Digital Protection

EE0354 · Programme Elective I · Semester V · 3 credits · ISE 10 + mid-semester 30 + ESE 60

One of the Programme Elective I options.

  1. Unit 1: Fundamentals of Power System Protection

    6 hours

    Need for protection, components of a protection system, zones, primary and backup protection; sensitivity, selectivity, reliability and speed; classification of relays.

    Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then

    • Zones of protection
    • Primary and backup protection
    • Classification of protective relays and automatic reclosing
  2. Unit 2: Conventional and Static Relays

    8 hours

    Attraction and induction electromagnetic relays, the induction disc relay; static relays, their merits and limits; amplitude and phase comparators.

    Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then

    • Induction relay, PSM and TSM
    • Static relays
    • Static relay comparators: amplitude and phase
  3. Unit 3: Digital and Numerical Relays

    6 hours

    Digital protection and the digital relay block diagram; sampling, signal conditioning and filtering, A/D conversion; microprocessor-based and numerical relays.

    Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then

    • Numerical relays
    • Microprocessor-based overcurrent and impedance relays
    • Digital relaying algorithms: Mann-Morrison and Fourier
  4. Unit 4: Protection of Transmission Lines

    6 hours

    Overcurrent and directional protection; impedance, reactance and mho distance relays; carrier current protection.

    Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then

    • Overcurrent and directional relays
    • Distance relays: impedance, reactance and mho
    • Carrier protection and PLCC
  5. Unit 5: Protection of Power System Equipment

    8 hours

    Transformer differential and Buchholz protection; generator, motor and bus-bar protection.

    Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then

    • Transformer differential protection
    • Buchholz relay and inrush
    • Alternator protection
    • Induction motor protection
    • Bus zone and frame leakage protection
  6. Unit 6: Circuit Breakers and Modern Protection

    8 hours

    Arc formation and extinction; oil, air-blast, SF6 and vacuum breakers compared; SCADA-based, adaptive and smart-grid protection.

    Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then

    • Arc formation and interruption
    • Air-break, oil and air-blast circuit breakers
    • SF6 circuit breaker
    • Vacuum circuit breaker
    • Wide area measurement systems