SPPU BE Electrical syllabus

SPPU · Final Year Electrical Engineering · 2019 Course

Switchgear and Protection

403148 · Semester VIII · 4 credits · In-semester 30 + end-semester 70

  1. Unit 1: Fundamentals of Protective Relaying

    8 hours

    Faults and their effects; relay classification; zones, primary and backup protection; qualities of relaying; trip circuits; overcurrent, directional, differential and distance principles; induction relays, torque equation, PSM, TSM and operating time.

    Marks: 15 in the in-semester exam

    • Zones of protection
    • Primary and backup protection
    • Overcurrent and directional relays
    • Induction relay, PSM and TSM
  2. Unit 2: Arc Interruption

    7 hours

    Arc formation and deionisation; high- and low-resistance interruption; arc theories; recovery and restriking voltage and RRRV; current chopping; capacitive currents; resistance switching.

    Marks: 15 in the in-semester exam

    • Arc formation and interruption
    • Restriking voltage and RRRV
    • Current chopping
    • Resistance switching
  3. Unit 3: Circuit Breakers

    8 hours

    Breaker ratings: breaking, making, short-time and operating sequence; ACB, SF6 and vacuum breakers; auto-reclosing; breaker testing; gas-insulated substations.

    Marks: 17–18 in the end-semester exam

    • Circuit breaker ratings
    • SF6 circuit breaker
    • Vacuum circuit breaker
    • Gas insulated substations
  4. Unit 4: Static and Digital Relaying

    6 hours

    Static relays; numerical relays; sampling and anti-aliasing; phasor measurement units.

    Marks: 17–18 in the end-semester exam

    • Static relays
    • Numerical relays
    • Phasor measurement units
  5. Unit 5: Equipment Protection

    8 hours

    Transformer differential, restricted earth fault, Buchholz, overfluxing and inrush protection; induction motor single-phasing, overload and short-circuit protection; alternator stator and rotor faults and loss of excitation.

    Marks: 17–18 in the end-semester exam

    • Transformer differential protection
    • Buchholz relay and inrush
    • Induction motor protection
    • Alternator protection
  6. Unit 6: Transmission Line Protection

    8 hours

    Feeder overcurrent protection; impedance, reactance, mho and quadrilateral relays; three-zone distance protection; arc resistance and power swing; numerical distance algorithms; PLCC; wide-area measurement.

    Marks: 17–18 in the end-semester exam

    • Distance relays: impedance, reactance and mho
    • Three-zone distance protection
    • Carrier protection and PLCC
    • Wide area measurement systems