First Year Engineering is coming soon

We're still writing and reviewing the notes for every subject, and we'll open it when every subject is ready. Meanwhile you can practise aptitude, ask Aria about any subject, or see the branches that are ready.

Resonance

Resonance in AC series and parallel RLC circuits: condition for resonance, quality factor, bandwidth, selectivity, half-power frequencies, and current/voltage magnification.

Drafted with Aria, reviewed by the AiCanCode.org team · Updated . How we write and check our notes. Spotted an error? Use Give Feedback at the bottom of the page.

Why it matters

Resonance lets circuits select one frequency while rejecting others. Engineers use it in radio tuners, filters, oscillators, induction heating, power-factor correction, and to avoid dangerous overcurrents or overvoltages in power systems.

Key ideas

  • Exact statement: “In a series RLC circuit, resonance occurs when inductive reactance equals capacitive reactance (X_L = X_C), i.e., when ω₀L = 1/(ω₀C), hence ω₀ = 1/√(LC). At resonance, the circuit’s impedance is minimum and equal to R, the current is maximum, and the power factor is unity.”

  • At resonance, large and equal-magnitude voltages appear across L and C (180° out of phase), while the supply voltage equals the resistor’s drop. This is called voltage magnification.

  • Half-power (−3 dB) points for series RLC occur when the magnitude of reactance equals R: |ωL − 1/ωC| = R. They define the bandwidth.

  • Parallel RLC circuit (tank circuit) — L and C are connected in parallel across the source. Practical inductors have series resistance r (winding loss). The input admittance is Y = G + j(B_L + B_C) where G is conductance (from losses), B_L is inductive susceptance, B_C is capacitive susceptance. In the common practical model with an inductor of L in series with r, in parallel with a capacitor C, the resonance (anti-resonance) occurs when net susceptance is zero. For small r (high Q), the resonant frequency is approximately ω₀ ≈ 1/√(L·C). At resonance the input impedance is maximum (ideally very large), and the supply current is minimum while large, opposite branch currents circulate between L and C. This is called current magnification.

    • Exact statement (idealized): “In a parallel RLC circuit with negligible losses, resonance occurs when the inductive susceptance equals the capacitive susceptance in magnitude and is opposite in sign, i.e., ω₀C = 1/(ω₀L), hence ω₀ = 1/√(LC). At resonance the input admittance is purely real and minimum; thus, the input impedance is maximum.”
    • With a realistic inductor of series resistance r, the impedance at resonance is finite and large; its approximate value (dynamic resistance) is R_p ≈ L/(C·r) when r is small.
  • Quality factor (Q) — A dimensionless measure of energy storage relative to energy dissipation per cycle; it also measures selectivity (sharpness) of resonance.

    • For a series RLC at resonance: Q = ω₀L / R = 1/(ω₀CR).
    • For a parallel resonant circuit (high-Q approximation): Q = R_p / (ω₀L) = ω₀C·R_p, where R_p is the equivalent parallel (dynamic) resistance at resonance.
    • High Q implies narrow bandwidth and stronger voltage (series) or current (parallel) magnification.
  • Bandwidth (BW) and selectivity — The bandwidth is the frequency interval between the two half-power frequencies (f₂ − f₁). For high-Q RLC circuits:

    • Series: BW = R / (2πL) (in hertz), or BW_rad = R / L (in rad/s).
    • Parallel (high-Q): BW = 1 / (2πR_pC) (in hertz), or BW_rad = 1 / (R_pC) (in rad/s).
    • For both types (high-Q), Q ≈ f₀ / BW = ω₀ / BW_rad.
  • Half-power frequencies — Defined where the average power is half the maximum at resonance. For series RLC, at the half-power points the current magnitude drops to I_max/√2, and |ωL − 1/ωC| = R. The exact angular frequencies are the two positive roots of LC·ω² ∓ RC·ω − 1 = 0 (details under formulas and examples). For parallel RLC, the input impedance at these points drops to Z_max/√2 (high-Q approximation) and the supply current increases to √2 times its minimum.

  • Voltage and current magnification — At resonance:

    • Series: |V_L| = |V_C| = Q·V_source (approx., for sufficiently high Q). The series current is maximum.
    • Parallel: The circulating branch currents are large and approximately Q times the supply current, i.e., |I_L| ≈ |I_C| ≈ Q·I_source (high-Q).
  • What to draw in exams:

    • Series resonance circuit: draw a sinusoidal AC source, then R, L, C in series. Label R (Ω), L (H), C (F), source V (rms). Phasor diagram at resonance: draw current I as reference along +x. Draw V_R in phase with I, and equal-length V_L and V_C 180° apart on the ±y-axis so that they cancel; resultant V equals V_R.
    • Parallel resonance (tank): draw AC source across two parallel branches: left branch inductor L with small series resistor r, right branch capacitor C. Label all. Phasor diagram: take source voltage V as reference on +x. Draw I_L lagging V by slightly less than 90° (due to r), draw I_C leading V by 90°, with magnitudes nearly equal and opposite so their reactive parts cancel; small supply current Is is their vector sum at resonance.

Assumptions commonly used:

  • Sinusoidal steady-state, linear lumped components.
  • For “high-Q” approximations: R ≪ ω₀L and 1/(ω₀C) ≫ R in series; or inductor loss r is small so ω₀L ≫ r in parallel.

Formulas

Z_series = R + j(ωL − 1/(ωC))

  • Z_series: series impedance (Ω). ω in rad/s, L in H, C in F. Applies to series RLC.

Condition for series resonance: ω₀L = 1/(ω₀C) ⇒ ω₀ = 1/√(L·C)

  • ω₀: resonant angular frequency (rad/s), L (H), C (F). Series or parallel lossless resonance.

At series resonance: Z = R, I_max = V/R, power factor = 1

  • V: rms source voltage (V), I_max (A), R (Ω). Applies at ω = ω₀ in series RLC.

Series half-power condition: |ωL − 1/(ωC)| = R

  • Defines half-power angular frequencies ω₁, ω₂ for series RLC.

Exact ω at half-power (series): LC·ω² − RC·ω − 1 = 0 (upper), LC·ω² + RC·ω − 1 = 0 (lower)

  • Solve for ω₂ (upper root) and ω₁ (lower root), respectively. L (H), C (F), R (Ω).

Bandwidth (series, rad/s): BW_rad = ω₂ − ω₁ = R/L

  • Exact for any series RLC; independent of C. L in H, R in Ω.

Bandwidth (series, Hz): BW = R/(2πL)

  • BW in hertz. Valid for series RLC.

Quality factor (series): Q = ω₀L/R = 1/(ω₀CR)

  • Dimensionless. At ω₀ for series RLC.

Voltage magnification (series): |V_L| = |V_C| = Q·V

  • Exact at resonance for ideal series RLC (any Q). V is source rms (V); V_L, V_C are rms (V) at resonance.

Y_parallel = G + j(ωC − 1/(ωL)) (idealized L, C; G is total conductance)

  • Input admittance of parallel RLC (S). ω in rad/s, L in H, C in F. For practical inductor with series r, use small-loss approximation.

Condition for parallel resonance (idealized): ω₀C = 1/(ω₀L) ⇒ ω₀ = 1/√(L·C)

  • Lossless or high-Q approximation.

Dynamic resistance at parallel resonance (high-Q inductor with series r): R_p ≈ L/(C·r)

  • R_p in Ω, L in H, C in F, r in Ω. Valid when r ≪ ω₀L.

Quality factor (parallel): Q = R_p/(ω₀L) = ω₀C·R_p

  • Dimensionless. High-Q parallel resonance.

Bandwidth (parallel, rad/s): BW_rad = 1/(R_p·C)

  • High-Q parallel RLC.

Bandwidth (parallel, Hz): BW = 1/(2πR_p·C)

  • BW in hertz. High-Q approximation.

Selectivity (high-Q): Q ≈ f₀/BW = ω₀/BW_rad

  • Dimensionless relation linking Q, resonant frequency, and bandwidth.

Current magnification (parallel, high-Q): |I_L| ≈ |I_C| ≈ Q·I_source at resonance

  • I_source is supply current (A). High-Q tank.

Worked examples

Example 1 — Series RLC: f₀, Q, voltages at resonance, bandwidth, and half-power frequencies Given: R = 10 Ω, L = 50 mH, C = 100 µF, source V = 100 V rms.

  1. Resonant angular frequency and frequency: Formula: ω₀ = 1/√(L·C), f₀ = ω₀/(2π) Numbers: L·C = 0.05 H × 100×10⁻⁶ F = 5×10⁻⁶ √(L·C) = √(5×10⁻⁶) = 2.236×10⁻³ ω₀ = 1 / 2.236×10⁻³ = 447.2 rad/s f₀ = 447.2 / (2π) = 71.2 Hz
  2. Quality factor: Formula: Q = ω₀L / R Numbers: Q = 447.2×0.05 / 10 = 22.36 / 10 = 2.236
  3. Current and component voltages at resonance: Formulae: I_max = V / R, |V_L| = I_max·ω₀L, |V_C| = I_max·(1/(ω₀C)) = |V_L| Numbers: I_max = 100 V / 10 Ω = 10 A |V_L| = 10 × 447.2 × 0.05 = 223.6 V |V_C| = 223.6 V Check: |V_L| = |V_C| = Q·V = 2.236 × 100 V = 223.6 V (consistent)
  4. Bandwidth (Hz): Formula: BW = R / (2πL) Numbers: BW = 10 / (2π×0.05) = 10 / 0.31416 = 31.83 Hz Selectivity: f₀/BW = 71.2 / 31.83 ≈ 2.24 ≈ Q (as expected for series)
  5. Half-power frequencies (exact): Condition: |ωL − 1/(ωC)| = R, equivalently the quadratics: Upper: LC·ω² − RC·ω − 1 = 0; Lower: LC·ω² + RC·ω − 1 = 0 Parameters: L·C = 5×10⁻⁶, R·C = 10 × 100×10⁻⁶ = 1.0×10⁻³ Discriminant: (R·C)² + 4LC = (1.0×10⁻³)² + 4×5×10⁻⁶ = 1.0×10⁻⁶ + 2.0×10⁻⁵ = 2.1×10⁻⁵ √Discriminant = 4.582×10⁻³ Roots (rad/s): ω₂ = [RC + √]/(2LC) = (1.0×10⁻³ + 4.582×10⁻³) / (1.0×10⁻⁵) = 558.2 rad/s ω₁ = [−RC + √]/(2LC) = (−1.0×10⁻³ + 4.582×10⁻³) / (1.0×10⁻⁵) = 358.2 rad/s Convert to Hz: f₂ = 558.2 / (2π) = 88.88 Hz; f₁ = 358.2 / (2π) = 57.03 Hz Bandwidth check: f₂ − f₁ = 31.85 Hz ≈ 31.83 Hz (matches formula) Final answers: f₀ = 71.2 Hz, Q = 2.236, I_max = 10 A, |V_L| = |V_C| = 223.6 V, BW = 31.83 Hz, f₁ = 57.03 Hz, f₂ = 88.88 Hz.

Example 2 — Parallel resonance (tank) with realistic inductor: f₀, Q, dynamic resistance, BW, and current magnification Given: Inductor L = 50 mH with series resistance r = 5 Ω, capacitor C = 0.10 µF, source V = 10 V rms.

  1. Resonant angular frequency and frequency (high-Q approximation): Formula: ω₀ ≈ 1/√(L·C), f₀ = ω₀/(2π) Numbers: L·C = 0.05 H × 0.10×10⁻⁶ F = 5×10⁻⁹ √(L·C) = √(5×10⁻⁹) = 7.071×10⁻⁵ ω₀ ≈ 1 / 7.071×10⁻⁵ = 14142 rad/s f₀ = 14142 / (2π) = 2250 Hz Note: The exact resonant frequency is ω₀' = √(1/LC − r²/L²) for this model; since r ≪ ω₀L here, ω₀' is very close to 14142 rad/s.
  2. Dynamic (parallel) resistance at resonance: Formula (high-Q inductor): R_p ≈ L/(C·r) Numbers: R_p ≈ 0.05 / (0.10×10⁻⁶ × 5) = 0.05 / 5×10⁻⁷ = 1.0×10⁵ Ω
  3. Quality factor (equivalent parallel): Formulae: Q = R_p/(ω₀L) = ω₀C·R_p Numbers: Q = 1.0×10⁵ / (14142 × 0.05) = 1.0×10⁵ / 707.1 = 141.4 Also, Q = 14142 × 0.10×10⁻⁶ × 1.0×10⁵ = 141.4 (consistent)
  4. Bandwidth (Hz): Formula: BW = 1/(2πR_p·C) Numbers: BW = 1 / (2π × 1.0×10⁵ × 0.10×10⁻⁶) = 1 / (2π × 1.0×10⁻²) = 15.92 Hz Selectivity check: f₀/BW ≈ 2250 / 15.92 ≈ 141.4 ≈ Q
  5. Supply and branch currents at resonance (current magnification): Supply current: I_s = V / R_p = 10 / 1.0×10⁵ = 0.000100 A = 0.10 mA Inductor branch current magnitude: |I_L| ≈ V / √(r² + (ω₀L)²) ≈ V/(ω₀L) for high Q Numbers: |I_L| ≈ 10 / (14142 × 0.05) = 10 / 707.1 = 0.01414 A = 14.14 mA Capacitor branch current magnitude: |I_C| = V·ω₀C = 10 × 14142 × 0.10×10⁻⁶ = 0.01414 A Magnification: |I_L| ≈ |I_C| ≈ Q × I_s = 141.4 × 0.10 mA ≈ 14.14 mA (consistent) Final answers: f₀ ≈ 2250 Hz, R_p ≈ 100 kΩ, Q ≈ 141.4, BW ≈ 15.92 Hz, I_s ≈ 0.10 mA, |I_L| ≈ |I_C| ≈ 14.14 mA at resonance.

Example 3 — Theory: Derive BW = R/L for series RLC in rad/s and relate to Q Model answer sketch:

  1. Start with series RLC impedance Z = R + jX, where X = ωL − 1/(ωC).
  2. Current magnitude: |I| = V/√(R² + X²).
  3. At resonance (ω = ω₀), X = 0, so |I_max| = V/R.
  4. Define half-power frequencies ω₁, ω₂ where |I| = |I_max|/√2 = V/(R√2).
  5. Therefore √(R² + X²) = √2·R ⇒ X² = R² ⇒ |X| = R.
  6. Solve ωL − 1/(ωC) = ±R for ω. Multiply by ωC:
    • Upper: LC·ω² − RC·ω − 1 = 0 ⇒ root ω₂.
    • Lower: LC·ω² + RC·ω − 1 = 0 ⇒ root ω₁.
  7. Subtract the two equations or use properties of quadratics to get ω₂ − ω₁ = R/L (the difference of roots of these “mirror” quadratics equals b/a difference). Hence, BW_rad = ω₂ − ω₁ = R/L.
  8. Since ω₀ = 1/√(LC) and Q = ω₀L/R, divide: Q = ω₀/BW_rad.
  9. Convert to hertz: BW = BW_rad/(2π) = R/(2πL). Conclude: For a series RLC, BW_rad = R/L, BW = R/(2πL), and Q = ω₀/BW_rad = f₀/BW.

Common mistakes

  • Using the high-Q approximation f₁,₂ ≈ f₀ ± BW/2 even when Q is low (this gives noticeable error; use exact equations when Q is small).
  • Confusing Q definitions: for series Q = ω₀L/R, for parallel Q = R_p/(ω₀L) = ω₀CR_p (do not substitute R_p into series formula or vice versa).
  • Forgetting that at series resonance, V_L and V_C can be much larger than source V (voltage magnification), but they cancel in phasor sum.
  • Ignoring inductor resistance in a parallel tank; without r, the input impedance tends to infinity at resonance, which is not realistic.
  • Unit errors: H (not henry-seconds), F, Ω; ensure C in farads when evaluating ω₀.

For your exam

  • Derivations: condition for resonance ω₀ = 1/√(LC); series RLC bandwidth BW_rad = R/L; relation Q = ω₀/BW_rad; half-power frequency equations for series RLC; approximate dynamic resistance R_p ≈ L/(C·r) for a high-Q tank (state assumptions).
  • Numericals: compute f₀, Q, BW, f₁ and f₂; voltages across L and C at resonance for given source V; for parallel tanks, compute R_p, Q, BW, and circulating currents.
  • Diagrams: series and parallel resonant circuits with clear labels; phasor diagrams at resonance as described in Key ideas. A full-marks diagram has correct element order, all symbols and units labeled, phasor directions and relative magnitudes correct, and resonance noted.
  • What earns full marks: state assumptions (sinusoidal steady-state, high-Q if used); write the governing formula, show substitution with units, keep intermediate values with adequate precision, and box or highlight final numeric answers with proper SI units.

Quick check

  1. In a series RLC, what is the impedance and power factor at resonance?
  2. Give two equivalent expressions for Q of a series RLC at resonance.
  3. A high-Q parallel RLC has R_p = 50 kΩ and C = 200 nF. Estimate BW (Hz). Answers: 1) Z = R (purely real), power factor = 1. 2) Q = ω₀L/R = 1/(ω₀CR). 3) BW ≈ 1/(2πR_pC) = 1/(2π × 50×10³ × 200×10⁻⁹) ≈ 15.9 Hz.

Finished this topic? Mark it so your progress, study plan and readiness keep up.

Stuck on something here?