SPPU BE Electrical syllabus

SPPU · Final Year Electrical Engineering · 2019 Course

High Voltage Engineering

403143C · Elective I · Semester VII · 4 credits · In-semester 30 + end-semester 70

One of the Elective I options.

All notes for this subject
  1. Unit 1: Breakdown in Gases

    7 hours

    Ionisation; Townsend's theory and breakdown criterion; streamer mechanism; Paschen's law; corona in point-plane gaps; time lag; numericals.

    Marks: 15 in the in-semester exam

    • Townsend's theory of breakdown
    • Streamer theory
    • Paschen's law
    • Corona discharge
  2. Unit 2: Breakdown in Liquid and Solid Dielectrics

    7 hours

    Suspended particle, cavitation, thermal and stressed-oil theories for liquids; intrinsic, electromechanical, thermal, treeing, tracking and electrochemical breakdown in solids; partial discharge; composite dielectrics.

    Marks: 15 in the in-semester exam

    • Breakdown in liquid dielectrics
    • Breakdown in solid dielectrics
    • Treeing and tracking
    • Partial discharge
  3. Unit 3: Lightning and Switching Overvoltages

    7 hours

    Lightning strokes and charge separation theories; causes and effects of overvoltages; switching surges and their control; statistical insulation coordination.

    Marks: 17–18 in the end-semester exam

    • Lightning phenomenon
    • Switching surges
    • Insulation coordination
  4. Unit 4: Generation of High Voltages and Currents

    7 hours

    Cascaded transformers, resonant circuits and Tesla coils; impulse waveshapes; multistage Marx generators and their triggering; impulse current generation.

    Marks: 17–18 in the end-semester exam

    • Generation of high AC voltages
    • Impulse voltage waveshape
    • Marx impulse generator
    • Impulse current generation
  5. Unit 5: Measurement of High Voltages and Currents

    7 hours

    Sphere gaps; electrostatic, generating and peak voltmeters; resistive, capacitive and mixed dividers; CVTs; CRO for impulses; dielectric loss and partial discharge measurement; high-current measurement; radio interference.

    Marks: 17–18 in the end-semester exam

    • Sphere gap measurement
    • Potential dividers
    • Measurement of impulse voltages
    • Dielectric loss and partial discharge measurement
  6. Unit 6: High Voltage Testing and Laboratories

    7 hours

    Testing insulators, bushings, capacitors, cables and surge arresters; layout, earthing and shielding of HV laboratories.

    Marks: 17–18 in the end-semester exam

    • Testing of insulators and bushings
    • Testing of cables and surge arresters
    • High voltage laboratory layout