Extra High Voltage AC Transmission

EEPEC-03B · Programme Elective III · Semester VI · 4 credits · ISE 30 + ESE 70

One of the Programme Elective III options.

  1. Unit 1: Introduction and Calculation of Line and Ground Parameters

    8 hours

    Engineering aspects and growth of EHV AC and line trends; conductor resistance and temperature rise of bundled conductors; inductance and capacitance, sequence parameters and modes of propagation; resistance and inductance of ground return.

    Examined in the 70-mark end-semester paper

    • Need for EHV transmission
    • Bundled conductors
    • Inductance of EHV lines
    • Capacitance of EHV lines
  2. Unit 2: Voltage Gradient of Conductors and Losses

    7 hours

    Electrostatics and the sphere-gap field; charge-potential relations for multi-conductor lines; surface voltage gradients on conductors and bundle sub-conductors; I2R and corona loss and corona loss formulae; charge-voltage diagram with corona; attenuation of travelling waves by corona; audible noise, corona pulses and radio interference limits.

    Examined in the 70-mark end-semester paper

    • Charge-potential relations
    • Surface voltage gradient on conductors
    • Corona loss
    • Audible noise
    • Radio interference from corona
  3. Unit 3: Theory of Travelling Waves and Standing Waves

    7 hours

    Waves at power frequency and the general solution; standing waves and natural frequencies; open-ended line response to double-exponential and sinusoidal excitation; energising a line with trapped charge; reflection and refraction of travelling waves.

    Examined in the 70-mark end-semester paper

    • Travelling waves on lines
    • Reflection and transmission coefficients
  4. Unit 4: Overvoltages in EHV Systems Caused by Switching Operations

    8 hours

    Types of overvoltage; recovery voltage and circuit breakers; ferro-resonance overvoltages; calculating switching surges with single-phase equivalents; reducing switching surges on EHV systems.

    Examined in the 70-mark end-semester paper

    • Overvoltages from switching transients
    • Ferroresonance
    • Switching surges
  5. Unit 5: Power Frequency Voltage Control and Overvoltages

    7 hours

    Generalised constants and charging currents; the power circle diagram and its use; voltage control by synchronous condensers; sub-synchronous resonance in series-compensated lines; static reactive compensation; AI techniques for power-frequency voltage control.

    Examined in the 70-mark end-semester paper

    • Power flow using generalised constants
    • Power circle diagram and voltage control of EHV lines
    • Synchronous condensers and static VAR systems
  6. Unit 6: Design of EHV AC Lines

    6 hours

    Design factors under steady state; design examples on steady-state limits; line insulation design for transient overvoltages.

    Examined in the 70-mark end-semester paper

    • Design of EHV lines
    • Insulation design for EHV lines
    • Power handling capacity of EHV AC lines