SPPU TE Electrical syllabus

SPPU · Third Year Electrical Engineering · 2024 Pattern

Electrical Machines II

PCC-301-ELE · Semester V · 3 credits · CCE 30 + end-semester 70

  1. Unit 1: Three-phase Synchronous Machines

    8 hours

    Construction, rotating-field and rotating-armature types, salient and non-salient poles; excitation; EMF equation and winding factors; armature reaction at different power factors; synchronous reactance, equivalent circuit and phasor diagram; power-angle relation; Blondel's two-reaction theory, Xd and Xq by the slip test.

    Marks: 14 in the end-semester exam · CCE: Unit test (12 marks, Units 1 & 2)

    • Construction of synchronous machines
    • EMF equation and winding factors
    • Armature reaction
    • Synchronous reactance and phasor diagram
    • Power-angle relation
    • Two-reaction theory and the slip test
  2. Unit 2: Voltage Regulation and Parallel Operation

    8 hours

    Regulation by direct loading; open- and short-circuit tests; EMF, MMF and Potier methods; short-circuit ratio; parallel operation of alternators and load sharing; synchronising by lamps and synchroscope; synchronising current, power and torque.

    Marks: 14 in the end-semester exam · CCE: Unit test (12 marks, Units 1 & 2)

    • Open-circuit and short-circuit tests
    • EMF and MMF methods of regulation
    • Potier triangle method
    • Short-circuit ratio
    • Parallel operation of alternators
    • Synchronising an alternator
  3. Unit 3: Three-phase Synchronous Motors

    8 hours

    Principle of operation and starting; equivalent circuit and torque angle; losses, efficiency and power flow; V and inverted-V curves; hunting and its remedies; applications; comparison with induction motors.

    Marks: 14 in the end-semester exam · CCE: Assignments or case study (12 marks, Units 3 & 4)

    • Starting of synchronous motors
    • Torque angle and equivalent circuit
    • V curves and inverted V curves
    • Hunting
    • Synchronous versus induction motors
  4. Unit 4: Induction Motor Control, Induction Generators and Special Motors

    8 hours

    Stator- and rotor-side speed control of induction motors; induction generators; DC series motors on AC and compensated AC series motors; energy-efficient motors; BLDC, stepper (permanent-magnet and variable-reluctance) and permanent-magnet motors.

    Marks: 14 in the end-semester exam · CCE: Assignments or case study (12 marks, Units 3 & 4)

    • Speed control of induction motors
    • Induction generators
    • AC series motors
    • Energy-efficient induction motors
    • BLDC motors
    • Stepper motors
  5. Unit 5: Single-phase Induction Motors

    8 hours

    Construction and double-revolving-field theory; equivalent circuit and torque–slip characteristics; tests for the parameters and performance; self-starting methods; split-phase, capacitor-start, capacitor-start capacitor-run and permanent-capacitor motors.

    Marks: 14 in the end-semester exam · CCE: Seminar, open-book test or quiz (6 marks, Unit 5)

    • Double revolving field theory
    • Equivalent circuit of a single-phase induction motor
    • Tests on single-phase induction motors
    • Starting methods and types of single-phase motors

Unit contents are summarised from the official SPPU syllabus . AiCanCode.org is not affiliated with Savitribai Phule Pune University.