DBATU · Third Year B.Tech Electrical Engineering · NEP 2020
Electrical Maintenance and Commissioning of Electrical Equipment
26AF1293VE610 · Semester VI · 2 credits · Continuous assessment 20 + mid-semester 20 + end-semester 60
A vocational and skill course: 2 credits and 2 lectures a week in the structure table (its course page says practical, 1 credit). Units 4 and 5 are printed with 2 hours each.
Unit 1: Maintenance and Condition Monitoring
7 hoursBreakdown, planned and condition-based maintenance; preventive maintenance of transformers, induction motors and alternators; insulation stresses and deterioration, polarisation index and dielectric absorption ratio; condition monitoring and its tools.
Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then
- Maintenance strategies
- Preventive maintenance of transformers and motors
- Insulation deterioration and polarisation index
- Condition monitoring of electrical equipment
Unit 2: Condition Monitoring of Transformers
7 hoursOil testing to IS/IEC standards and reconditioning; transformer failure modes; monitoring bushings and on-load tap changers; dissolved gas analysis and degree of polymerisation.
Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then
- Transformer oil testing and reconditioning
- Condition monitoring of bushings and tap changers
- Dissolved gas analysis
Unit 3: Condition Monitoring of Induction Motors
7 hoursInduction motor parameters; fault diagnosis and monitoring methods; remedies.
Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then
- Induction motor fault diagnosis
- Vibration and motor current signature analysis
Unit 4: Testing of Electrical Equipment
2 hoursCable failures, fault location and remedies; type, routine and special tests on transformers; abnormal conditions, troubleshooting and remedies for transformers and induction motors; testing capacitor banks.
Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then
- Cable fault location
- Type, routine and special tests on transformers
- Troubleshooting induction motors and capacitor banks
Unit 5: Special Tests and Earthing
2 hoursUltrasonic and radiographic tests; megger, heat-run and high-voltage withstand tests; substation earthing: equipment and neutral earthing, maintenance-free earthing, plate and pipe electrodes, step and touch voltages, and testing earth resistance.
Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then
- Ultrasonic and radiographic testing
- Insulation resistance testing
- Heat run and high-voltage withstand tests
- Equipment and neutral earthing
- Step and touch voltages
- Earth resistance testing methods
Unit contents are summarised from the official DBATU syllabus . AiCanCode.org is not affiliated with Dr. Babasaheb Ambedkar Technological University (DBATU).