SPPU · Second Year Electrical Engineering · 2024 Pattern (Revised)
Power System Engineering I
PCC-203-ELE · Semester III · 3 credits · CCE 40 + end-semester 60
Unit 1: Power System Basics and Tariffs
6 hoursStructure of a power system; connected load, maximum demand, demand, load, diversity, plant capacity and plant use factors, reserve capacity; load and load-duration curves; base and peak load stations; interconnected grids; tariff principles, two- and three-part, power-factor and TOD tariffs, ABT and kVAh tariffs.
Marks: 12 in the end-semester exam · CCE: Unit test (15 marks, Units 1 & 2)
- Structure of a power system
- Load curves and load factors
- Base load and peak load stations
- Tariff principles
- Two-part and three-part tariffs
- Power factor, TOD and kVAh tariffs
Unit 2: Cables, Overhead Line Mechanics and Insulators
6 hoursConstruction and classification of cables, dielectric stress in single-core cables and grading; overhead line components, sag with equal and unequal supports, ice and wind loading; pin, post, suspension, strain and shackle insulators; string efficiency and how to improve it.
Marks: 12 in the end-semester exam · CCE: Unit test (15 marks, Units 1 & 2)
- Underground cables and dielectric stress
- Grading of cables
- Sag calculation for overhead lines
- Effect of ice and wind loading
- Types of overhead line insulators
- String efficiency
Unit 3: Resistance and Inductance of Lines
6 hoursLine resistance, skin and proximity effects; internal and external flux linkages; inductance of a single-phase line; GMR and GMD; transposition; three-phase lines with symmetrical and unsymmetrical spacing; bundled conductors.
Marks: 12 in the end-semester exam · CCE: Assignments or case study (15 marks, Units 3 & 4)
- Skin and proximity effects
- Inductance of a single-phase line
- GMR and GMD
- Inductance of three-phase lines and transposition
- Bundled conductors
Unit 4: Capacitance of Lines
6 hoursPotential of a charged conductor and of conductors in a group; capacitance of a single-phase line with and without the earth's effect; GMR and GMD for capacitance; transposition; three-phase lines with symmetrical and unsymmetrical spacing; double-circuit lines.
Marks: 12 in the end-semester exam · CCE: Assignments or case study (15 marks, Units 3 & 4)
- Potential due to charged conductors
- Capacitance of a single-phase line
- Effect of earth on capacitance
- Capacitance of three-phase lines
- Double-circuit lines
Unit 5: Performance of Transmission Lines
6 hoursShort, medium and long lines; short-line performance and phasor diagrams; nominal-π and nominal-T models; Ferranti effect; lines as two-port networks and ABCD constants; efficiency and regulation of short and medium lines.
Marks: 12 in the end-semester exam · CCE: Seminar, open-book test or quiz (10 marks, Unit 5)
- Classification of transmission lines
- Performance of short lines
- Nominal-T and nominal-pi models
- ABCD constants
- Ferranti effect
- Efficiency and regulation of lines
Unit contents are summarised from the official SPPU syllabus . AiCanCode.org is not affiliated with Savitribai Phule Pune University.