SPPU BE E&TC syllabus

SPPU · Final Year Electronics & Telecommunication Engineering · 2019 Course

Biomedical Signal Processing

404191A · Elective V · Semester VIII · 3 credits · In-semester 30 + end-semester 70

One of the Elective V options.

  1. Unit 1: Introduction to Biomedical Signals

    7 hours

    Ion transport and transmembrane potential; membrane resistance, capacitance and equivalent circuit; action potential and its propagation; electrodes and data acquisition.

    Marks: 15 in the in-semester exam

    • Transmembrane potential
    • Cell membrane equivalent circuit
    • Action potential
    • Biomedical electrodes
  2. Unit 2: Cardiological Signal Processing

    7 hours

    The heart and cardiac excitation; origin, electrodes and modelling of the ECG; heart rate; arrhythmias, fibrillation, infarction, blocks and WPW; time, frequency and wavelet analysis of the ECG.

    Marks: 15 in the in-semester exam

    • Origin and leads of the ECG
    • Heart rate and ECG periodicity
    • Cardiac arrhythmias in the ECG
    • ECG feature extraction
  3. Unit 3: Neurological Signal Processing

    7 hours

    Brain functions; EEG spectrum and significance; auditory, somatosensory, visual and event-related potentials; epilepsy, sleep disorders and tumours; EEG noise and analysis.

    Marks: 17–18 in the end-semester exam

    • EEG rhythms
    • Evoked potentials
    • EEG in epilepsy and sleep disorders
    • EEG feature extraction
  4. Unit 4: Electromyogram

    7 hours

    Motor units and contraction; EMG and neuromuscular disease; EMG noise; time, frequency and wavelet analysis.

    Marks: 17–18 in the end-semester exam

    • Motor units and EMG
    • EMG in neuromuscular disease
    • EMG feature extraction
  5. Unit 5: Other Biomedical Signals

    6 hours

    Blood pressure and flow; electro-oculogram; respiratory signals; magnetoencephalogram.

    Marks: 17–18 in the end-semester exam

    • Blood pressure and blood flow signals
    • EOG, respiratory signals and MEG
  6. Unit 6: Interference and Noise Cancellation

    6 hours

    Noise in biosignals; IIR, FIR and notch filters; Wiener and adaptive filters; LMS and steepest descent; cancelling 50 Hz in the ECG.

    Marks: 17–18 in the end-semester exam

    • Digital filters for biosignals
    • Wiener filter
    • LMS adaptive filtering
    • Power-line interference cancellation in ECG

Unit contents are summarised from the official SPPU syllabus . AiCanCode.org is not affiliated with Savitribai Phule Pune University.