DBATU · Second Year B.Tech Electrical Engineering · NEP 2020
Power System
25AF1293PC401 · Semester IV · 3 credits · Continuous assessment 20 + mid-semester 20 + end-semester 60
Unit 1: Electrical Power Generation
6 hoursEvolution and layout of a power system; energy sources; thermal, hydro and nuclear power plants with block diagrams; alternator exciters and excitation systems; major equipment in generating stations.
Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then
- Structure of a power system
- Thermal, hydro and nuclear power plants
- Excitation systems of alternators
Unit 2: Electrical Design of Overhead Transmission Lines
6 hoursInductance and capacitance of single- and three-phase lines with symmetrical and unsymmetrical spacing; GMD and GMR; transposition, bundled conductors and the earth effect; skin, proximity and Ferranti effects; corona loss and its reduction.
Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then
- Inductance of a single-phase line
- GMR and GMD
- Inductance of three-phase lines and transposition
- Bundled conductors
- Capacitance of three-phase lines
- Effect of earth on capacitance
- Skin and proximity effects
- Corona and corona loss
Unit 3: Mechanical Design of Transmission Lines
6 hoursConductor materials, stranded copper and ACSR; insulators and supports; voltage distribution across a string and string efficiency; wind and ice loading; sag with equal and unequal supports.
Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then
- Conductor materials: copper and ACSR
- Types of overhead line insulators
- String efficiency
- Sag calculation for overhead lines
- Effect of ice and wind loading
- Sag with supports at unequal levels
Unit 4: Performance of Transmission Lines
6 hoursClassification of lines; short single- and three-phase lines and the effect of power factor; medium lines; long-line analysis; generalised constants; regulation and transmission efficiency.
Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then
- Classification of transmission lines
- Performance of short lines
- Nominal-T and nominal-pi models
- Long transmission lines
- ABCD constants
- Efficiency and regulation of lines
- Ferranti effect
Unit 5: AC and DC Distribution
6 hoursClassification, requirements and design of distribution systems; AC distribution calculations, unbalanced three-phase and four-wire star loads, ground detectors; DC distributors and the three-wire DC system.
Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then
- Classification and requirements of distribution systems
- AC distribution calculations
- Unbalanced three-phase four-wire loads
- DC distributors and the three-wire DC system
Unit contents are summarised from the official DBATU syllabus . AiCanCode.org is not affiliated with Dr. Babasaheb Ambedkar Technological University (DBATU).