SPPU · Final Year Electrical Engineering · 2019 Course
Power Quality Management
403143B · Elective I · Semester VII · 4 credits · In-semester 30 + end-semester 70
One of the Elective I options.
Unit 1: Basics of Power Quality
7 hoursIEEE 1159 terms: transients, short- and long-duration variations, interruptions, fluctuations, imbalance and flicker; symptoms of poor quality; grounding practices and their effect on power quality.
Marks: 15 in the in-semester exam
- Power quality terms as per IEEE 1159
- Grounding and power quality
Unit 2: RMS Variations, Flicker and Transients
7 hoursVoltage regulation and its devices; reactive power management; causes and effects of flicker; ferroresonance; flicker meters; impulsive and switching transients; surge impedance; transient control.
Marks: 15 in the in-semester exam
- Voltage regulation devices
- Voltage flicker
- Ferroresonance
- Transient overvoltages and their control
Unit 3: Voltage Sag, Swell and Interruption
7 hoursCauses, cost and characteristics of sags; effect of fault type and location; phase-angle jumps; sag types; equipment sensitivity and the CBEMA, ITIC and SEMI F47 curves; measuring sags; sag indices; mitigation by UPS, DVR, SMES and CVT.
Marks: 17–18 in the end-semester exam
- Voltage sags and interruptions
- Voltage sag characteristics and types
- CBEMA and ITIC curves
- Voltage sag mitigation
Unit 4: Harmonics I
7 hoursHarmonics, inter- and sub-harmonics; causes and effects; Fourier analysis; harmonic indices; power under distortion; triplen harmonics; harmonics from lighting, SMPS, transformers, machines, drives and arc furnaces.
Marks: 17–18 in the end-semester exam
- Harmonic indices and THD
- Power under non-sinusoidal conditions
- Triplen harmonics
- Sources of harmonics
Unit 5: Harmonics II
7 hoursSeries and parallel resonance; controlling harmonics; K-rated transformers; harmonic studies and tools; passive, tuned and active filters; IEEE 519-2014 and IEEE 1531.
Marks: 17–18 in the end-semester exam
- Harmonic resonance
- K-rated transformers
- Passive and active harmonic filters
- IEEE 519 harmonic limits
Unit 6: Power Quality Monitoring
7 hoursMonitoring objectives and site surveys; PQ analysers to EN 50160; choosing monitors, locations and transducers; harmonic, transient, event and flicker monitoring; PQ indices and standards.
Marks: 17–18 in the end-semester exam
- Power quality monitoring
- Power quality analysers and EN 50160
- Power quality indices
Unit contents are summarised from the official SPPU syllabus . AiCanCode.org is not affiliated with Savitribai Phule Pune University.