DBATU · Third Year B.Tech Electrical Engineering · NEP 2020
Power System Analysis
26AF1293PC501 · Semester V · 3 credits · Continuous assessment 20 + mid-semester 20 + end-semester 60
Unit 1: Modelling of Power Systems
7 hoursComplex power flow; single-line and reactance diagrams; the per-unit system for transformers, synchronous machines and loads; graph theory for the primitive network, incidence matrices, and the Y-bus and Z-bus.
Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then
- Single-line and reactance diagrams
- Per-unit system and change of base
- Primitive network and incidence matrices
- Formation of the Y-bus matrix
- Z-bus matrix
Unit 2: Load Flow Studies
7 hoursNetwork model; Y-bus by singular transformation; the load flow problem; Gauss–Seidel, Newton–Raphson, decoupled and fast decoupled load flow; automatic generation control.
Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then
- Load flow equations and bus classification
- Gauss-Seidel load flow
- Newton-Raphson load flow
- Decoupled and fast decoupled load flow
- Automatic generation control
Unit 3: Symmetrical Fault Analysis
6 hoursTransients on a line; short circuit of a synchronous machine on no load and on load; short-circuit current computation; selection of circuit breakers; Z-bus formulation and the short-circuit algorithm.
Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then
- Short circuit of an unloaded alternator
- Subtransient and transient reactances
- Symmetrical fault calculation and short-circuit MVA
- Selection of circuit breakers
- Short-circuit studies using the Z-bus
Unit 4: Symmetrical Components and Unsymmetrical Faults
7 hoursSymmetrical components; sequence impedances and networks of loads, lines, machines and transformers; L–G, L–L and L–L–G faults with the bus impedance matrix; bus voltages and line currents during faults; open-conductor faults.
Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then
- Symmetrical components
- Sequence impedances and sequence networks
- Single line-to-ground fault
- Line-to-line fault
- Double line-to-ground fault
- Open conductor faults
Unit 5: Security Analysis
7 hoursSecurity analysis and load dispatch centres; contingency analysis; preventive and emergency control; power quality: causes, effects and mitigation.
Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then
- Power system security and contingency analysis
- Load dispatch centres
- Preventive and emergency control
- Power quality: causes, effects and mitigation
Unit contents are summarised from the official DBATU syllabus . AiCanCode.org is not affiliated with Dr. Babasaheb Ambedkar Technological University (DBATU).