SPPU TE Civil syllabus

SPPU · Third Year Civil Engineering · 2024 Pattern

Structural Audit and Retrofitting of Structures

PEC-361B-CVL · Elective II · Semester VI · 3 credits · CCE 30 + end-semester 70

One of the Elective II options.

All notes for this subject
  1. Unit 1: Causes of Structural Damage

    9 hours

    Mechanical, chemical, seismic and fire damage; corrosion of steel and of RC by carbonation, chlorides and leaching; why audits and retrofitting are needed; repair versus retrofitting.

    Marks: 14 in the end-semester exam · CCE: Unit test (12 marks, Units 1 & 2)

    • Causes of damage to structures
    • Corrosion in RC and steel structures
    • Repair versus retrofitting
  2. Unit 2: Structural Audit

    9 hours

    Assessing structural health; drawings, visual survey and nature of distress; investigation tools, NDT and concrete endoscopy; managing, evaluating and reporting an investigation; roles of client, architect, consultant and contractor.

    Marks: 14 in the end-semester exam · CCE: Unit test (12 marks, Units 1 & 2)

    • Structural audit procedure
    • NDT for distressed structures
    • Audit reports and responsibilities
  3. Unit 3: Structural Health Monitoring

    9 hours

    Local and global, short- and long-term, active and passive, remote and wireless SHM; instrumentation, acquisition and processing; AI in SHM.

    Marks: 14 in the end-semester exam · CCE: Assignments or case study (12 marks, Units 3 & 4)

    • Structural health monitoring techniques
    • SHM instrumentation and data
    • AI in structural health monitoring
  4. Unit 4: Retrofitting Methods

    9 hours

    Moisture barriers, mass reduction, jacketing, shotcrete, ferrocement, new members and base isolation; suitability for RC, steel, masonry and heritage structures.

    Marks: 14 in the end-semester exam · CCE: Assignments or case study (12 marks, Units 3 & 4)

    • Jacketing and shotcrete
    • Ferrocement and adding new members
    • Base isolation
    • Retrofitting masonry and heritage structures
  5. Unit 5: FRP Retrofitting of Columns and Beams

    9 hours

    FRP types and properties, plates, wraps and bars; code provisions; confining RC columns with FRP to ACI 440; flexural and shear strengthening of RC beams.

    Marks: 14 in the end-semester exam · CCE: Seminar, open-book test or quiz (6 marks, Unit 5)

    • Fibre-reinforced polymers
    • FRP confinement of columns
    • FRP strengthening of beams

Unit contents are summarised from the official SPPU syllabus . AiCanCode.org is not affiliated with Savitribai Phule Pune University.