Power System Analysis
EEPCC-08 · Semester V · 4 credits · ISE 30 + ESE 70
Unit 1: Representation of Power System Components
8 hoursPower in single- and three-phase circuits and complex power balance; equivalent circuits of synchronous machines, lines, transformers and loads; single-line, reactance and per-unit impedance diagrams; network matrices: Y-bus by inspection and singular transformation and the modified bus impedance matrix; AI in power system analysis.
Examined in the 70-mark end-semester paper
- Single-line and reactance diagrams
- Per-unit system and change of base
- Primitive network and incidence matrices
- Formation of the Y-bus matrix
- Z-bus matrix
Unit 2: Symmetrical Faults Analysis
5 hoursSymmetrical faults, percentage reactance and short-circuit kVA; reactors to limit short-circuit current; selecting circuit breaker ratings; transients on a transmission line; short-circuit currents and the reactances of synchronous machines with and without load.
Examined in the 70-mark end-semester paper
- Short circuit of an unloaded alternator
- Subtransient and transient reactances
- Symmetrical fault calculation and short-circuit MVA
- Current-limiting reactors
- Selection of circuit breakers
Unit 3: Symmetrical Components
8 hoursResolving unbalanced phasors into symmetrical components; power in terms of symmetrical components; balanced and unbalanced loads on an unbalanced supply; sequence impedances and networks of alternators, transformers and lines.
Examined in the 70-mark end-semester paper
- Symmetrical components
- Sequence impedances and sequence networks
Unit 4: Unsymmetrical Faults
7 hoursL-G, L-L and L-L-G faults on an unloaded alternator and on a power system, with and without fault impedance; open-conductor faults.
Examined in the 70-mark end-semester paper
- Single line-to-ground fault
- Line-to-line fault
- Double line-to-ground fault
- Open conductor faults
Unit 5: Load Flow Studies
8 hoursComplex power flow and the power flow equations; bus classification, operating constraints and data; Gauss-Seidel method for PQ and PV buses and acceleration of convergence; Newton-Raphson in polar coordinates; fast decoupled load flow; comparison of methods.
Examined in the 70-mark end-semester paper
- Load flow equations and bus classification
- Gauss-Seidel load flow
- Newton-Raphson load flow
- Decoupled and fast decoupled load flow
Unit 6: Stability Studies
6 hoursRotor dynamics and the swing equation; steady-state and transient stability; the equal area criterion and its applications; critical clearing angle and time.
Examined in the 70-mark end-semester paper
- Swing equation
- Steady state, transient and dynamic stability
- Equal area criterion
- Critical clearing angle