RTMNU · Final Year B.Tech Electrical Engineering · CBCS
Power Quality
BTCHEE803T · Professional Elective VII · Semester VIII · 3 credits · College 30 + university 70
One of the Professional Elective VII options. Its syllabus page prints no teaching or examination block; the scheme gives it college assessment 30 + university exam 70 like the other electives.
Unit 1: Introduction
8 hoursPower quality terms per IEEE 1159 — transients, voltage variations, interruptions, fluctuations, imbalance and flicker — symptoms of poor power quality, and grounding problems and good practice.
Examined in the 70-mark end-semester paper
- Power quality terms as per IEEE 1159
- Causes and effects of power quality disturbances
- Grounding and power quality
- Wiring and grounding problems and solutions
Unit 2: Flicker and Transient Voltages
6 hoursRMS voltage variations and regulation, voltage regulation devices and reactive power, causes and reduction of flicker, and impulsive and switching transient overvoltages.
Examined in the 70-mark end-semester paper
- Voltage regulation devices
- Voltage flicker
- Transient overvoltages and their control
- Capacitor-switching transients
Unit 3: Voltage Sags, Swells and Interruptions
6 hoursSags and interruptions, their economic impact, causes and characteristics, sag assessment, fault location and level, areas of vulnerability, equipment sensitivity, and mitigation by UPS, DVR, SMES and CVT.
Examined in the 70-mark end-semester paper
- Voltage sags and interruptions
- Voltage sag characteristics and types
- CBEMA and ITIC curves
- Voltage sag mitigation
Unit 4: Waveform Distortion
8 hoursHarmonics, interharmonics and subharmonics, voltage and current distortion, harmonic indices, non-sinusoidal quantities, resonance, K-rated transformers, harmonic analysis tools and filters, and IEEE 519.
Examined in the 70-mark end-semester paper
- Sources of harmonics
- Interharmonics
- Harmonic indices and THD
- Power under non-sinusoidal conditions
- Harmonic resonance
- K-rated transformers
- Passive and active harmonic filters
- IEEE 519 harmonic limits
Unit 5: Power Quality Monitoring
8 hoursMonitoring objectives, site surveys, instruments and monitor selection, monitoring location, period and thresholds, data analysis, harmonic, transient and flicker monitoring, and power quality indices and standards.
Examined in the 70-mark end-semester paper
- Power quality monitoring
- Power quality analysers and EN 50160
- Power quality indices