GUG · Third Year B.Tech. Electrical Engineering · NEP 2020
Electrical Machine Design
STPCCELE505 · Semester V · 3 credits · IE 10 + mid-semester 10 + ESE 80
Unit 1: General Aspects of Electrical Machine Design
9 hoursMaterials used in electrical machines; insulating materials classed by permissible temperature rise; properties of transformer oil; ratings and specifications; heating and cooling characteristics.
Examined in the 80-mark end-semester paper, and in the mid-semester exam if it is taught by then
- Electrical engineering materials and space factor
- Insulating materials in power apparatus
- Temperature rise and rating of machines
- Heating and cooling time constants
Unit 2: Transformer Design
9 hoursOutput equations of single- and three-phase transformers; voltage per turn, stepped cores, specific loadings, window space factor and dimensions; main dimensions, core, yoke and winding design.
Examined in the 80-mark end-semester paper, and in the mid-semester exam if it is taught by then
- Transformer construction and specifications
- Output equation of a transformer
- Design of the core and frame
- Design of transformer windings
Unit 3: Operating Characteristics of Transformers
9 hoursWinding resistance and leakage reactance, no-load current, losses and regulation; cooling methods and tank design; mechanical forces on transformers.
Examined in the 80-mark end-semester paper, and in the mid-semester exam if it is taught by then
- Leakage reactance of transformers
- No-load current and losses of transformers
- Cooling and tank design
- Short-circuit forces
Unit 4: Induction Machine
9 hoursOutput equation, specific electric and magnetic loadings, turns per phase and stator slots; main dimensions and stator design; slot shapes and combinations; cage and wound rotor design; performance from design data.
Examined in the 80-mark end-semester paper, and in the mid-semester exam if it is taught by then
- Output equation of an induction motor
- Specific electric and magnetic loadings
- Main dimensions and stator design
- Cage rotor design
- Wound rotor design
Unit 5: Synchronous Machine
9 hoursAir-gap length; obtaining a sinusoidal output voltage; field coil design for salient-pole machines and turbo-generator rotors; ventilation and cooling circuits, hydrogen and water cooling.
Examined in the 80-mark end-semester paper, and in the mid-semester exam if it is taught by then
- Main dimensions of synchronous machines
- Short-circuit ratio and air gap of synchronous machines
- Salient pole machine design
- Field and damper winding design
- Turbo-alternator design
- Methods of cooling and ventilation
Unit contents are summarised from the official GUG syllabus . AiCanCode.org is not affiliated with Gondwana University, Gadchiroli.