PAHSU · Second Year B.Tech. Electrical Engineering · NEP 2020
Electrical Transmission and Distribution
EEPCC-04 · Semester IV · 3 credits · ISE 30 + ESE 70
Unit 1: Corona and Sag in Overhead Lines
7 hoursCorona: principle, terms and empirical formulae, factors affecting it, advantages, disadvantages and methods of reducing it; sag in overhead lines and its calculation.
Examined in the 70-mark end-semester paper
- Corona and corona loss
- Sag calculation for overhead lines
- Effect of ice and wind loading
- Sag with supports at unequal levels
Unit 2: Constants of Transmission Lines
7 hoursLine resistance, skin and proximity effects; inductance of a single-phase two-wire line, GMR and GMD; inductance of three-phase lines with equilateral and unsymmetrical spacing and transposition; capacitance of single- and three-phase lines and the effect of earth.
Examined in the 70-mark end-semester paper
- Skin and proximity effects
- Inductance of a single-phase line
- GMR and GMD
- Inductance of three-phase lines and transposition
- Capacitance of a single-phase line
- Capacitance of three-phase lines
- Effect of earth on capacitance
Unit 3: Underground Cables
6 hoursConstruction, insulating materials and classification of cables; insulation resistance, capacitance and dielectric stress of a single-core cable; grading of cables; capacitance of three-phase cables.
Examined in the 70-mark end-semester paper
- Underground cables and dielectric stress
- Grading of cables
- Cables: types, jointing and insulation resistance
Unit 4: Performance of Transmission Lines
8 hoursClassification of lines; performance of short lines and the effect of load power factor on regulation and efficiency; medium lines by the end-condenser, nominal-T and nominal-pi methods; rigorous solution of long lines; generalised ABCD constants; Ferranti effect.
Examined in the 70-mark end-semester paper
- Classification of transmission lines
- Performance of short lines
- Efficiency and regulation of lines
- Nominal-T and nominal-pi models
- Long transmission lines
- ABCD constants
- Ferranti effect
Unit 5: Distribution Systems
6 hoursClassification and connection schemes; DC distributors fed at one and both ends with concentrated loads, and ring mains; AC distribution calculations; three-phase three-wire and four-wire loads.
Examined in the 70-mark end-semester paper
- Classification and requirements of distribution systems
- DC distributors and the three-wire DC system
- AC distribution calculations
- Unbalanced three-phase four-wire loads
Unit 6: Introduction to Extra High Voltage Transmission
6 hoursEHV AC transmission: introduction, advantages and limitations; HVDC transmission: classification, advantages, limitations and applications.
Examined in the 70-mark end-semester paper
- Need for EHV transmission
- HVDC versus EHVAC transmission
- Classification of HVDC links
Unit contents are summarised from the official PAHSU syllabus . AiCanCode.org is not affiliated with Punyashlok Ahilyadevi Holkar Solapur University (PAHSU).