DC machines: basics
DC machines: parts, EMF/torque equations, types (generator/motor; shunt/series/compound), speed–torque relations, losses/efficiency, armature reaction and commutation, and standard numericals.
Drafted with Aria, reviewed by the AiCanCode.org team · Updated . How we write and check our notes. Spotted an error? Use Give Feedback at the bottom of the page.
Why it matters
DC machines convert energy between electrical DC and mechanical rotation. You will meet them in older traction, cranes, rolling mills, steel plants, battery charging, laboratory drives, and as teaching platforms to understand electromechanical energy conversion before AC machines and power electronics.
Key ideas
Construction of a DC machine (what to draw and label):
- Draw a cross-sectional sketch of a cylindrical frame. Label:
- Yoke (outer frame): magnetic return path and mechanical support; made of cast steel or rolled steel.
- Pole core and pole shoe: carry and spread flux; bolted to yoke.
- Field windings (excitation coils): wound on pole cores; produce the main magnetic field when excited by DC.
- Armature core: cylindrical laminated iron on the shaft; slots on surface to house conductors; laminations reduce eddy-current loss.
- Armature winding: conductors in slots connected into coils and commutated to form lap or wave winding.
- Commutator: cylindrical stack of copper segments insulated by mica; converts the internal AC in armature coils to external DC (in generator) and vice versa in motor.
- Brushes: carbon/graphite blocks pressed on commutator to collect/deliver current.
- Show direction of rotation ω, and mark one set of brushes across commutator.
- Draw a cross-sectional sketch of a cylindrical frame. Label:
Operation principle:
- Generator action: By Faraday’s law (from Electromagnetic induction topic), a conductor of length l cutting magnetic flux density B at velocity v has induced emf
e = B · l · v(for one conductor). In an armature with many conductors, these emfs add appropriately. - Motor action: By Lorentz force, a current-carrying conductor in magnetic field experiences force
F = B · I · l(per conductor); the distributed conductors produce torque on the rotor. - DC machines use a commutator to maintain unidirectional terminal voltage/current, although internally the armature coil voltages are alternating due to rotation.
- Generator action: By Faraday’s law (from Electromagnetic induction topic), a conductor of length l cutting magnetic flux density B at velocity v has induced emf
Lap and wave winding:
- Lap winding: Each coil laps back to the next commutator segment; number of parallel paths
A = P(equal to number of poles). Used for high-current, low-voltage applications. - Wave winding: Coils progress in a wave around the armature; number of parallel paths
A = 2. Used for low-current, high-voltage applications.
- Lap winding: Each coil laps back to the next commutator segment; number of parallel paths
Generated emf (EMF) equation of a DC generator (derivation outline commonly asked):
- Flux per pole = Φ Wb; number of poles = P; total conductors = Z; speed = N rpm; number of parallel paths = A (dimensionless). Conductors in series per path
= Z/A. - Total flux cut per revolution by one conductor =
P · Φ(passes under P poles per revolution). - Time per revolution =
60/Ns; average emf per conductor= (flux cut per rev)/(time per rev) = (P · Φ)/(60/N) = (P · Φ · N)/60volts. - Generated emf of armature (across brushes)
E = (emf per conductor) × (conductors in series per path) = (P · Φ · N/60) × (Z/A). - Final exact statement:
E = (P · Φ · Z · N)/(60 · A)volts, neglecting brush drop and assuming uniform flux and no armature reaction.
- Flux per pole = Φ Wb; number of poles = P; total conductors = Z; speed = N rpm; number of parallel paths = A (dimensionless). Conductors in series per path
Back emf in a DC motor:
- When a DC voltage is applied to the armature, it rotates and the same EMF mechanism induces an emf opposing the applied voltage (Lenz’s law). This is the back emf
E_b. In steady operation,E_bnearly equals the applied voltage minus the armature IR drop. Magnitude is given by the same EMF equation with speed and flux.
- When a DC voltage is applied to the armature, it rotates and the same EMF mechanism induces an emf opposing the applied voltage (Lenz’s law). This is the back emf
Torque equation of a DC motor (derivation commonly asked):
- Electrical power converted to mechanical (air-gap power)
P_conv = E_b · I_a(neglecting brush drop), whereI_ais armature current. - Mechanical power
P_mech = T · ω, whereTis torque (N·m),ωis angular speed (rad/s) withω = 2πN/60. - With
E_b = (P · Φ · Z · N)/(60 · A), equate powers:T · ω = E_b · I_a. Substituteωand simplify;Ncancels. - Final exact statement:
T = (P · Z · Φ · I_a)/(2π · A)newton–metre, assuming uniform field and current distribution, neglecting saturation and armature reaction.
- Electrical power converted to mechanical (air-gap power)
Speed relations:
- For a shunt motor with approximately constant flux (field current nearly constant), speed
N ∝ E_b/Φ ≈ (V − I_a R_a)/Φ. If Φ is constant,N ≈ k · (V − I_a R_a), whereR_ais armature resistance. - For a series motor,
Φis approximately proportional toI_aat low currents (before saturation). HenceN ∝ (V − I_a R_a)/Φ ≈ (V − I_a R_a)/I_a. This gives high starting torque and strong speed drop with load. In saturation region, Φ tends to constant.
- For a shunt motor with approximately constant flux (field current nearly constant), speed
Types of DC machines by excitation:
- Separately excited: Field winding fed from an independent DC source.
- Shunt: Field winding in parallel with armature; high speed regulation, medium starting torque.
- Series: Field winding in series with armature; very high starting torque, poor speed regulation, never run without load.
- Compound: Both shunt and series windings on poles; can be cumulative (series aids shunt) or differential (series opposes shunt). Long-shunt and short-shunt connections exist.
Armature reaction (basic): The effect of armature current’s own MMF on the main field. It distorts the main field, weakening it under some pole tips and strengthening under others, shifting the magnetic neutral axis (MNA). Effects: sparking at brushes, reduced generated emf. Mitigation: brush shift (not ideal), interpoles (commutating poles), compensating windings.
Commutation: The process of current reversal in a coil short-circuited by a brush as the commutator rotates. Ideal commutation is sparkless. Aiding methods: small brush shift to align with MNA, using interpolar (commutating) poles carrying armature current to induce a reversing emf, and high-resistivity brushes. Poor commutation causes sparking and commutator wear.
Losses and efficiency:
- Copper losses: armature I²R (
I_a² R_a), field copper (I_f² R_f), series field copper if any. - Iron (core) losses: hysteresis loss (
∝ B_max^n · f, with n ≈ 1.6–2.0) and eddy-current loss (∝ B_max^2 · f^2), reduced by laminations. - Mechanical losses: friction and windage; and brush contact drop (small voltage drop at brushes) sometimes accounted separately.
- Input − losses = output. Efficiency
η = output/input.
- Copper losses: armature I²R (
Characteristic curves (names only at basics level):
- Generator: open-circuit characteristic (OCC), internal and external characteristics.
- Motor: torque–current (T–I), speed–torque (N–T), speed–current (N–I) characteristics, differing by type (shunt/series/compound).
Formulas
E = (P · Φ · Z · N)/(60 · A) — Generated emf or back emf; E in volt (V), P = number of poles (dimensionless), Φ = flux per pole in weber (Wb), Z = total armature conductors (dimensionless), N = speed in revolutions per minute (rpm), A = number of parallel paths (dimensionless). Applies to DC armature with uniform flux; lap: A = P, wave: A = 2.
E_b = V − I_a · R_a − V_brush — Back emf in a motor; E_b in V, V = applied armature voltage (V), I_a = armature current (A), R_a = armature resistance (Ω), V_brush = total brush drop (V). Often V_brush is small and neglected in basic numericals. For a generator, terminal equation: V = E − I_a · R_a − V_brush (E is generated emf).
T = (P · Z · Φ · I_a)/(2π · A) — Electromagnetic torque; T in newton–metre (N·m), P, Z, Φ, I_a, A as above. Applies to DC motors under stated assumptions.
ω = 2π · N/60 — Angular speed; ω in rad/s, N in rpm. General kinematics relation.
N ∝ E_b/Φ — Speed proportionality; N in rpm, E_b in V, Φ in Wb. For shunt motor with nearly constant Φ, N ≈ k · (V − I_a R_a).
P_conv = E_b · I_a — Power converted across the air gap; P_conv in watt (W). Neglects brush drop.
P_out = T_shaft · ω — Mechanical output power; P_out in W, T_shaft in N·m, ω in rad/s. Electromagnetic (developed) torque T_dev satisfies P_conv = T_dev · ω and is greater than T_shaft by the torque required to overcome rotational (mechanical and core) losses.
η = P_out/P_in — Efficiency (dimensionless). P_out and P_in in W. Applies to generator or motor with appropriate definitions of input/output.
A = P (lap winding) — Number of parallel paths equals number of poles; dimensionless. Applies to simplex lap winding.
A = 2 (wave winding) — Number of parallel paths equals two; dimensionless. Applies to simplex wave winding.
Worked examples
Example 1: Generated emf of a DC generator (wave-wound) Given: P = 4, Φ = 0.02 Wb per pole, Z = 480 conductors, A = 2 (wave winding), N = 600 rpm. Find the generated emf E.
Steps:
- Formula:
E = (P · Φ · Z · N)/(60 · A). - Substitute with units:
E = (4 · 0.02 Wb · 480 · 600 rpm)/(60 · 2)V. - Compute numerator: 4 · 0.02 = 0.08; 0.08 · 480 = 38.4; 38.4 · 600 = 23040.
- Denominator: 60 · 2 = 120.
- E = 23040/120 = 192 V.
Final answer: E = 192 V.
Example 2: DC shunt motor speed and torque at two loads
A 220 V DC shunt motor has R_a = 0.20 Ω, shunt field resistance R_sh = 110 Ω. At Load 1, the line current is 20 A and the speed is 1200 rpm. Find (a) speed and (b) torque at Load 2 when the line current is 40 A. Neglect brush drop; assume Φ is constant (no saturation change). We compute electromagnetic (developed) torque using T = P_conv/ω; shaft torque would be slightly lower if rotational losses were included.
Given: V = 220 V; R_a = 0.20 Ω; R_sh = 110 Ω; N1 = 1200 rpm; I_L1 = 20 A; I_L2 = 40 A. Field current I_sh = V/R_sh = 220/110 = 2.0 A (constant). Armature currents: I_a1 = I_L1 − I_sh = 18 A; I_a2 = I_L2 − I_sh = 38 A.
(a) Speed at Load 2:
- Back emf at Load 1:
E1 = V − I_a1 R_a = 220 − (18)(0.20) = 220 − 3.6 = 216.4 V. - Back emf at Load 2:
E2 = V − I_a2 R_a = 220 − (38)(0.20) = 220 − 7.6 = 212.4 V. - With constant Φ,
N ∝ E_b. ThereforeN2 = N1 · (E2/E1) = 1200 · (212.4/216.4). - Compute ratio: 212.4/216.4 ≈ 0.9815. Hence N2 ≈ 1200 · 0.9815 = 1177.8 rpm.
Speed at Load 2: ≈ 1178 rpm.
(b) Torque at both loads (for completeness):
- Angular speeds:
ω1 = 2πN1/60 = 2π·1200/60 = 2π·20 = 40π ≈ 125.6637 rad/s. For Load 2,ω2 = 2π·1177.8/60 ≈ 123.37 rad/s. - Converted power:
P_conv1 = E1 I_a1 = 216.4 · 18 = 3895.2 W.P_conv2 = E2 I_a2 = 212.4 · 38 = 8071.2 W. - Torques:
T1 = P_conv1/ω1 = 3895.2/125.6637 ≈ 31.0 N·m.T2 = P_conv2/ω2 = 8071.2/123.37 ≈ 65.4 N·m.
Torque at Load 1: ≈ 31.0 N·m; Torque at Load 2: ≈ 65.4 N·m.
Example 3: Required conductors for a lap-wound generator A 6-pole DC generator is lap-wound. It must generate 250 V at 500 rpm with flux per pole Φ = 0.03 Wb. Find the total number of armature conductors Z. For lap winding, A = P = 6.
Steps:
- Formula rearranged:
Z = (60 · A · E)/(P · Φ · N). - Substitute:
Z = (60 · 6 · 250 V)/(6 · 0.03 Wb · 500 rpm). - Compute numerator: 60 · 6 · 250 = 90000. Denominator: 6 · 0.03 · 500 = 90.
- Z = 90000/90 = 1000 conductors.
Final answer: Z = 1000 conductors.
Common mistakes
- Using rpm directly in power or torque formulas without converting to rad/s when needed; always use
ω = 2πN/60for torque calculations. - Forgetting to subtract shunt field current when finding armature current in a shunt motor:
I_a = I_L − I_sh. - Assuming Φ is strictly constant at all currents; near saturation, Φ changes little with field current, but at low field current it is roughly proportional. State assumptions in speed problems.
- Using lap A = 2 and wave A = P (reversed). Correct is: lap A = P; wave A = 2.
- Ignoring brush drop in precision voltage calculations when asked to include it; read the question. If not given, you may neglect it but mention the assumption.
- In EMF derivation, forgetting the factor of 60 when converting rpm to rps, leading to a 60× error.
- In torque derivation, not cancelling N correctly and getting T dependent on speed; correct torque equation is independent of speed for given Φ and I_a.
For your exam
- Short notes: Constructional features of DC machines; causes of sparking and remedies; types of DC motors and their characteristics; losses and efficiency. Include key points, assumptions, and one small sketch description if applicable.
- Derivations: EMF equation
E = (P Φ Z N)/(60 A)step-by-step; torque equationT = (P Z Φ I_a)/(2π A)from power balance; speed equation for shunt motorN ∝ (V − I_a R_a)/Φstating assumptions. Show each step clearly and track units. - Numericals: Compute generated emf, required conductors, speed change with load, torque for given current and flux, efficiency from given losses. Start with the formula, substitute with units, compute carefully, and state the final answer in bold with units.
- Diagrams: Cross-sectional view of a DC machine with yoke, poles, armature, commutator, brushes; commutator–brush arrangement; flux distribution showing armature reaction and MNA shift. Describe what you will draw and label items.
To get full marks: define terms precisely, list assumptions, derive cleanly with correct factors (60, 2π), explain physical meaning briefly, and present numbers with units and a justified approximation (e.g., neglecting brush drop) if used.
Quick check
- In a simplex wave-wound 8-pole DC armature with 512 conductors running at 750 rpm and Φ = 0.025 Wb, what is the generated emf? State A and the formula you use.
- Why must a DC series motor not be run without mechanical load?
- Write the torque equation of a DC motor and name each symbol with its SI unit.
Answers: 1) A = 2, E = (P Φ Z N)/(60 A) = (8·0.025·512·750)/(60·2) ≈ 640 V (check arithmetic when writing in exam); 2) Because Φ ∝ I_a at low current, with no load I_a is small so speed N ∝ (V − I_a R_a)/Φ becomes very high (dangerous overspeed); 3) T = (P · Z · Φ · I_a)/(2π · A), where T in N·m, P dimensionless, Z dimensionless, Φ in Wb, I_a in A, A dimensionless.
Finished this topic? Mark it so your progress, study plan and readiness keep up.
Stuck on something here?