Electromagnetic induction
Electromagnetic induction: Faraday’s and Lenz’s laws, motional vs transformer EMF, self and mutual inductance, energy in magnetic fields, with formulas, derivations, and applications to generators and transformers.
Drafted with Aria, reviewed by the AiCanCode.org team · Updated . How we write and check our notes. Spotted an error? Use Give Feedback at the bottom of the page.
Why it matters
Electromagnetic induction is how electrical energy is generated in power stations and how transformers work in the power system. It also explains inductors, relays, sensors, and losses like eddy currents and hysteresis in machines.
Key ideas
- Flux linkage (λ) — The product of the number of turns N in a coil and the flux linking each turn: λ = N·Φ. SI unit: weber-turn (Wb·turn). If flux is non-uniform among turns, λ is the sum of flux through each turn.
- Electromotive force (emf, e) — The voltage induced due to changing magnetic conditions. SI unit: volt (V). It can be an “open-circuit” induced voltage or cause current when a circuit is closed.
Exact statements:
- Faraday’s laws of electromagnetic induction:
- The magnitude of the induced emf in a circuit is directly proportional to the rate of change of flux linkage with the circuit.
- The direction of the induced emf is such that it opposes the change in flux producing it (stated by Lenz’s law). As a formula: e = −dλ/dt = −N·dΦ/dt. In integral form (Maxwell–Faraday law): ∮C E·dl = − d/dt ∫S B·dA. Assumptions: quasistatic conditions (field changes slow enough that radiation effects are negligible), lumped circuit model holds, and the induced electric field is non-conservative around the loop (curl E = −∂B/∂t).
- Lenz’s law — The induced emf and the resulting current, if a closed path exists, act in a direction to oppose the change in magnetic flux that produced them. This is a statement of energy conservation. It explains the negative sign in Faraday’s law.
- Fleming’s right-hand rule — If you hold your right hand with thumb, index finger, and middle finger mutually perpendicular: index finger = direction of magnetic field (B, north to south), thumb = motion of conductor (v), middle finger = induced emf (conventional current) direction.
Types of induced emf:
- Motional emf — Induced when a conductor moves in a magnetic field. For a straight conductor of length l moving with velocity v at angle θ to B: e = B·l·v·sinθ. Assumptions: uniform B across the length, rigid conductor, steady velocity, and conductor moves through field lines.
- Transformer (statically induced) emf — Induced in a stationary coil by a time-varying flux linking the coil: e = −N·dΦ/dt. If Φ varies sinusoidally, the rms induced emf is E = 4.44·f·N·Φmax. Assumptions: uniform flux linking all turns equally, sinusoidal flux for the 4.44 formula.
Coils and inductance:
- Self-inductance (L) — The property by which a change in current in a coil induces emf in the same coil. Definition: L = λ/I = N·Φ/I under linear conditions (Φ ∝ I). SI unit: henry (H). Induced emf: e = −L·(di/dt). Assumptions: linear magnetic circuit for L to be constant; otherwise L can be current-dependent.
- Mutual inductance (M) — The property by which a change in current in one coil induces emf in a nearby coil. Definition: M = N2·Φ12 / I1 = N1·Φ21 / I2 under reciprocity, where Φ12 is the flux linking coil 2 due to current I1 in coil 1. Unit: henry (H). Induced emf in coil 2: e2 = −M·(di1/dt). Assumptions: linear media and fixed geometry ensure reciprocity M12 = M21.
- Coefficient of coupling (k) — A measure of how much flux of one coil links the other: k = M / √(L1·L2), 0 ≤ k ≤ 1. k = 1 means perfect coupling (all flux links both coils); k < 1 means leakage flux exists.
Energy and losses:
- Energy stored in an inductor — W = (1/2)·L·I². This is magnetic field energy. Assumptions: linear inductor (L constant).
- Eddy currents — Circulating currents induced within conducting masses by changing magnetic flux. They cause heating (I²R losses) and can create damping forces. Reduced by laminations, higher resistivity materials, or thin sheets.
- Hysteresis — In ferromagnetic cores, B lags H causing a hysteresis loop; energy is lost per cycle equal to loop area. Reduced by using low-hysteresis materials (e.g., silicon steel), appropriate flux density design. (Detailed B–H derivation is part of “Electromagnetism and magnetic circuits”, but its consequence—loss in induction devices—is noted here.) Here H is magnetic field strength (A/m).
Common derivations universities ask:
- From Faraday’s law to induced emf in a rotating coil (AC generator model):
- Consider a rectangular coil with N turns, area A, rotating at angular speed ω in a uniform B field. If the normal to the coil makes angle θ = ωt with B, the flux is Φ = B·A·cosθ.
- Flux linkage λ = N·Φ = N·B·A·cosθ.
- Induced emf e = −dλ/dt = N·B·A·ω·sinθ. This is a sinusoid with maximum Emax = N·B·A·ω.
- rms value Erms = Emax/√2 for a single frequency sinusoid. Diagram to draw: rectangle coil in uniform field between north–south poles; show axis of rotation, label area A, N turns, B direction, angular velocity ω; indicate θ between coil normal and B. Mark slip rings if mentioning practical generator.
- Sinusoidal transformer emf: starting from e = −N·dΦ/dt with Φ = Φmax·sin(ωt), we get e = −N·ω·Φmax·cos(ωt) = N·ω·Φmax·sin(ωt − 90°). The rms value is Erms = 4.44·f·N·Φmax using ω = 2πf and the form factor for a sine wave. Diagram to draw: simple core with primary turns N, sinusoidal flux Φ in the core, arrows showing linkage to turns; label Φmax and direction of induced e.
- Self and mutual inductance relationships: L = N·Φ/I for linear circuits; M = k·√(L1·L2). Show that the energy in two magnetically coupled coils is W = (1/2)L1I1² + (1/2)L2I2² ± M·I1·I2 (sign depends on dot convention). For this topic, you need the definitions and M relation; the full energy expression may be asked as a short note. Diagram to draw: two coils on a common core with dots marking the similarly oriented terminals; show fluxes Φ11 (self) and Φ12 (mutual) linking coils.
Assumptions commonly expected to be stated:
- Lumped-parameter model: coils have negligible resistance when deriving ideal induced emf relationships (unless resistance is specifically included).
- Linear magnetic material when using constant L and M.
- Uniform flux distribution when using λ = N·Φ.
- Sinusoidal variation when using 4.44·f·N·Φmax.
Applications to mention: AC generators (alternators), transformers (voltage step-up/step-down), inductors and chokes (filters), relays and solenoids (actuation), induction heating (eddy currents), speed sensors (variable reluctance), braking (eddy current brakes), and energy meters.
Formulas
Φ = B·A·cosθ — Magnetic flux through a plane area A at angle θ to B. Φ in Wb, B in T, A in m², θ in radians; applies for uniform B over the area.
λ = N·Φ — Flux linkage. λ in Wb·turn, N is number of turns (dimensionless), Φ in Wb; when all turns link the same flux.
e = −dλ/dt = −N·dΦ/dt — Faraday’s law (instantaneous emf). e in V, λ in Wb·turn, t in s; general induction.
e = B·l·v·sinθ — Motional emf of a straight conductor. e in V, B in T, l in m, v in m/s, θ angle between v and B; uniform B and rigid motion.
e(t) = N·B·A·ω·sin(ωt) — Emf of a coil of area A with N turns rotating at angular speed ω in uniform B; instantaneous value in V; assumes θ = ωt measured from the maximum-flux position (coil normal initially aligned with B).
Emax = N·B·A·ω — Maximum emf for rotating coil. Emax in V; B in T, A in m², ω in rad/s.
Erms = Emax/√2 — Rms of sinusoidal emf; applies to pure sine wave.
Erms = 4.44·f·N·Φmax — Rms transformer emf per winding with sinusoidal core flux. Erms in V, f in Hz, N turns, Φmax in Wb; assumes sinusoidal flux linking all turns.
L = λ/I = N·Φ/I — Self-inductance of a coil. L in H, λ in Wb·turn, I in A; linear magnetic circuit.
e = −L·(di/dt) — Induced emf in an inductor due to its own current change. e in V, L in H, di/dt in A/s.
M = N2·Φ12/I1 = N1·Φ21/I2 — Mutual inductance between two coils. M in H; Φ12 is flux linking coil 2 due to current I1, etc.; linear media, fixed geometry.
e2 = −M·(di1/dt) — Induced emf in coil 2 due to current change in coil 1. e2 in V, M in H, di1/dt in A/s.
k = M/√(L1·L2) — Coefficient of coupling (dimensionless), 0 to 1.
W = (1/2)·L·I² — Energy stored in an inductor. W in J, L in H, I in A; linear inductor.
Peddy ∝ Bmax²·f²·t²·V/ρ — Eddy current loss proportionality in a solid core: increases with square of peak flux density Bmax, frequency f, sheet thickness t, volume V, and inversely with resistivity ρ. Exact constants depend on material and geometry; used qualitatively to justify laminations.
Worked examples
Example 1: Transformer emf from sinusoidal flux Given: A coil has N = 200 turns on a core with sinusoidal flux of peak value Φmax = 5 mWb at frequency f = 50 Hz. Find the rms induced emf.
- Formula: Erms = 4.44·f·N·Φmax
- Substitute with SI units: Φmax = 5 mWb = 0.005 Wb Erms = 4.44 × 50 × 200 × 0.005 V
- Compute: 200 × 0.005 = 1; 4.44 × 50 × 1 = 222 V Answer: The rms induced emf is 222 V.
Example 2: Motional emf in a moving conductor Given: A straight conductor of length l = 0.30 m moves with speed v = 10 m/s in a uniform magnetic field B = 0.8 T. The velocity makes an angle θ = 60° with the field. Find the induced emf and its polarity by Fleming’s right-hand rule.
- Formula: e = B·l·v·sinθ
- Substitute: e = 0.8 T × 0.30 m × 10 m/s × sin 60°
- Compute: 0.30 × 10 = 3; 0.8 × 3 = 2.4; sin 60° ≈ 0.8660; e = 2.4 × 0.8660 ≈ 2.0784 V Answer: The induced emf magnitude is 2.08 V. Polarity: use right-hand rule (index along B, thumb along v, middle finger gives direction of induced current/emf).
Example 3: Inductance, induced voltage, and stored energy Given: An inductor with L = 0.50 H has current rising linearly from 0 A to 10 A in time Δt = 0.20 s. Find (a) the induced emf, and (b) the energy stored at 10 A. (a) Induced emf
- Formula: e = −L·(di/dt)
- di/dt = (10 − 0) A / 0.20 s = 50 A/s
- e = −0.50 H × 50 A/s = −25 V (negative sign means polarity opposes increase in current) (b) Stored energy
- Formula: W = (1/2)·L·I²
- Substitute: W = 0.5 × 0.50 H × (10 A)² = 0.25 × 100 = 25 J Answer: Induced emf is −25 V, and energy stored is 25 J.
Example 4: Mutual inductance from linked flux Given: Two coils share a core. Coil 1 has N1 = 100 turns and carries current I1 = 2.0 A, producing flux Φ11 = 5.0 mWb in the core. Due to coupling, 80% of this flux links coil 2 which has N2 = 200 turns. Find M.
- Flux linking coil 2 due to I1: Φ12 = 0.80 × Φ11 = 0.80 × 0.005 Wb = 0.004 Wb
- Formula: M = N2·Φ12 / I1
- Substitute: M = 200 × 0.004 / 2.0 = 0.8 / 2.0 = 0.40 H Answer: Mutual inductance is 0.40 H.
Common mistakes
- Mixing up motional emf and transformer emf conditions (motion vs time-varying flux in a stationary coil).
- Wrong angle in motional emf: θ is the angle between v and B, not between the conductor and B.
- Not stating assumptions (sinusoidal flux, uniform linkage, linear core), which can lose marks in theory questions.
- Using B instead of Φ in N·dΦ/dt or missing N when calculating coil emf.
- Unit errors: Wb vs mWb, T vs mT, leading to answers off by powers of ten.
For your exam
- Numericals: calculate induced emf (transformer type), motional emf (with angle), energy in inductor, mutual inductance from given data. Full marks: correct formula, substitutions with units, neat calculation, and final answer highlighted.
- Short notes: eddy current losses and reduction methods; hysteresis loss concept; applications of electromagnetic induction in power engineering. Full marks: concise explanation, relation to practice, and methods to reduce losses.
- Diagrams: coil in magnetic field with motion and direction markings; core and windings showing flux paths; two coupled coils with dot convention. Full marks: correct labels (B, Φ, N, A, v, θ, ω), polarity arrows, and neatness.
Quick check
- State Faraday’s laws of electromagnetic induction.
- A 0.25 m conductor moves at 12 m/s perpendicular to a 0.6 T field. Find the induced emf.
- Define mutual inductance and give its SI unit. Answers: (1) Induced emf is proportional to the rate of change of flux linkage, and its direction opposes the change (Lenz’s law); e = −dλ/dt. (2) e = B·l·v = 0.6 × 0.25 × 12 = 1.8 V. (3) Mutual inductance is M = N2·Φ12/I1, the flux linkage in one coil per unit current in another; unit: henry (H).
Finished this topic? Mark it so your progress, study plan and readiness keep up.
Stuck on something here?