BAMU · Final Year B.E. Electrical Engineering · CBCS (2019)
Power System Protection
EEP/402 · Semester VII · 4 credits · CT 20 + theory 80
Unit 1: Introduction to Protective Relaying
4 hoursRequirements and desirable qualities of protective relaying, zones of protection and relaying terms; classification of protective schemes; current, potential and summation transformers.
Examined in the 80-mark end-semester paper
- Zones of protection
- Primary and backup protection
- Classification of protective relays and automatic reclosing
- CTs and VTs for protection
- Summation transformers and desirable qualities of relaying
Unit 2: Relays
8 hoursConstruction, working, characteristics and settings of electromagnetic relays; static, induction-type earth fault, directional, distance, differential, Translay, negative-sequence and electro-thermal relays.
Examined in the 80-mark end-semester paper
- Overcurrent and directional relays
- Induction relay, PSM and TSM
- Distance relays: impedance, reactance and mho
- Percentage differential relays
- Static relays
- Translay and negative sequence relays
Unit 3: Protection Schemes
8 hoursAlternator protection against stator and rotor faults, unbalance and overloading; transformer protection with harmonic restraint, restricted earth fault, frame leakage, Buchholz and Merz-Price; induction motor protection.
Examined in the 80-mark end-semester paper
- Alternator protection
- Transformer differential protection
- Buchholz relay and inrush
- Bus zone and frame leakage protection
- Induction motor protection
- Earth fault and phase fault protection
Unit 4: Protection of Transmission Lines
6 hoursDifferential, distance and carrier current protection of feeders, busbars and lines; protecting stations, substations and lines against lightning and travelling waves; lightning arresters, surge absorbers and the Peterson coil.
Examined in the 80-mark end-semester paper
- Three-zone distance protection
- Carrier protection and PLCC
- Protection of lines and substations against lightning
- Protection against travelling waves
- Surge absorbers and the Peterson coil
Unit 5: Circuit Breakers
10 hoursArc formation and interruption theories, restriking and recovery voltage, RRRV, resistance switching, current chopping and capacitive current; air-break, air-blast, minimum oil, SF6 and vacuum breakers, MCB and ELCB; ratings and selection.
Examined in the 80-mark end-semester paper
- Arc formation and interruption
- Restriking voltage and RRRV
- Current chopping
- Interruption of capacitive current
- Air-break, oil and air-blast circuit breakers
- SF6 circuit breaker
- Vacuum circuit breaker
- Circuit breaker ratings
Unit 6: Microprocessor Based Protective Relays
4 hoursMicroprocessor-based overcurrent, impedance, directional and reactance relays.
Examined in the 80-mark end-semester paper
- Microprocessor-based overcurrent and impedance relays
- Numerical relays
Unit contents are summarised from the official BAMU syllabus . AiCanCode.org is not affiliated with Dr. Babasaheb Ambedkar Marathwada University (BAMU).