Switchgear & Protection

EEPCC-14 · Semester VII · 3 credits · ISE 30 + ESE 70

  1. Unit 1: Protective Relays

    5 hours

    Need for and desirable qualities of protective relaying; zones, primary and backup protection; attracted-armature, balanced-beam and moving-coil relays; induction disc and cup relays and torque production; static relays.

    Examined in the 70-mark end-semester paper

    • Summation transformers and desirable qualities of relaying
    • Zones of protection
    • Primary and backup protection
    • Induction relay, PSM and TSM
    • Static relays
  2. Unit 2: Overcurrent Protection and Differential Protection

    6 hours

    Rewirable and HRC fuses, their characteristics, application and selection; plug setting and time setting multiplier; radial feeder and ring main protection and relay coordination; earth fault, phase fault and directional relays; static and microprocessor-based overcurrent relays.

    Examined in the 70-mark end-semester paper

    • HRC fuses: characteristics, selection and discrimination
    • Overcurrent and directional relays
    • Protection of parallel feeders and ring mains
    • Earth fault and phase fault protection
    • Microprocessor-based overcurrent and impedance relays
  3. Unit 3: Distance Protection

    5 hours

    Impedance, reactance and admittance characteristics; relay settings for three-zone protection; carrier-aided schemes; electromagnetic, static and microprocessor-based impedance, reactance and mho relays for line protection.

    Examined in the 70-mark end-semester paper

    • Distance relays: impedance, reactance and mho
    • Three-zone distance protection
    • Carrier protection and PLCC
  4. Unit 4: Equipment Protection

    6 hours

    Transformer faults, overcurrent and percentage differential protection, Buchholz relay and over-fluxing protection; generator stator earth and phase faults, unbalance, rotor overheating and earth fault, loss of excitation, motoring and generator-transformer units; induction motor protection; differential protection of busbars.

    Examined in the 70-mark end-semester paper

    • Transformer differential protection
    • Buchholz relay and inrush
    • Alternator protection
    • Induction motor protection
    • Bus zone and frame leakage protection
  5. Unit 5: Circuit Breakers

    5 hours

    Arc voltage-current characteristics; DC and AC arc interruption, high-resistance and current-zero interruption; transient restriking voltage, recovery voltage and RRRV; resistance switching, current chopping and capacitive current interruption.

    Examined in the 70-mark end-semester paper

    • Arc formation and interruption
    • Restriking voltage and RRRV
    • Resistance switching
    • Current chopping
    • Interruption of capacitive current
  6. Unit 6: Types of Circuit Breakers

    5 hours

    Classification; bulk-oil and minimum-oil, air-break and air-blast, SF6 and vacuum breakers; MCB and MCCB; HVDC breakers; ratings and testing of breakers; isolators.

    Examined in the 70-mark end-semester paper

    • Air-break, oil and air-blast circuit breakers
    • SF6 circuit breaker
    • Vacuum circuit breaker
    • HVDC circuit breakers and DC current interruption
    • Circuit breaker ratings
    • Testing of circuit breakers and transformers