PAHSU · Second Year B.Tech. Electrical Engineering · NEP 2020
DC Machines and Transformer
EEPCC-03 · Semester III · 4 credits · ISE 30 + ESE 70
Unit 1: DC Generators
8 hoursConstruction, principle and EMF equation; armature windings; types of generators and voltage build-up in a shunt generator; armature reaction, demagnetising and cross-magnetising MMFs and remedies; commutation.
Examined in the 70-mark end-semester paper
- Construction and EMF equation of DC generators
- Lap and wave armature windings
- Types of DC machines by excitation
- Open-circuit characteristic of a DC generator
- Armature reaction and commutation
Unit 2: DC Motors
8 hoursPrinciple, back EMF and torque equation; types, losses, efficiency and the condition for maximum efficiency; characteristics and selection for applications; 3-point and 4-point starters; speed control of shunt and series motors.
Examined in the 70-mark end-semester paper
- Back EMF and torque equation of DC motors
- Losses and efficiency of DC machines
- Characteristics of DC shunt and series motors
- DC motor starters
- Speed control of DC motors
Unit 3: Testing of DC Machines
4 hoursDirect and indirect testing: brake test, Swinburne's test and Hopkinson's test.
Examined in the 70-mark end-semester paper
- Brake test on a DC motor
- Swinburne's and Hopkinson's tests
Unit 4: Special Purpose Machines
4 hoursConstruction, working principle, types, characteristics and applications of BLDC and stepper motors.
Examined in the 70-mark end-semester paper
- Brushless DC and stepper motors
- Types of stepper motors
- Stepper motor characteristics
Unit 5: Single Phase Transformer
8 hoursConstruction and types, EMF equation, voltage ratio and kVA rating; no-load and on-load operation with phasor diagrams; losses, efficiency and the condition for maximum efficiency; equivalent circuits and effect of load power factor; polarity, open-circuit and short-circuit tests; parallel operation; the autotransformer.
Examined in the 70-mark end-semester paper
- Ideal transformer
- Phasor diagrams of a transformer
- Equivalent circuit of a transformer
- Efficiency and all-day efficiency
- Voltage regulation of a transformer
- Polarity test
- Open-circuit and short-circuit tests on transformers
- Parallel operation and load sharing
- Autotransformers
Unit 6: Three Phase Transformers
8 hoursConstructional features; star/star, delta/delta, star/delta, delta/star and zigzag connections and terminal labelling; vector groups and choice of connection; magnetising inrush; three-winding transformers; open delta and the Scott connection; on-load and off-load tap changing.
Examined in the 70-mark end-semester paper
- Three-phase transformer connections
- Vector groups
- Buchholz relay and inrush
- Three-winding transformers
- Scott and V-V connections
- On-load tap changers
Unit contents are summarised from the official PAHSU syllabus . AiCanCode.org is not affiliated with Punyashlok Ahilyadevi Holkar Solapur University (PAHSU).