KBCNMU · Second Year B.E. Electrical Engineering · NEP 2020
Electrical Machines-I
EE-303 · Semester III · 3 credits · ISE 40 + ESE 60
Unit III also includes the field test on DC series motors.
Unit 1: DC Generator
9 hoursConstruction of the DC machine, EMF induced in an armature coil, lap and wave windings; excitation and classification of DC generators, voltage build-up, critical field resistance and critical speed; armature reaction, commutation and generator characteristics.
Examined in the 60-mark end-semester paper
- Construction and EMF equation of DC generators
- Lap and wave armature windings
- Types of DC machines by excitation
- Open-circuit characteristic of a DC generator
- Armature reaction and commutation
Unit 2: DC Motor
9 hoursPrinciple and working, back EMF, classification and torque equation of DC motors; speed-armature current and speed-torque characteristics; power stages, losses and efficiency; the permanent-magnet DC motor.
Examined in the 60-mark end-semester paper
- Back EMF and torque equation of DC motors
- Characteristics of DC shunt and series motors
- Losses and efficiency of DC machines
- PMDC and DC servo motors
Unit 3: DC Motor Control and Testing
9 hoursModern starters, speed control methods, reversal of rotation and electric braking; direct load test, Swinburne's and Hopkinson's tests and the field test on DC series motors.
Examined in the 60-mark end-semester paper
- DC motor starters
- Speed control of DC motors
- Braking of DC motors
- Brake test on a DC motor
- Swinburne's and Hopkinson's tests
Unit 4: Single-Phase Transformer
9 hoursConstruction and principle, phasor diagram and equivalent circuit; voltage regulation, losses, efficiency and the condition for maximum efficiency; effect of frequency; open-circuit and short-circuit tests.
Examined in the 60-mark end-semester paper
- Ideal transformer
- Phasor diagrams of a transformer
- Equivalent circuit of a transformer
- Voltage regulation of a transformer
- Efficiency and all-day efficiency
- Open-circuit and short-circuit tests on transformers
Unit 5: Three-Phase Transformer
9 hoursConstruction, types of connection and their features, vector groups; parallel operation; harmonics in the magnetising current; tap changers; the Scott connection; all-day efficiency of distribution transformers.
Examined in the 60-mark end-semester paper
- Three-phase transformer connections
- Vector groups
- Parallel operation and load sharing
- Harmonics and the oscillating neutral
- On-load tap changers
- Scott and V-V connections
Unit contents are summarised from the official KBCNMU syllabus . AiCanCode.org is not affiliated with Kavayitri Bahinabai Chaudhari North Maharashtra University (KBCNMU).