DBATU Final Year Electrical syllabus

DBATU · Final Year B.Tech Electrical Engineering · Non-NEP

High Voltage Engineering

BTEEC701 · Semester VII · 4 credits · Continuous assessment 20 + mid-semester 20 + end-semester 60

All notes for this subject
  1. Unit 1: Introduction to High Voltage Engineering

    2 hours

    Electric field stresses and Poisson's equation; estimating and controlling electric stress; surge voltages, their distribution and control.

    Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then

    • Electric field stress and its control
    • Surge voltage distribution and control
  2. Unit 2: Conduction and Breakdown in Gases

    6 hours

    Gases as insulation; ionisation processes and Townsend's current growth; Townsend's criterion and breakdown in electronegative gases; time lags; streamer theory and Paschen's law; non-uniform fields, corona, glow and arc discharges.

    Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then

    • Ionisation processes in gases
    • Townsend's theory of breakdown
    • Breakdown in electronegative gases and time lags
    • Streamer theory
    • Paschen's law
    • Corona discharge
  3. Unit 3: Breakdown in Dielectric Materials

    8 hours

    Conduction and breakdown in pure and commercial liquids; intrinsic, electromechanical and thermal breakdown of solids; chemical deterioration, treeing, tracking and internal discharges; composite insulation; insulating materials in transformers, machines, breakers, cables and capacitors.

    Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then

    • Breakdown in liquid dielectrics
    • Breakdown in solid dielectrics
    • Treeing and tracking
    • Breakdown in composite insulation
    • Insulating materials in power apparatus
  4. Unit 4: Overvoltages due to Lightning and Switching

    8 hours

    Lightning and switching surges and other abnormal conditions; travelling waves on lines, reflection and transmission at junctions; protecting lines against overvoltages; insulation coordination, surge diverters and substation insulation levels.

    Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then

    • Lightning phenomenon
    • Switching surges
    • Travelling waves on transmission lines
    • Surge diverters and overvoltage protection
    • Insulation coordination
  5. Unit 5: Generation and Measurement of High Voltages and Currents

    10 hours

    Generating high DC, power-frequency AC, high-frequency AC and impulse voltages; standard impulse waveshapes; multistage Marx generators and switching surges; impulse currents; measuring high DC, AC and impulse voltages and currents.

    Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then

    • Generation of high DC voltages
    • Generation of high AC voltages
    • Generation of high-frequency AC voltages
    • Impulse voltage waveshape
    • Marx impulse generator
    • Impulse current generation
    • Measurement of high DC and AC voltages
    • Measurement of impulse voltages
    • Measurement of high currents
  6. Unit 6: Non-destructive Testing

    6 hours

    IEC and IS codes for high voltage tests; non-destructive testing; testing insulators, bushings, isolators, circuit breakers, cables, transformers and surge diverters; layout of high voltage laboratories.

    Examined in the 60-mark end-semester paper, and in the mid-semester exam if it is taught by then

    • IEC and IS codes for high voltage tests
    • Non-destructive testing of insulation
    • Testing of insulators and bushings
    • Testing of circuit breakers and transformers
    • Testing of cables and surge arresters
    • High voltage laboratory layout

Unit contents are summarised from the official DBATU syllabus . AiCanCode.org is not affiliated with Dr. Babasaheb Ambedkar Technological University (DBATU).