Image sampling and quantisation
Notes on image sampling (spatial/temporal discretisation) and quantisation (amplitude discretisation): definitions, Nyquist sampling theorem for 1D and 2D, aliasing and anti-aliasing, uniform quantisers and error/SNR/PSNR, with worked numerical examples and exam guidance.
Drafted with Aria, reviewed by the AiCanCode.org team · Updated . How we write and check our notes. Spotted an error? Use Give Feedback at the bottom of the page.
Why it matters
Digital images are created and processed by discretising a continuous light field in two ways: by sampling (making a grid of pixels) and by quantisation (assigning each pixel an integer intensity). Engineers design cameras, sensors, and image-processing systems to avoid aliasing, choose sensor resolution, select bit-depth, and evaluate image quality (PSNR, SNR). Good choices reduce visible artifacts and improve downstream tasks such as compression and segmentation.
Key ideas
Band-limited — a signal is band-limited if its Fourier transform is zero for spatial/temporal frequencies above some finite maximum f_max. This is an important assumption in the sampling theorem.
1D Sampling theorem (Nyquist–Shannon, exact statement): Let f(t) be a continuous-time signal with Fourier transform F(ω) = ∫{−∞}^{∞} f(t) e^{−jωt} dt, and suppose F(ω) = 0 for |ω| > ω_m (band-limited to ω_m). Sample f(t) at period T (sampling angular frequency ω_s = 2π/T) to obtain f_s(t) = f(t)·Σ{n=−∞}^{∞} δ(t − nT). Then the Fourier transform of the sampled signal is F_s(ω) = (1/T) · Σ_{k=−∞}^{∞} F(ω − k·ω_s). If ω_s > 2·ω_m (equivalently sampling frequency f_s = 1/T > 2·f_m), the spectral replicas do not overlap and f(t) can be perfectly reconstructed by an ideal low-pass filter that selects the baseband component. Assumption: ideal low-pass filter and exact band-limiting; practical signals are not perfectly band-limited so pre-filtering (anti-aliasing) is used.
Derivation sketch (standard exam derivation):
- Write sampling impulse train p_T(t) = Σ δ(t − nT).
- Sampled signal f_s(t) = f(t) p_T(t).
- Use Fourier transform property: multiplication in time → convolution in frequency. The FT of p_T(t) is (2π/T) Σ δ(ω − k·ω_s) (or with convention-dependent constant; use the convention stated above so you keep the 1/T factor in final formula).
- Convolution of F(ω) with that delta comb produces a periodic sum of shifted copies of F(ω): F_s(ω) = (1/T) Σ F(ω − k·ω_s).
- For perfect reconstruction, the shifted copies must not overlap; hence ω_s > 2ω_m.
What to draw for an exam diagram:
- Draw a 1D frequency axis (ω); draw the baseband spectrum F(ω) as a finite-width block from −ω_m to +ω_m.
- Draw periodic replicas centered at k·ω_s for k = ±1, ±2.
- Label ω_s and ω_m and show the non-overlap condition ω_s > 2ω_m (replicas separated by gap) and the overlap case (aliasing).
Aliasing — when spectral replicas overlap during sampling, high frequencies fold into lower frequencies producing distortions (moiré patterns in images). Prevent by ensuring sampling satisfies Nyquist or by pre-filtering (optical or electronic low-pass) before sampling. In practice, sensors have limited modulation transfer and lenses act as anti-aliasing to some degree.
2D sampling (images): For a separable rectangular (square) sampling grid with sampling intervals Δx and Δy, the 2D spectrum is replicated on a 2D lattice with spacing 1/Δx in fx and 1/Δy in fy. For no aliasing we require the image’s spatial frequency content to be limited so that replicas in both directions do not overlap. A simple sufficient condition: f_xmax < 1/(2Δx) and f_ymax < 1/(2Δy), where f_x, f_y are cycles per unit distance.
Reconstruction — ideal reconstruction of a band-limited sampled signal is by convolution with a sinc (1D) or separable sinc (2D) kernel. In practice we use finite-support interpolators (bilinear, bicubic) and accept approximation.
Uniform quantiser — divides the input amplitude range [X_min, X_max] into equal intervals of width Δ. For a b-bit quantiser, L = 2^b. If both endpoints X_min and X_max are representable output levels (e.g., codes 0..L−1), the quantisation step (LSB) is Δ = (X_max − X_min)/(L − 1). For a mid-rise design whose decision thresholds span [X_min, X_max] while reproduction levels exclude the endpoints, use Δ = (X_max − X_min)/L. The quantiser maps any input in an interval to a representative level. Two common designs: mid-rise and mid-tread (difference affects whether zero maps to a level or midpoint).
Quantisation error e = x − Q(x). For a uniform quantiser and assuming the input is uniformly distributed within each quantisation interval (common exam assumption), the quantisation error is approximately a random variable with zero mean and variance σ_e^2 = Δ^2/12. The maximum absolute error ≤ Δ/2 (worst-case bound).
Signal-to-quantisation-noise ratio (SNR): For a full-scale sinusoidal input and a uniform quantiser with b bits, the theoretical SNR (in dB) is approximately SNR ≈ 6.02·b + 1.76 dB. This follows from computing signal power of a sine and the uniform quantisation noise variance under the uniform-distribution assumption.
MSE and PSNR — For images, Mean Squared Error (MSE) between original and quantised image (or reconstructed image) is MSE = (1/N) Σ (I_orig − I_rec)^2. Peak Signal-to-Noise Ratio (PSNR) is PSNR = 10·log10 (MAX_I^2 / MSE) dB, where MAX_I is the maximum possible pixel value (for 8-bit images MAX_I = 255).
Formulas
L = 2^b — L is number of quantisation levels, b is bits per sample (no units). Applies to uniform quantisers.
Δ = (X_max − X_min) / (L − 1) — Δ is the LSB step when both endpoints are representable (e.g., 0–255). For a mid-rise quantiser whose reproduction levels exclude the endpoints, use Δ = (X_max − X_min) / L.
|e| ≤ Δ/2 — quantisation error bound (same units). Worst-case for mid-rise/mid-tread type quantisers.
σ_e^2 = Δ^2 / 12 — variance of quantisation error under the common assumption that error is uniformly distributed on (−Δ/2, Δ/2) (units: squared signal units). Assumes uniform distribution of error.
f_s ≥ 2·f_max — Nyquist condition (Hz). For continuous-time sampling with highest frequency f_max (Hz). Equality is critical (no margin); usually choose f_s > 2·f_max.
F_s(ω) = (1/T) · Σ_{k=−∞}^{∞} F(ω − k·ω_s) — relation between Fourier transforms of sampled and continuous signals. ω_s = 2π/T (rad/s). Assumes FT defined as F(ω)=∫ f(t)e^{−jωt} dt and impulse-train sampling.
MSE = (1/N) Σ_{i=1..N} (x_i − x̂_i)^2 — mean squared error (units: squared pixel units). Applies to discrete images of N pixels.
PSNR = 10 · log10( MAX_I^2 / MSE ) — PSNR in dB. MAX_I is maximum possible pixel value (unit: same as pixel values).
SNR (dB) ≈ 6.02·b + 1.76 — approximate SNR for a full-scale sinusoidal signal quantised with b bits. Assumes uniform quantiser and full-scale sine input.
Worked examples
- 1D sampling (audio-style numerical) Problem: A continuous signal has highest frequency f_max = 4.0 kHz. Find the minimum sampling frequency f_s (Nyquist) and corresponding sampling period T. Solution:
- Formula:
f_s ≥ 2·f_max. - Compute:
f_s_min = 2 * 4.0 kHz = 8.0 kHz. - Sampling period:
T = 1 / f_s = 1 / 8000 Hz = 0.000125 s = 125 µs. Answer: Minimum sampling frequency is 8.0 kHz, sampling period 125 µs.
- 2D spatial sampling (pixels) Problem: An imaging system must capture spatial frequencies up to 1.2 cycles/mm in both x and y. What is the maximum allowable square pixel pitch Δ (in mm) to avoid aliasing (Nyquist) assuming ideal band-limited image content? Solution:
- Nyquist in x-direction:
f_xmax < 1/(2·Δ)⇒Δ ≤ 1/(2·f_xmax). - Compute:
Δ_max = 1 / (2 * 1.2 cycles/mm) = 1 / 2.4 mm^{-1} = 0.416666... mm ≈ 0.417 mm. Answer: Maximum pixel pitch should be 0.417 mm or smaller to avoid aliasing.
- Quantisation and PSNR (image) Problem: 8-bit uniform quantisation on a greyscale image with range 0–255 (full scale). Assume quantisation behaves like uniform noise with variance Δ^2/12. Compute Δ, quantisation noise variance, and PSNR assuming the MSE equals the quantisation noise variance under this model. Solution:
b = 8⇒L = 2^8 = 256.Δ = (255 − 0) / (256 − 1) = 255/255 = 1.0(greyscale level unit).- Noise variance
σ_e^2 = Δ^2 / 12 = 1^2 / 12 = 0.08333....{ - PSNR:
PSNR = 10 log10( MAX_I^2 / MSE )withMAX_I = 255andMSE ≈ σ_e^2. Compute numerator:255^2 = 65025. Ratio:65025 / (1/12) = 65025 * 12 = 780,300.{PSNR = 10 * log10(780300) ≈ 10 * 5.892 = 58.92 dB.{ Answer: Δ = 1.0, quantisation noise variance = 0.08333, PSNR ≈ 58.9 dB.
(Notes: small differences arise with rounding. The common SNR approximation for a full-scale sine gives ≈ 6.02·8 + 1.76 = 48.16 + 1.76 = 49.92 dB; PSNR differs because it uses peak value whereas SNR here uses sine RMS.)
Common mistakes
- Confusing spatial frequency units (cycles/mm) with pixel frequency (cycles/pixel); always state units.
- Using PSNR and SNR interchangeably without noting definitions (PSNR uses peak value; SNR uses signal power).
- Forgetting that
σ_e^2 = Δ^2/12assumes a uniform distribution of the error; it is not exact for all inputs. - Assuming ideal band-limited images — real images are not perfectly band-limited and need anti-aliasing filters.
For your exam
Types of questions asked:
- Definitions: sampling, quantisation, aliasing, Nyquist rate, band-limited.
- Derivations: prove the sampled-signal FT formula and derive the Nyquist condition (step-by-step derivation expected, draw frequency diagrams).
- Numericals: compute minimum sampling rate/period, pixel pitch from spatial frequency, Δ and PSNR for b-bit quantiser.
- Short notes: advantages/limitations of uniform quantisers, anti-aliasing filters and practical reconstruction filters (sinc vs bilinear).
- Diagrams: draw frequency-domain replicas and label ω_s, ω_m, show aliasing vs non-aliasing.
What a full-marks answer includes:
- Clear definitions (bold the term and define), explicit assumptions (band-limited, FT convention), a correct derivation with each step justified, a labelled diagram when requested, and numerical answers with units and working.
Quick check
- State the Nyquist sampling rate for a signal with highest frequency 10 kHz.
- For a 6-bit uniform quantiser with range 0–63, what is Δ?
- What is the maximum absolute quantisation error for step Δ? Answers: 1) 20 kHz (sampling period 50 µs). 2) L = 2^6 = 64, Δ = (63 − 0)/(64 − 1) = 63/63 = 1.0. 3) Δ/2.
Finished this topic? Mark it so your progress, study plan and readiness keep up.
Stuck on something here?