Instrumentation Engineering
Process Control and Automation
Process dynamics, control valves, PLC, DCS, SCADA, industrial networks.
Your progress in this subject0 of 14 · 0%
- 1Process variables and process dynamicsProcess variables, gain, time constant and dead time, the FOPDT model and how to identify it from a step test.
- 2Self-regulating and non-self-regulating processesSelf-regulating, integrating and runaway processes: models, examples, how to test them and what each means for controller choice.
- 3Controller modes and PID tuning methodsOn-off, P, I and D modes, proportional band, windup and controller action, and Ziegler–Nichols, Cohen–Coon and IMC tuning.
- 4Cascade, ratio, feedforward and split-range controlCascade, ratio, feedforward and split-range schemes: structure, design rules, compensator design and worked numericals.
- 5Control valves: types, characteristics and sizingControl valve types, inherent and installed characteristics, valve authority, Kv/Cv liquid sizing, cavitation and fail-safe action.
- 6Actuators, positioners and I/P convertersI/P converters, spring-diaphragm and other actuators, fail-safe action, positioners and actuator force calculations.
- 7P&ID drawing and ISA instrumentation symbolsReading and drawing P&IDs: ISA-5.1 tags, balloons and locations, signal lines, valve symbols and loop interpretation.
- 8PLC architecture and I/O modulesPLC hardware, digital and analog I/O modules, sinking/sourcing, analog resolution and scaling, and the scan cycle with response-time calculations.
- 9Ladder logic programmingLadder diagram instructions, Boolean equivalence, start–stop seal-in, timers and counters, and scan-order effects with worked examples.
- 10Distributed control systemsDCS architecture from field to plant level, function-block configuration, redundancy and availability, alarm management, and DCS versus PLC and SCADA.
- 11SCADA systemsSCADA components, RTUs, communication media, polling versus report by exception, protocols, cybersecurity and link/polling-time calculations.
- 12Field communication: 4-20 mA, HART, Modbus, Profibus and Fieldbus4–20 mA loops with live zero and power budgets, HART, Modbus, PROFIBUS DP/PA and FOUNDATION Fieldbus compared, with loop calculations.
- 13Safety instrumented systems and SILSafety instrumented systems, layers of protection, SIL bands, LOPA-based SIL targets and PFDavg verification for 1oo1, 1oo2 and 2oo3 designs.
- 14Control of boilers, distillation columns and heat exchangersBoiler drum-level, pressure and combustion control, distillation column configurations, and heat-exchanger temperature control with energy and material balances.