SPPU · Final Year Electrical Engineering · 2019 Course
Switchgear and Protection
403148 · Semester VIII · 4 credits · In-semester 30 + end-semester 70
Unit 1: Fundamentals of Protective Relaying
8 hoursFaults and their effects; relay classification; zones, primary and backup protection; qualities of relaying; trip circuits; overcurrent, directional, differential and distance principles; induction relays, torque equation, PSM, TSM and operating time.
Marks: 15 in the in-semester exam
- Zones of protection
- Primary and backup protection
- Overcurrent and directional relays
- Induction relay, PSM and TSM
Unit 2: Arc Interruption
7 hoursArc formation and deionisation; high- and low-resistance interruption; arc theories; recovery and restriking voltage and RRRV; current chopping; capacitive currents; resistance switching.
Marks: 15 in the in-semester exam
- Arc formation and interruption
- Restriking voltage and RRRV
- Current chopping
- Resistance switching
Unit 3: Circuit Breakers
8 hoursBreaker ratings: breaking, making, short-time and operating sequence; ACB, SF6 and vacuum breakers; auto-reclosing; breaker testing; gas-insulated substations.
Marks: 17–18 in the end-semester exam
- Circuit breaker ratings
- SF6 circuit breaker
- Vacuum circuit breaker
- Gas insulated substations
Unit 4: Static and Digital Relaying
6 hoursStatic relays; numerical relays; sampling and anti-aliasing; phasor measurement units.
Marks: 17–18 in the end-semester exam
- Static relays
- Numerical relays
- Phasor measurement units
Unit 5: Equipment Protection
8 hoursTransformer differential, restricted earth fault, Buchholz, overfluxing and inrush protection; induction motor single-phasing, overload and short-circuit protection; alternator stator and rotor faults and loss of excitation.
Marks: 17–18 in the end-semester exam
- Transformer differential protection
- Buchholz relay and inrush
- Induction motor protection
- Alternator protection
Unit 6: Transmission Line Protection
8 hoursFeeder overcurrent protection; impedance, reactance, mho and quadrilateral relays; three-zone distance protection; arc resistance and power swing; numerical distance algorithms; PLCC; wide-area measurement.
Marks: 17–18 in the end-semester exam
- Distance relays: impedance, reactance and mho
- Three-zone distance protection
- Carrier protection and PLCC
- Wide area measurement systems
Unit contents are summarised from the official SPPU syllabus . AiCanCode.org is not affiliated with Savitribai Phule Pune University.