GUG · Third Year B.Tech. Electrical Engineering · NEP 2020
Power System-I
STPCCELE504 · Semester V · 3 credits · IE 10 + mid-semester 10 + ESE 80
Unit III is printed twice in the syllabus.
Unit 1: Basic Concepts
9 hoursEvolution and structure of power systems, bulk grids and microgrids; conventional and renewable generation, distributed energy resources and storage; transmission and distribution line diagrams, voltage levels and topologies; synchronous grids and DC interconnections; three-phase circuits, power transfer and reactive power.
Examined in the 80-mark end-semester paper, and in the mid-semester exam if it is taught by then
- Structure of a power system
- Microgrid architecture
- Distributed generation and IEEE 1547
- Need for energy storage
- Choice of transmission voltage
- Real and reactive power in three-phase circuits
Unit 2: System Components
9 hoursOverhead lines and cables: fields around conductors, corona, line and cable parameters, inductance and capacitance; travelling-wave equations; short, medium and long lines, power transfer, voltage profile and reactive power; surge impedance loading; series and shunt compensation. Transformers: three-phase connections and phase shifts, three-winding and autotransformers, neutral-grounding transformers, tap changing and per-phase equivalents.
Examined in the 80-mark end-semester paper, and in the mid-semester exam if it is taught by then
- Corona and corona loss
- Inductance of three-phase lines and transposition
- Capacitance of three-phase lines
- Underground cables and dielectric stress
- Performance of short lines
- Nominal-T and nominal-pi models
- Long transmission lines
- Surge impedance loading
- Series and shunt compensation
- Three-phase transformer connections
- On-load tap changers
Unit 3: Voltages and Insulation Requirements
9 hoursLightning and switching overvoltages and protection against them; insulation coordination; propagation of surges and the voltages they produce; Bewley lattice diagrams.
Examined in the 80-mark end-semester paper, and in the mid-semester exam if it is taught by then
- Travelling waves and switching and lightning surges
- Insulation coordination and overvoltage protection
- Bewley's lattice diagram
Unit 4: Fault Analysis and Protection Systems
9 hoursSymmetrical components; balanced and unbalanced faults; sequence networks of generators, lines and transformers; fault currents; neutral grounding. Switchgear: types of circuit breakers; protection attributes and back-up; overcurrent, directional, distance and differential protection.
Examined in the 80-mark end-semester paper, and in the mid-semester exam if it is taught by then
- Symmetrical components
- Sequence impedances and sequence networks
- Single line-to-ground fault
- Line-to-line fault
- Double line-to-ground fault
- Neutral grounding: solid, resistance and reactance
- Air-break, oil and air-blast circuit breakers
- Primary and backup protection
- Overcurrent and directional relays
- Distance relays: impedance, reactance and mho
- Percentage differential relays
Unit 5: Introduction to DC Transmission and Renewable Energy Systems
9 hoursLCC and VSC DC links and real power control; AC versus DC transmission. Solar PV I-V and P-V characteristics and the power-electronic grid interface; wind turbine power curves, fixed- and variable-speed turbines, PMSG and induction generators and their grid interfaces.
Examined in the 80-mark end-semester paper, and in the mid-semester exam if it is taught by then
- Graetz bridge and HVDC power flow
- VSC HVDC
- HVDC versus EHVAC transmission
- Grid-connected solar PV
- Wind turbine characteristics
- Grid-connected wind systems
Unit contents are summarised from the official GUG syllabus . AiCanCode.org is not affiliated with Gondwana University, Gadchiroli.