GUG TY Electrical syllabus

GUG · Third Year B.Tech. Electrical Engineering · NEP 2020

Power System-II

STPCCELE604 · Semester VI · 3 credits · IE 10 + mid-semester 10 + ESE 80

  1. Unit 1: Power Flow Analysis

    9 hours

    The bus admittance matrix; real and reactive power balance at a node; load and generator specifications; Gauss-Seidel and Newton-Raphson solutions of the power flow equations; computational issues in large systems.

    Examined in the 80-mark end-semester paper, and in the mid-semester exam if it is taught by then

    • Formation of the Y-bus matrix
    • Load flow equations and bus classification
    • Gauss-Seidel load flow
    • Newton-Raphson load flow
    • Decoupled and fast decoupled load flow
  2. Unit 2: Stability Constraints in Synchronous Grids

    9 hours

    The swing equation of a machine on an infinite bus; the power-angle curve; loss of synchronism after a three-phase fault; numerical integration (Euler, Runge-Kutta) and the equal area criterion; effect of rescheduling and series compensation on stability.

    Examined in the 80-mark end-semester paper, and in the mid-semester exam if it is taught by then

    • Swing equation
    • Power angle curve
    • Equal area criterion
    • Step-by-step solution of the swing equation
    • Methods to improve stability
  3. Unit 3: Control of Frequency and Voltage

    9 hours

    Turbines and speed governors, frequency dependence of loads, droop control and power sharing; automatic generation control; reactive power of system components; excitation control and AVRs; shunt compensators, SVCs and STATCOMs; tap-changing transformers; power flow control with DC links and phase shifters.

    Examined in the 80-mark end-semester paper, and in the mid-semester exam if it is taught by then

    • Speed governing and turbine models
    • Automatic generation control
    • Excitation systems and their types
    • Automatic voltage regulator
    • Reactive power compensation
    • TCSC and STATCOM
    • Tap-changing transformers and ULTC control
  4. Unit 4: Monitoring and Control

    9 hours

    Energy control centre functions and SCADA; PMUs and wide-area measurement; state estimation; security assessment and the normal, alert, emergency and extremis states; contingency analysis; preventive and emergency control.

    Examined in the 80-mark end-semester paper, and in the mid-semester exam if it is taught by then

    • Load dispatch centres
    • Phasor measurement units
    • Wide area measurement systems
    • Power system state estimation
    • Power system security and contingency analysis
    • Preventive and emergency control
  5. Unit 5: Power System Economics and Management

    9 hours

    Generator cost curves, utility functions, power exchanges and spot pricing; vertically integrated, purchasing-agency, wholesale and retail market models; demand-side management; transmission and distribution charges; ancillary services; the regulatory framework.

    Examined in the 80-mark end-semester paper, and in the mid-semester exam if it is taught by then

    • Deregulation and electricity markets
    • Restructuring models
    • Power exchanges and day-ahead markets
    • Spot and forward electricity markets
    • Demand side management
    • Transmission pricing methods

Unit contents are summarised from the official GUG syllabus . AiCanCode.org is not affiliated with Gondwana University, Gadchiroli.