Electrical quantities and Ohm's law
Defines charge, current, voltage/EMF, resistance/conductance, resistivity/conductivity, power and energy; states and derives Ohm’s law (macroscopic and microscopic), R = ρ·L/A, and applies them with series/parallel ideas to typical circuits.
Drafted with Aria, reviewed by the AiCanCode.org team · Updated . How we write and check our notes. Spotted an error? Use Give Feedback at the bottom of the page.
Why it matters
Electrical quantities and Ohm’s law are the foundation for every circuit you will study. Whether you size a resistor, select a cable for safe current, estimate power consumption, or interpret instrument readings, you use these definitions, laws and simple models daily.
Key ideas
- Potential difference or voltage (V): Work done per unit charge to move a test charge between two points. Definition: V = W/Q. SI unit: volt (V) = J/C.
- Electromotive force (EMF, ℰ): Energy supplied per unit charge by a source (e.g., a cell) when no current is drawn (open‑circuit). Unit: volt (V). EMF is the source’s ideal voltage.
- Resistance (R): Opposition offered by a conductor to current flow. For ohmic conductors under constant physical conditions, R = V/I. SI unit: ohm (Ω).
- Conductance (G): Ease of current flow. Definition: G = 1/R. SI unit: siemens (S = Ω⁻¹).
- Resistivity (ρ): Material property that quantifies how strongly a material opposes current, independent of shape. SI unit: ohm‑metre (Ω·m). Lower ρ means better conductor.
- Conductivity (σ): Reciprocal of resistivity. Definition: σ = 1/ρ. SI unit: S/m.
- Current density (J): Current per unit cross‑sectional area at a point. Definition: J = I/A_c (if uniform). SI unit: A/m².
- Electric field (E): Force per unit charge; in a conductor carrying steady current, E drives charges. SI unit: V/m.
- Power (P): Rate of electrical energy conversion. P = VI, or P = I²R, or P = V²/R. SI unit: watt (W).
- Energy (W or E_elec): Electrical work done over time, W = P·t = VIt. SI unit: joule (J).
Exact statements and derivations
Exact statement of Ohm’s law (macroscopic form): “Under constant physical conditions (especially constant temperature), the current through a conductor is directly proportional to the potential difference across it.” Mathematically, V ∝ I ⇒ V = I·R, where R is the resistance of the conductor. Assumptions: material is ohmic (linear V–I), temperature and other physical conditions (e.g., strain, illumination for some materials) remain constant, contact resistances negligible, frequency low enough that reactive effects are negligible.
Microscopic (differential) form of Ohm’s law: J = σ·E, or equivalently E = ρ·J. This relates the local current density to the local electric field inside a material. Assumptions: material is homogeneous and isotropic with scalar σ, steady state (no displacement current considerations), linear response region.
Derivation of R = ρ·L/A from microscopic Ohm’s law (common exam derivation):
- Consider a uniform conductor of length L and uniform cross‑sectional area A, carrying steady current I under an applied voltage V.
- Inside the conductor, assume uniform electric field E along length; then V = E·L (because potential drop is line integral of E along length for uniform field).
- Current density J = I/A (uniform distribution assumed).
- From microscopic Ohm’s law: E = ρ·J = ρ·(I/A).
- Substitute into V = E·L: V = (ρ·I/A)·L = I·(ρ·L/A).
- Compare with V = I·R to get R = ρ·L/A. Assumptions: uniform cross‑section, homogeneous isotropic material, steady state, end effects neglected.
Temperature dependence of resistance for metals (linear approximation over a limited range): R_T = R_T0 · [1 + α·(T − T0)], where α is the temperature coefficient of resistance at reference temperature T0 (commonly 20 °C). Valid for a modest temperature range; for large ranges or semiconductors, non‑linear models are required.
Series and parallel resistors (simple applications often paired with Ohm’s law):
- Series: same current flows, voltages add: R_eq(series) = R1 + R2 + …
- Parallel: same voltage across branches, currents add: 1/R_eq(parallel) = 1/R1 + 1/R2 + …; for two in parallel, R_eq = (R1·R2)/(R1 + R2). Assumptions: ideal connections, DC or low frequency so that inductance/capacitance are negligible.
What to draw in an exam (descriptive diagram instructions)
- Ohm’s law verification setup: Draw a DC source (battery or variable DC supply) connected in series with a variable resistor (rheostat), a fixed test resistor R (the device under test), and an ammeter A. Connect a voltmeter V across the test resistor R. Label polarities of the voltmeter, mark current direction, and indicate that readings of V and I are taken for different settings of the rheostat.
- V–I characteristic: Draw axes with V on y‑axis and I on x‑axis. For an ohmic resistor, plot a straight line passing through origin; mark slope as ΔV/ΔI = R; alternatively, slope of I–V plot is 1/R. Label at least three measured points and the best‑fit line.
Formulas
I = dQ/dt — I: current (A); Q: charge (C); t: time (s). Applies always by definition.
Q = I·t — Q: charge (C); I: current (A); t: time (s). For constant current over time t.
V = W/Q — V: voltage (V); W: work or energy (J); Q: charge (C). Definition of potential difference.
V = I·R — V: voltage (V); I: current (A); R: resistance (Ω). Ohm’s law for ohmic conductors at constant physical conditions.
P = V·I — P: power (W); V: voltage (V); I: current (A). Instantaneous electrical power.
P = I²·R — Derived from P = VI and V = IR; for a resistor carrying current I.
P = V²/R — Derived from P = VI and I = V/R; for a resistor with voltage V.
W = P·t = V·I·t — W: energy (J); P: power (W); t: time (s). Energy consumed over time t.
R = ρ·(L/A) — R: resistance (Ω); ρ: resistivity (Ω·m); L: length (m); A: cross‑sectional area (m²). Uniform conductor of homogeneous material.
G = 1/R — G: conductance (S); R: resistance (Ω). Always.
σ = 1/ρ — σ: conductivity (S/m); ρ: resistivity (Ω·m). Always.
J = I/A_c — J: current density (A/m²); I: current (A); A_c: conductor cross‑sectional area (m²). Uniform current distribution.
J = σ·E — J: current density (A/m²); σ: conductivity (S/m); E: electric field (V/m). Microscopic Ohm’s law.
E = ρ·J — E: electric field (V/m); ρ: resistivity (Ω·m); J: current density (A/m²). Equivalent microscopic form.
R_T = R_T0·[1 + α·(T − T0)] — R_T: resistance at temperature T (Ω); R_T0: resistance at reference T0 (Ω); α: temperature coefficient (1/°C); T, T0: temperatures (°C). Linear approximation for modest ranges.
R_eq(series) = R1 + R2 + … — Equivalent resistance in series (Ω). DC, ideal wires.
1/R_eq(parallel) = 1/R1 + 1/R2 + … — Reciprocal of equivalent resistance in parallel (S = Ω⁻¹). DC, ideal wires.
R_eq(two in parallel) = (R1·R2)/(R1 + R2) — Shortcut for two resistors in parallel (Ω).
Worked examples
Example 1: Basic Ohm’s law, power and energy Given: A 3.0 Ω resistor is connected across a 12.0 V DC source for 2.00 minutes.
- Required: current, power dissipated, and energy consumed.
- Formulae: I = V/R; P = V·I; W = P·t.
- Calculations:
- I = V/R = 12.0 V / 3.0 Ω = 4.0 A.
- P = V·I = 12.0 V · 4.0 A = 48.0 W.
- Time t = 2.00 min = 2.00 × 60 s = 120 s.
- W = P·t = 48.0 W · 120 s = 5760 J. Answer: Current = 4.0 A; Power = 48.0 W; Energy = 5760 J (i.e., 5.76 kJ).
Example 2: Designing a heater wire using resistivity Given: Required resistance R = 20.0 Ω using nichrome wire of cross‑sectional area A = 0.50 mm²; resistivity of nichrome ρ = 1.10 × 10⁻⁶ Ω·m. Find the length L of wire. Also, if connected to 230 V, find current and power.
- Formulae: R = ρ·(L/A) ⇒ L = (R·A)/ρ; I = V/R; P = V²/R.
- Unit conversion: A = 0.50 mm² = 0.50 × 10⁻⁶ m².
- Length:
- L = (R·A)/ρ = (20.0 Ω · 0.50 × 10⁻⁶ m²)/(1.10 × 10⁻⁶ Ω·m)
- L = (10.0 × 10⁻⁶ Ω·m²)/(1.10 × 10⁻⁶ Ω·m) = 9.0909… m.
- L ≈ 9.09 m.
- If connected to 230 V:
- I = V/R = 230 V / 20.0 Ω = 11.5 A.
- P = V²/R = (230 V)² / 20.0 Ω = 52900 / 20.0 = 2645 W. Answer: Required wire length ≈ 9.09 m; Current ≈ 11.5 A; Power ≈ 2.645 kW. Assumptions: Temperature rise ignored in R; actual heater will get hotter, increasing R somewhat; safe current density and insulation are design considerations beyond this calculation.
Example 3: Temperature coefficient of resistance and current Given: A copper coil has resistance R_20°C = 10.00 Ω at 20 °C. Take α (at 20 °C) = 0.00393 /°C. Find its resistance at 80 °C and the current when 24.0 V is applied at 80 °C.
- Formulae: R_T = R_T0·[1 + α·(T − T0)]; I = V/R.
- Temperature rise: ΔT = 80 − 20 = 60 °C.
- Resistance at 80 °C:
- R_80 = 10.00 Ω · [1 + 0.00393/°C · 60 °C]
- R_80 = 10.00 Ω · [1 + 0.2358] = 10.00 Ω · 1.2358 = 12.358 Ω.
- Current at 24.0 V:
- I = V/R = 24.0 V / 12.358 Ω ≈ 1.9417 A. Answer: Resistance at 80 °C ≈ 12.36 Ω; Current at 24.0 V ≈ 1.942 A. Notes: Linear α is an approximation; for wider temperature ranges, consult manufacturer data.
Common mistakes
- Misplacing instruments. Ammeter must be in series (low internal resistance); voltmeter must be in parallel (high internal resistance). Wrong placement disturbs the circuit and readings.
- Unit conversion errors. mm² to m² (1 mm² = 1 × 10⁻⁶ m²) and minutes to seconds are common pitfalls.
- Using wrong power formula. Choose P = I²R when current is known, P = V²/R when voltage across the element is known, and P = VI in general. Do not mix supply voltage with branch voltage incorrectly in networks.
- Confusing EMF with terminal voltage. Terminal voltage = EMF − I·r (internal drop). With no load, terminal voltage equals EMF; under load, it is lower.
- Slope confusion on V–I plots. For a V on y‑axis vs I on x‑axis graph, slope = R; for I vs V graph, slope = 1/R.
For your exam
- Derivations: R = ρ·L/A from E = ρJ with V = E·L and J = I/A; relation between P, V, I, and R; linear temperature coefficient formula (state assumptions and valid range).
- Short notes: Ohmic vs non‑ohmic conductors; microscopic vs macroscopic Ohm’s law; effect of temperature on R for metals, alloys, and mention that semiconductors have negative temperature coefficient.
- Diagrams: Ohm’s law verification circuit, correct ammeter/voltmeter connections, labeled V–I characteristics with slope identified.
- Numericals: Compute R, I, V, P, W; design length/area of a conductor from ρ; temperature‑dependent R; simple series/parallel equivalent R applied with V = IR. Show steps, formula before numbers, carry units, and round sensibly with significant figures.
- Presentation tips for full marks: State assumptions; write units for every numerical step; box or underline final answers; draw neat, labeled diagrams as described; for derivations, write each equality clearly and explain substitutions.
Quick check
- A 5 Ω resistor has 2 A through it. What is the voltage across it and the power dissipated?
- A copper wire of length 4 m and cross‑sectional area 1.0 mm² has ρ = 1.68 × 10⁻⁸ Ω·m. Find its resistance.
- State the microscopic form of Ohm’s law and identify each symbol’s SI unit. Answers: (1) V = I·R = 10 V; P = VI = 20 W. (2) R = ρ·L/A = (1.68 × 10⁻⁸ Ω·m · 4 m)/(1.0 × 10⁻⁶ m²) = 0.0672 Ω. (3) J = σ·E, where J in A/m², σ in S/m, E in V/m.
Finished this topic? Mark it so your progress, study plan and readiness keep up.
Stuck on something here?