Unit 1: Introduction and Survey
7 hoursCauses and importance of transients; RL transients with sine-wave excitation; double-frequency transients; RLC transients by transforms; types of power-system transients, their effects and role in planning.
Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then
- Causes and importance of transients
- RL circuit transients with sinusoidal excitation
- Double frequency transients
- Types of power system transients and their effects
Unit 2: Switching Transients
7 hoursSwitching overvoltages; resistance and load switching and their equivalent circuits; normal and abnormal switching; current suppression and chopping; capacitance switching with single and multiple restrikes; ferroresonance.
Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then
- Overvoltages from switching transients
- Resistance and load switching
- Current suppression and current chopping
- Capacitance switching and restrikes
- Ferroresonance
Unit 3: Lightning Transients
7 hoursCloud and charge formation; the lightning discharge and stroke characteristics; a stroke model; good line design, ground wires and tower-footing resistance; lightning–system interaction.
Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then
- Charge formation in thunderclouds
- Mechanism and characteristics of lightning strokes
- Lightning stroke model
- Ground wires and tower footing resistance
Unit 4: Travelling Waves and Computation of Transients
7 hoursTransient response with lumped and distributed parameters; the travelling-wave concept and step response; Bewley's lattice diagram; standing waves and natural frequencies; reflection and refraction.
Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then
- Transients with lumped and distributed parameters
- Travelling waves on transmission lines
- Bewley's lattice diagram
- Reflection and refraction of travelling waves
- Standing waves and natural frequencies
Unit 5: Transients in Integrated Power Systems
7 hoursShort-line and kilometric faults; voltage distribution in a system; line dropping and load rejection; transients on closing and reclosing; fault-induced overvoltages and switching surges; EMTP for transient computation.
Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then
- Short-line and kilometric faults
- Line dropping and load rejection
- Overvoltages on closing and reclosing lines
- Fault-induced overvoltages and switching surges
- EMTP for transient computation