  1. Unit 1: Power System Protection; Relay Construction and Principles

    7 hours

    Need for protection; nature, causes, types and effects of faults; zones, primary and backup protection; qualities of relaying; classification of relays; auto-reclosing; CTs and VTs for protection; electromechanical, static and numerical relays compared.

    Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then

    • Nature, causes and effects of faults
    • Zones of protection
    • Primary and backup protection
    • Classification of protective relays and automatic reclosing
    • CTs and VTs for protection
    • Static relays
    • Numerical relays
  2. Unit 2: Circuit Breakers

    6 hours

    Fault clearing time; arc voltage and interruption; restriking and recovery voltage; current chopping; capacitive current interruption; air-break, oil, air-blast, SF6, vacuum and HVDC breakers; ratings and testing.

    Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then

    • Arc formation and interruption
    • Restriking voltage and RRRV
    • Current chopping
    • Interruption of capacitive current
    • Air-break, oil and air-blast circuit breakers
    • SF6 circuit breaker
    • Vacuum circuit breaker
    • Circuit breaker ratings
  3. Unit 3: Overcurrent Protection

    7 hours

    Time–current characteristics, current and time settings; directional relays; protection of parallel feeders and ring mains; earth-fault and phase-fault schemes; static and numerical overcurrent relays; microprocessor-based overcurrent, impedance, directional and reactance relays.

    Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then

    • Overcurrent and directional relays
    • Induction relay, PSM and TSM
    • Protection of parallel feeders and ring mains
    • Earth fault and phase fault protection
    • Microprocessor-based overcurrent and impedance relays
    • Distance relays: impedance, reactance and mho
  4. Unit 4: Pilot Relaying; Differential, Machine, Transformer and Bus Protection

    6 hours

    Wire-pilot and carrier-current protection; simple, percentage and balanced-voltage differential protection; generator protection; transformer, bus-zone and frame-leakage protection.

    Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then

    • Wire pilot protection
    • Carrier protection and PLCC
    • Percentage differential relays
    • Alternator protection
    • Transformer differential protection
    • Bus zone and frame leakage protection
  5. Unit 5: Fuses and Protection against Overvoltages

    6 hours

    Fuse characteristics, types, HRC fuses, selection and discrimination; causes of overvoltages; lightning and its wave shape; protecting lines and substations from direct strokes and travelling waves; insulation coordination and BIL.

    Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then

    • HRC fuses: characteristics, selection and discrimination
    • Causes of overvoltages and lightning
    • Protection of lines and substations against lightning
    • Protection against travelling waves
    • Insulation coordination and BIL