Power flow and losses

    • Definition: Input power (P_in) is the three-phase electrical power drawn from the supply.
    • Stator copper and core losses reduce this to the air-gap power (P_g) transferred to the rotor magnetic field.
    • The rotor copper loss equals s·P_g.
    • The mechanical power developed (P_m) (air-gap power converted to mechanical form) equals P_g·(1 − s).
    • Subtract mechanical (rotational) losses (friction, windage, stray) from P_m to get the shaft output power (P_out). Efficiency η = P_out/P_in.
    • What to draw: Power-flow block diagram: P_in → (− stator losses) → P_g → split into rotor copper loss s·P_g and mechanical power P_m = (1−s)·P_g → (− rotational losses) → P_out.
  • Torque and torque–slip characteristic

    • Definition: Electromagnetic torque (T_e) is the torque developed by the machine’s electromagnetic interaction, equal to P_m/ω_m, where ω_m is mechanical angular speed in rad/s.
    • In a simplified model neglecting stator impedance and core loss, torque is approximately:
      • T ∝ (s·E₂²·R₂) / (R₂² + (s·X₂)²), where E₂ is rotor EMF at standstill per phase, R₂ and X₂ are rotor standstill resistance and leakage reactance per phase. This shows: for small s, torque ∝ s; near s = 1, torque decreases because reactance dominates.
    • Using Thevenin equivalent (more accurate):
      • T = [3·V_th²·(R₂′/s)] / {ω_s·[(R_th + R₂′/s)² + (X_th + X₂′)²]} where V_th, R_th, X_th are stator Thevenin parameters, and ω_s = 2·π·N_s/60 is synchronous mechanical angular speed in rad/s.
    • Condition for maximum torque (pull-out or breakdown torque): occurs when R₂′/s = √(R_th² + (X_th + X₂′)²) (from dT/ds = 0). In the very-simplified case with R_th ≈ 0, X_th ≈ 0, it reduces to s_max = R₂′/X₂′. The approximate maximum torque magnitude is independent of rotor resistance (in the neglected-stator-impedance model), but the slip at which it occurs varies with rotor resistance.
    • Characteristic shape: torque starts at zero at s = 0, rises approximately linearly with s at low slip, peaks at s ≈ s_max (breakdown torque), then decreases to the finite starting torque at s = 1 (nonzero).
    • What to draw: T–s curve from s = 0 to 1 with marked normal operating region (small s ~ 0.01–0.05), peak at s_max, and starting torque at s = 1.
  • Starting methods (overview)

    • Direct-on-line (DOL): full voltage applied; simple, high starting current (~5–8× rated), good for small motors and stiff supplies.
    • Star–delta starter: starts in star to reduce phase voltage to V/√3, then switches to delta; reduces starting current and torque to ~1/3 of DOL.
    • Autotransformer starter: taps provide reduced voltage with better torque-per-ampere than star–delta; used for larger motors.
    • Rotor resistance starter (slip-ring): external resistances increase starting torque and limit current; resistance is cut out as speed rises.
    • Soft starter (thyristor-based) and VFD (variable frequency drive): control voltage/frequency for smooth start and speed control; VFD keeps V/f constant to maintain flux.
    • Reversing rotation: interchange any two stator line connections to reverse the phase sequence; the RMF reverses and the motor runs in the opposite direction. Use a reversing starter or VFD; do not swap phases while the motor is running.
  • Nameplate and selection basics

    • Key data: rated power (kW), voltage (V), current (A), frequency (Hz), speed (rpm), power factor, efficiency, duty type, insulation class, enclosure (IP), and number of poles (implied from speed at 50 Hz).
    • Approximate pole count from near-synchronous speed: 2-pole ~ 3000 rpm at 50 Hz, 4-pole ~ 1500 rpm, 6-pole ~ 1000 rpm, 8-pole ~ 750 rpm (actual rated speed lower due to slip).
  • Assumptions commonly used in derivations

    • Balanced three-phase supply and windings.
    • Sinusoidal distributed windings (fundamental only).
    • Stator impedance neglected for simple torque–slip formulae (state clearly when used).
    • Constant mechanical losses independent of load (approximation for power flow problems).

Formulas

  • f_2 = s·f_1 — Rotor current frequency in hertz; f_1 is stator frequency.
  • ω_s = 2·π·N_s/60 — Synchronous mechanical angular speed in rad/s.
  • ω_m = 2·π·N/60 = (1 − s)·ω_s — Rotor mechanical angular speed in rad/s.
  • P_g = 3·I_2′²·(R_2′/s) — Air-gap power in watts; I_2′ rotor current referred to stator in amperes; R_2′ in ohms. Assumes per-phase stator-referred equivalent.
  • Rotor copper loss = 3·I_2′²·R_2′ = s·P_g — In watts.
  • P_m = P_g·(1 − s) — Mechanical power developed in watts.
  • η = P_out/P_in — Efficiency (dimensionless). P_out shaft output power.
  • T_e = P_m/ω_m — Electromagnetic torque in newton-metre (N·m).
  • T ≈ K·(s·E_2²·R_2) / (R_2² + (s·X_2)²) — Simplified torque–slip relation; K is a constant depending on frequency and poles; E_2, R_2, X_2 as defined at standstill (per phase). Applies when stator impedance neglected.
  • T = [3·V_th²·(R_2′/s)] / {ω_s·[(R_th + R_2′/s)² + (X_th + X_2′)²]} — Torque using Thevenin parameters; SI units give N·m if volts, ohms, and rad/s are used.
  • s_max = R_2′ / √(R_th² + (X_th + X_2′)²) — Slip at maximum torque (from dT/ds = 0). In the simplified case with small R_th and X_th, s_max ≈ R_2′/X_2′.
  • T_max = [3·V_th²] / [2·ω_s·(X_th + X_2′)] — Approximate maximum torque magnitude when R_th ≈ 0 (independent of R_2′); use with caution and state assumptions.
  • T (N·m) = 9550·P(kW)/N(rpm) — Shaft torque from output power and speed; valid for steady state.

Worked examples

  1. Speed, slip, and rotor frequency Given: A 3-phase, 50 Hz, 4-pole induction motor runs at 1440 rpm under load. Find synchronous speed N_s, slip s, and rotor current frequency f_2.

Steps:

  1. Synchronous speed formula: N_s = 120·f/P = 120·50/4 = 1500 rpm.
  2. Slip: s = (N_s − N)/N_s = (1500 − 1440)/1500 = 60/1500 = 0.04 (dimensionless) = 4%.
  3. Rotor frequency: f_2 = s·f_1 = 0.04·50 = 2 Hz.

Answer: N_s = 1500 rpm; s = 0.04 (4%); f_2 = 2 Hz. Bold final: N_s = 1500 rpm; s = 4%; f_2 = 2 Hz.

  1. Shaft torque from rated output and speed Given: A 15 kW, 3-phase, 50 Hz induction motor has rated speed 1460 rpm. Find the shaft torque at rated output.

Steps:

  1. Use torque–power–speed relation: T = 9550·P(kW)/N(rpm).
  2. Substitute: T = 9550·15/1460 = 143250/1460 N·m ≈ 98.1 N·m.

Answer: Shaft torque ≈ 98.1 N·m. Bold final: 98.1 N·m.

  1. Power flow, torque, and speed at given slip Given: A 3-phase induction motor draws P_in = 30 kW. Stator losses (copper + core) = 2 kW. Rotational (mechanical) losses = 1 kW. The motor is 4-pole, 50 Hz, operating at slip s = 0.05. Find: (a) air-gap power P_g, (b) rotor copper loss, (c) mechanical power developed P_m, (d) shaft output power P_out, (e) speed N, and (f) shaft torque T.

Steps:

  1. Air-gap power: P_g = P_in − stator losses = 30 − 2 = 28 kW.
  2. Rotor copper loss: = s·P_g = 0.05·28 = 1.4 kW.
  3. Mechanical power developed: P_m = P_g·(1 − s) = 28·0.95 = 26.6 kW.
  4. Shaft output power: P_out = P_m − rotational losses = 26.6 − 1 = 25.6 kW.
  5. Synchronous speed: N_s = 120·f/P = 120·50/4 = 1500 rpm. Rotor speed: N = (1 − s)·N_s = 0.95·1500 = 1425 rpm.
  6. Shaft torque: T = 9550·P_out(kW)/N(rpm) = 9550·25.6/1425 N·m.
    • Compute numerator: 9550·25.6 = 244480.
    • Divide: 244480/1425 ≈ 171.7 N·m.

Answer: (a) P_g = 28 kW; (b) rotor Cu loss = 1.4 kW; (c) P_m = 26.6 kW; (d) P_out = 25.6 kW; (e) N = 1425 rpm; (f) T ≈ 171.7 N·m. Bold final: P_out = 25.6 kW; N = 1425 rpm; T = 171.7 N·m.

Common mistakes

  • Using frequency in rad/s in the N_s formula, or mixing rpm and rps without conversion.
  • Calculating rotor frequency f_2 as (1 − s)·f_1 instead of s·f_1.
  • Treating rotor copper loss as (1 − s)·P_g instead of s·P_g.
  • Using output power in P_g = 3·I_2′²·(R_2′/s); this formula gives air-gap power, not shaft power.
  • Quoting T_max or s_max without clearly stating the assumptions (e.g., neglecting stator impedance) under which those expressions are valid.
  • Forgetting units or not converting rpm to rad/s when using T = P_m/ω_m.
  • Drawing incomplete diagrams: not labelling R₁, X₁, R_c, X_m, R₂′/s, X₂′ in the equivalent circuit; not marking s and T_max on torque–slip plot.

For your exam

  • Derivations: RMF and its speed N_s = 120·f/P; f_2 = s·f_1; torque–slip relationship using simplified and/or Thevenin equivalent; condition for maximum torque and dependence on rotor resistance; power-flow relations P_g, s·P_g, (1 − s)·P_g.
  • Numericals: compute N_s, s, f_2; compute torque from power and speed; compute air-gap power, rotor losses, mechanical output; estimate s_max and T_max from given parameters.
  • Diagrams: per-phase equivalent circuit with all labels; T–s characteristic with operating region and breakdown torque; RMF phasors/winding axes; power-flow block diagram. A full-marks answer includes clearly drawn, labelled diagrams, correct formulas with units, explicit assumptions, and neat step-by-step calculations.

Quick check

  1. A 6-pole, 50 Hz motor runs at 970 rpm. What are N_s, s, and f_2?
  2. Why does increasing external rotor resistance in a slip-ring motor increase starting torque but not T_max (approximately)?
  3. State the relation between P_g, rotor copper loss, and P_m.

Answers: 1) N_s = 120·50/6 = 1000 rpm; s = (1000 − 970)/1000 = 0.03 = 3%; f_2 = 0.03·50 = 1.5 Hz. 2) Increasing rotor resistance shifts s_max ≈ R₂′/X₂′ to a higher slip, improving torque at s = 1 (start), while in the simplified model T_max ≈ constant and independent of R₂′; stator impedance neglected. 3) P_g is split as rotor copper loss = s·P_g and mechanical power developed P_m = (1 − s)·P_g.

Finished this topic? Mark it so your progress, study plan and readiness keep up.

Stuck on something here?