DBATU TY Electrical syllabus

DBATU · Third Year B.Tech Electrical Engineering · NEP 2020

Power Quality Issue

26AF1293PE605B · Elective III · Semester VI · 3 credits · Continuous assessment 20 + mid-semester 20 + end-semester 60

One of the Elective III options.

All notes for this subject
  1. Unit 1: Introduction; Voltage Sags and Interruptions

    6 hours

    Classes of power quality problems; sources of sags and interruptions; estimating sag performance; protection principles; end-user solutions and ride-through economics; motor-starting sags; fault-clearing issues.

    Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then

    • Power quality terms as per IEEE 1159
    • Voltage sags and interruptions
    • Voltage sag mitigation
    • Ride-through alternatives and motor starting sags
  2. Unit 2: Transient Overvoltages

    6 hours

    Sources and protection principles; protective devices; utility capacitor-switching transients; lightning protection; ferroresonance; load-switching problems; computer tools for transient analysis.

    Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then

    • Transient overvoltages and their control
    • Capacitor-switching transients
    • Lightning protection of utility systems
    • Ferroresonance
  3. Unit 3: Fundamentals of Harmonics

    6 hours

    Harmonic distortion of voltage and current; harmonics versus transients; quantities under non-sinusoidal conditions; indices; commercial-load sources and locating them; system response; effects; interharmonics.

    Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then

    • Harmonic indices and THD
    • Power under non-sinusoidal conditions
    • Sources of harmonics
    • Harmonic resonance
    • Effects of harmonics on machines, transformers and cables
    • Interharmonics
  4. Unit 4: Long-duration Voltage Variations

    6 hours

    Principles and devices of voltage regulation; utility regulators; capacitors for regulation and at end users; regulating with distributed resources; flicker.

    Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then

    • Voltage regulation devices
    • Power factor correction with capacitors
    • Voltage regulation with distributed resources
    • Voltage flicker
  5. Unit 5: Power Quality Monitoring

    6 hours

    Monitoring considerations; measuring instruments past and present; assessing measurement data; intelligent systems; monitoring standards.

    Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then

    • Power quality monitoring
    • Power quality analysers and EN 50160
    • Intelligent systems in power quality monitoring

Unit contents are summarised from the official DBATU syllabus . AiCanCode.org is not affiliated with Dr. Babasaheb Ambedkar Technological University (DBATU).