DBATU TY Electrical syllabus

DBATU · Third Year B.Tech Electrical Engineering · NEP 2020

Power System Analysis

26AF1293PC501 · Semester V · 3 credits · Continuous assessment 20 + mid-semester 20 + end-semester 60

  1. Unit 1: Modelling of Power Systems

    7 hours

    Complex power flow; single-line and reactance diagrams; the per-unit system for transformers, synchronous machines and loads; graph theory for the primitive network, incidence matrices, and the Y-bus and Z-bus.

    Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then

    • Single-line and reactance diagrams
    • Per-unit system and change of base
    • Primitive network and incidence matrices
    • Formation of the Y-bus matrix
    • Z-bus matrix
  2. Unit 2: Load Flow Studies

    7 hours

    Network model; Y-bus by singular transformation; the load flow problem; Gauss–Seidel, Newton–Raphson, decoupled and fast decoupled load flow; automatic generation control.

    Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then

    • Load flow equations and bus classification
    • Gauss-Seidel load flow
    • Newton-Raphson load flow
    • Decoupled and fast decoupled load flow
    • Automatic generation control
  3. Unit 3: Symmetrical Fault Analysis

    6 hours

    Transients on a line; short circuit of a synchronous machine on no load and on load; short-circuit current computation; selection of circuit breakers; Z-bus formulation and the short-circuit algorithm.

    Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then

    • Short circuit of an unloaded alternator
    • Subtransient and transient reactances
    • Symmetrical fault calculation and short-circuit MVA
    • Selection of circuit breakers
    • Short-circuit studies using the Z-bus
  4. Unit 4: Symmetrical Components and Unsymmetrical Faults

    7 hours

    Symmetrical components; sequence impedances and networks of loads, lines, machines and transformers; L–G, L–L and L–L–G faults with the bus impedance matrix; bus voltages and line currents during faults; open-conductor faults.

    Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then

    • Symmetrical components
    • Sequence impedances and sequence networks
    • Single line-to-ground fault
    • Line-to-line fault
    • Double line-to-ground fault
    • Open conductor faults
  5. Unit 5: Security Analysis

    7 hours

    Security analysis and load dispatch centres; contingency analysis; preventive and emergency control; power quality: causes, effects and mitigation.

    Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then

    • Power system security and contingency analysis
    • Load dispatch centres
    • Preventive and emergency control
    • Power quality: causes, effects and mitigation

Unit contents are summarised from the official DBATU syllabus . AiCanCode.org is not affiliated with Dr. Babasaheb Ambedkar Technological University (DBATU).