RTMNU · Third Year B.Tech Mechanical Engineering · NEP 2020
Refrigeration & Air-conditioning
BME6T21A · Elective II · Semester VI · 3 credits · College 30 + university 70
One of the Elective II options.
Unit 1: Vapour Compression and Air Refrigeration
8 hoursThe vapour compression cycle and the effect of superheating and subcooling; refrigerants, the Montreal and Kyoto protocols, eco-friendly and secondary refrigerants; compressors, evaporators, condensers and expansion devices and cycling controls; air-cycle refrigeration with bootstrap, regenerative and reduced-ambient cycles.
Examined in the 70-mark end-semester paper
- Vapour compression cycle
- Effect of operating conditions on the VCC
- Refrigerants: designation, ODP and GWP
- Secondary refrigerants, zeotropes and azeotropes
- Refrigerant compressors
- Condensers
- Evaporators
- Expansion devices
- Bootstrap and regenerative air refrigeration
Unit 2: Absorption, Other and Compound Systems
8 hoursAqua-ammonia and lithium bromide absorption systems, steam-jet and thermoelectric refrigeration and the vortex tube; compound refrigeration, multiple-compressor and multiple-evaporator systems.
Examined in the 70-mark end-semester paper
- Vapour absorption refrigeration
- Lithium bromide–water absorption system
- Steam-jet, thermoelectric and vortex-tube refrigeration
- Multistage compression with flash intercooling
- Multi-evaporator systems
Unit 3: Psychrometry and Load Calculation
8 hoursPsychrometric properties and processes, classes of air-conditioning systems, thermal comfort, and cooling and heating loads — solar gain, gain through the building structure, design conditions and load calculation methods.
Examined in the 70-mark end-semester paper
- Psychrometric properties of air
- Psychrometric processes and the chart
- Thermal comfort and indoor air quality
- Cooling load estimation
- Inside and outside design conditions
- Sol-air temperature and CLTD
Unit 4: Air Distribution and AC Systems
8 hoursRoom air distribution, grilles and diffusers, filters, losses in ducts, duct design and the friction chart, clean rooms and fans; unitary and central all-air, all-water and air–water systems, VRF, chilled ceilings and beams, displacement ventilation, two-stage evaporative cooling and desiccant dehumidification.
Examined in the 70-mark end-semester paper
- Air distribution and fans
- Duct design and pressure losses
- Duct design methods
- Room air diffusion and filtration
- Clean rooms and radiant cooling
- VRF and VAV systems
- Evaporative cooling and thermal storage
- Desiccant air conditioning
Unit 5: Air-Conditioning System Design
8 hoursDesigning and selecting systems for commercial buildings, supermarkets, hospitals and restaurants; sensing and actuating elements, motors and controls, part-load control, and inverter and double-inverter air conditioners.
Examined in the 70-mark end-semester paper
- Air-conditioning system design for buildings
- Refrigeration controls and safety devices
- Air-conditioning controls, part-load operation and inverters
Unit contents are summarised from the official RTMNU syllabus . AiCanCode.org is not affiliated with Rashtrasant Tukadoji Maharaj Nagpur University (RTMNU).