Multispectral, thermal and hyperspectral sensing
Multispectral, thermal and hyperspectral sensing: how sensors measure wavelength-dependent light and heat, the sensor trade-offs (spectral, spatial, radiometric), key physical laws (Planck, Wien, Stefan–Boltzmann), sensor types and imaging modes, with worked numerical examples and exam-focused notes
Drafted with Aria, reviewed by the AiCanCode.org team · Updated . How we write and check our notes. Spotted an error? Use Give Feedback at the bottom of the page.
Why it matters
Multispectral, thermal and hyperspectral sensing are used by engineers to extract material, temperature and chemical information from objects without contact — in remote sensing, agriculture, surveillance, industrial inspection and medical screening. Understanding spectra, sensor trade-offs and radiometric laws lets you choose the right sensor and interpret images correctly for measurement and automated decision systems.
Key ideas
Start from light as electromagnetic radiation and temperature as a source of emission.
Electromagnetic radiation: oscillating electric and magnetic fields that travel at the speed of light. We treat radiation by its wavelength (λ, in metres) or frequency (ν, in Hz). Use wavelength for optical/infrared sensors.
Spectral radiance: Radiance L(λ) is the power per unit area per unit solid angle per unit wavelength leaving a surface or arriving at a sensor, measured in W·m^-2·sr^-1·m^-1. Radiance is what imaging sensors sample (after optics and detector response).
Reflectance: Reflectance ρ(λ) is the fraction (dimensionless, 0–1) of incident spectral irradiance that a surface reflects at wavelength λ. It is independent of illumination if defined as directional hemispherical reflectance under specified geometry.
Emissivity: Emissivity ε(λ) is the ratio (0–1) of spectral radiance emitted by a real surface to that emitted by a blackbody at the same temperature and wavelength. A blackbody has ε = 1. By Kirchhoff’s law at thermal equilibrium, emissivity equals absorptivity: ε(λ) = α(λ).
Blackbody radiation: described exactly by Planck's law (see Formulas). From Planck we derive Wien's displacement law (peak wavelength vs temperature) and Stefan–Boltzmann law (total emitted power ∝ T^4).
Thermal vs reflected signal: thermal sensors (mid-wave and long-wave infrared) measure emitted radiance related to surface temperature and emissivity; reflected-light sensors (visible, NIR, SWIR) measure reflected radiance that depends on illumination and surface reflectance. Observed radiance is a sum of emitted and reflected components modulated by atmosphere and sensor response.
Multispectral vs hyperspectral:
- Multispectral: imaging in a small number (typically 3–10, sometimes up to ~20) of broad spectral bands separated to capture major features (e.g., RGB, NIR, SWIR bands). Bands are non-contiguous or widely spaced.
- Hyperspectral: imaging with a large number (typically >100) of narrow, contiguous spectral bands across a continuous wavelength range, producing a spectrum for each pixel. Define these precisely in exam answers: number of bands and whether bands are contiguous are the distinguishing criteria.
Sensor spectral ranges (typical definitions): give wavelength bands used in remote sensing and thermal imaging — list these when you need to choose sensors:
- Visible (VIS): ~0.4–0.7 μm
- Near infrared (NIR): ~0.7–1.0 μm
- Short-wave IR (SWIR): ~1.0–3.0 μm
- Mid-wave IR (MWIR): ~3–5 μm
- Long-wave IR (LWIR): ~8–14 μm (common thermal imaging; corresponds to an atmospheric transmission window; likewise MWIR 3–5 μm). State these ranges and specify any differing convention if your exam or datasheet uses different cutoffs.
Sensor types and detectors:
- CCD/CMOS: silicon-based detectors for VIS–NIR (up to ~1.0 μm with reduced sensitivity beyond 0.9 μm).
- InGaAs detectors: sensitive in NIR and SWIR (commonly 0.9–1.7 μm, extended versions to ~2.5 μm).
- MCT/Mercury Cadmium Telluride (HgCdTe): used for MWIR and LWIR; typically requires cooling (cryogenic or TEC) for high sensitivity.
- Microbolometer: uncooled thermal detectors used for LWIR, common in small thermal cameras.
- InSb (Indium Antimonide) detectors: sensitive in MWIR (3–5 μm), typically cooled; widely used in scientific/defense MWIR cameras.
Imaging modes:
- Pushbroom (line-scan): a single line detector records spectra as the platform moves — common in hyperspectral satellite sensors.
- Whiskbroom (scanning mirror): scans across track with a single detector element or small array.
- Snapshot (frame) hyperspectral: captures full spatial and spectral cube in one exposure (requires special optics/filters and trades SNR/spectral resolution).
Resolutions and trade-offs:
- Spatial resolution (GSD): ground/sample size per pixel (m/pixel) — smaller is finer detail.
- Spectral resolution: width of each spectral channel (nm) or number of bands — narrower bands give finer spectral discrimination but lower signal per band.
- Radiometric resolution: number of digital levels (bits) and sensor noise floor — higher radiometric resolution resolves smaller differences in radiance.
- These are traded: higher spectral resolution reduces radiance per band so needs longer integration or lower spatial resolution or better SNR.
Radiometric measurement equation (simplified): for a sensor looking at a surface, Observed radiance L_obs(λ) = τ(λ) [ε(λ)·B(λ,T) + (1-ε(λ))·(E_down(λ)/π)] + L_path(λ) where τ is atmospheric transmittance, B is blackbody spectral radiance, E_down is downwelling irradiance (W·m^-2·m^-1), π converts irradiance to radiance for a Lambertian reflector, and L_path is atmospheric path radiance. Explain each term when deriving temperature from measured radiance.
Noise Equivalent Temperature Difference (NETD): for thermal cameras, NETD (or NEΔT) is the smallest temperature difference the camera can resolve (in K or mK). Lower NETD is better.
Diagrams to draw when required in answers:
- Draw the electromagnetic spectrum horizontal axis labeled wavelength in μm, mark VIS, NIR, SWIR, MWIR, LWIR ranges and typical sensor types beneath each.
- For pushbroom: sketch a satellite path with ground track, indicate line array perpendicular to motion and show how successive lines build a cube (x, y, λ) and label axes.
- For thermal radiometry: draw a surface at temperature T emitting radiation B(λ,T), incident downwelling irradiance, and the sensor with atmosphere between, label ε, τ, L_atm_path.
If you use any numerical constants or specific band edges, say where they came from (datasheet, standard) — conventions vary.
Formulas
Planck spectral radiance: L_λ(T) = (2·h·c^2) / (λ^5 · (exp(h·c / (λ·k_B·T)) - 1)) — L_λ in W·m^-2·sr^-1·m^-1; h = Planck constant (6.62607015e-34 J·s); c = speed of light (2.99792458e8 m·s^-1); k_B = Boltzmann constant (1.380649e-23 J·K^-1); applies to blackbody at temperature T (K) and wavelength λ (m).
Wien's displacement law: λ_peak = b / T — λ_peak in metres, T in kelvin, b ≈ 2.897771955e-3 m·K; gives peak emission wavelength of a blackbody.
Stefan–Boltzmann law: M = ε·σ·T^4 — M is total radiant exitance (power per unit area) in W·m^-2; ε is emissivity (0–1); σ = 5.670374419e-8 W·m^-2·K^-4; applies to total emitted power over all wavelengths for a (gray) surface at temperature T.
Ground sample distance (GSD): GSD = (H · p) / f — GSD in metres per pixel; H = flight/altitude (m) above ground (for nadir imaging), p = pixel pitch (m), f = focal length (m); assumes simple pinhole geometry and nadir view.
Radiometric measurement (simplified): L_obs(λ) = τ(λ) [ε(λ)·B_λ(T) + (1-ε(λ))·(E_down(λ)/π)] + L_path(λ) — L_obs(W·m^-2·sr^-1·m^-1), τ transmittance (0–1), E_down is downwelling irradiance (W·m^-2·m^-1), L_path is atmospheric path radiance.
Spectral resolution (approx): Δλ = spectral_range / number_of_bands — Δλ in same units as spectral_range (e.g., nm); for hyperspectral Δλ is small (narrow bands).
Worked examples
Example 1 — Peak emission of human body (Wien) Problem: Find the peak emission wavelength for a human skin temperature T = 37.0 °C. Steps:
- Convert to kelvin: T = 37.0 + 273.15 = 310.15 K.
- Use Wien's law: λ_peak = b / T, with b = 2.897771955e-3 m·K.
- Compute: λ_peak = 2.897771955e-3 / 310.15 = 9.343e-6 m = 9.343 μm. Answer: λ_peak ≈ 9.34 μm (in the LWIR band). (Explain: thermal cameras for human detection are designed around LWIR where peak emission lies.)
Example 2 — Ground Sample Distance (GSD) Problem: A down-looking camera on a drone has pixel pitch p = 5.0 μm, focal length f = 25.0 mm. The drone flies at H = 100.0 m. What is the GSD in cm/pixel? Steps:
- Convert to SI: p = 5.0e-6 m, f = 25.0e-3 m, H = 100.0 m.
- Use GSD = (H · p) / f.
- Compute: GSD = (100.0 · 5.0e-6) / 25.0e-3 = (5.0e-4) / 25.0e-3 = 0.02 m. Answer: GSD = 0.02 m per pixel = 2.0 cm per pixel. (Discuss: to improve spatial resolution either reduce altitude H, increase focal length f, or use smaller pixel pitch p — but focal length and field-of-view trade off coverage area.)
Example 3 — Simple thermal radiance to temperature (model answer style) Question: A LWIR sensor measures spectral radiance near λ = 10 μm corresponding to a blackbody radiance L_λ = 3.0e6 W·m^-2·sr^-1·m^-1. Using Planck's law, find approximate blackbody temperature T. (Show method; you may solve numerically.) Model answer approach: Rearrange Planck's law numerically for T and solve (iterate or use software). Outline steps: plug λ = 10e-6 m, use Planck formula, solve for T via numerical root-finding. State final numerical T (students should show iteration or tool). For the given values, solving yields T ≈ 240 K (about −33 °C). Note: in exam you may be given simplified constants or allowed to use calculators/computers.
Common mistakes
- Mixing units: μm vs nm vs m. Convert to SI (m) before plugging into Planck/Wien formulas.
- Treating multispectral as simply “few-band hyperspectral” without noting band width and contiguity — exam answers must state both band count and whether bands are contiguous.
- Assuming thermal cameras measure temperature directly; they measure radiance and need calibration, emissivity, and atmospheric correction to get temperature.
- Forgetting sensor spectral response: sensor band nominal range differs from detector sensitivity curve; mention spectral response when required.
For your exam
Question types you will see
- Definitions: define radiance, reflectance, emissivity, multispectral, hyperspectral, NETD, GSD.
- Short notes: compare multispectral vs hyperspectral; sensor types for VIS/NIR/SWIR/MWIR/LWIR; pushbroom vs snapshot.
- Derivations: derive Wien's law from Planck (outline steps by setting the derivative of Planck’s law with respect to λ equal to 0) or show Stefan–Boltzmann by integrating Planck over all wavelengths.
- Numericals: compute λ_peak from Wien, compute GSD, convert measured radiance to blackbody temperature (may require numerical solution), estimate spectral resolution Δλ.
- Diagrams: draw spectral ranges on a wavelength axis; sketch imaging geometries (pushbroom line-scan), label axes and components.
What full-marks answers include
- Precise definitions with symbols and units.
- Stated assumptions (e.g., blackbody or gray body, nadir imaging, no atmospheric scattering) and mention of corrections if assumptions fail.
- Correct formula application with unit conversions shown.
- If derivation required, show calculus steps (e.g., differentiate Planck’s law to get Wien) or clear integration steps (for Stefan–Boltzmann).
Quick check
- Define emissivity and state its range of values.
- Which spectral band (NIR, SWIR, MWIR, LWIR) contains the peak blackbody emission for human skin at 310 K? Use Wien’s law reasoning.
- A camera has pixel pitch 4 μm and focal length 16 mm; at 120 m altitude what is the GSD in cm/pixel? (Use GSD = H·p / f.) Answers: 1) Emissivity is the ratio of spectral radiance of a real surface to that of a blackbody at same T; range 0–1. 2) LWIR (~8–14 μm). 3) p=4e-6 m, f=16e-3 m, H=120 m ⇒ GSD = (120·4e-6)/16e-3 = 0.03 m = 3.0 cm/pixel.