SPPU TE Electrical syllabus

SPPU · Third Year Electrical Engineering · 2024 Pattern

Power System Engineering II

PCC-351-ELE · Semester VI · 4 credits · CCE 30 + end-semester 70

  1. Unit 1: Power Flow in Long Lines

    8 hours

    ABCD constants of long lines; complex power and power flow from generalised constants; characteristic impedance and surge impedance loading.

    Marks: 14 in the end-semester exam · CCE: Unit test (12 marks, Units 1 & 2)

    • ABCD constants of long lines
    • Power flow using generalised constants
    • Surge impedance loading
  2. Unit 2: Per-unit System and Load Flow

    8 hours

    Single-line, impedance and reactance diagrams; per-unit quantities, base selection and change of base; network topology, driving-point and transfer admittances; Z-bus and Y-bus by the bus incidence matrix; power-flow equations; bus types; Newton–Raphson load flow for a three-bus system.

    Marks: 14 in the end-semester exam · CCE: Unit test (12 marks, Units 1 & 2)

    • Single-line and reactance diagrams
    • Per-unit system and change of base
    • Formation of the Y-bus matrix
    • Load flow equations and bus classification
    • Newton-Raphson load flow
  3. Unit 3: Symmetrical Faults

    7 hours

    Three-phase short circuit of an unloaded alternator; subtransient, transient and steady-state currents and reactances; fault current without pre-fault current; choosing circuit breakers and current-limiting reactors.

    Marks: 14 in the end-semester exam · CCE: Assignments or case study (12 marks, Units 3 & 4)

    • Short circuit of an unloaded alternator
    • Subtransient and transient reactances
    • Symmetrical fault calculation and short-circuit MVA
    • Current-limiting reactors
  4. Unit 4: Unsymmetrical Faults

    9 hours

    Symmetrical components and power in terms of them; sequence impedances of lines and zero-sequence networks of transformers; L–G, L–L and L–L–G faults on unloaded alternators and simple systems, with and without fault impedance.

    Marks: 14 in the end-semester exam · CCE: Assignments or case study (12 marks, Units 3 & 4)

    • Symmetrical components
    • Sequence impedances and sequence networks
    • Single line-to-ground fault
    • Line-to-line fault
    • Double line-to-ground fault
  5. Unit 5: Reactive Power Compensation and FACTS

    8 hours

    Need for reactive power compensation; production and absorption of reactive power; series and shunt compensation; FACTS devices: TCSC and STATCOM, circuits, working, V–I characteristics and applications.

    Marks: 14 in the end-semester exam · CCE: Seminar, open-book test or quiz (6 marks, Unit 5)

    • Reactive power compensation
    • Series and shunt compensation
    • FACTS devices
    • TCSC and STATCOM

Unit contents are summarised from the official SPPU syllabus . AiCanCode.org is not affiliated with Savitribai Phule Pune University.