BAMU · Final Year B.E. Electrical Engineering · CBCS (2019)
High Voltage Engineering
EEP/451 · Semester VIII · 4 credits · CT 20 + theory 80
Unit 1: Introduction to High Voltage Engineering
8 hoursElectric field stresses; gases, vacuum, liquids, solids and composites as insulators; estimating and controlling stress, numerical field computation; surge voltages; insulating materials in transformers, machines, breakers, cables, capacitors and bushings.
Examined in the 80-mark end-semester paper
- Electric field stress and its control
- Numerical methods for electric field computation
- Surge voltage distribution and control
- Insulating materials in power apparatus
Unit 2: Breakdown in Dielectric Materials
8 hoursCollision and ionisation processes, Townsend's criterion and Paschen's law; breakdown in pure and commercial liquids; intrinsic, electromechanical and thermal breakdown of solids; composite dielectrics.
Examined in the 80-mark end-semester paper
- Ionisation processes in gases
- Townsend's theory of breakdown
- Paschen's law
- Breakdown in liquid dielectrics
- Breakdown in solid dielectrics
- Breakdown in composite insulation
Unit 3: Generation and Measurement of High Voltages and Currents
10 hoursGenerating high DC, AC and impulse voltages and impulse currents, and tripping impulse generators; measuring high DC, AC and impulse voltages (Abraham voltmeter) and high currents; oscilloscopes for impulse measurement.
Examined in the 80-mark end-semester paper
- Generation of high DC voltages
- Generation of high AC voltages
- Marx impulse generator
- Impulse current generation
- Measurement of high DC and AC voltages
- Measurement of impulse voltages
- Measurement of high currents
Unit 4: Overvoltages and Insulation Coordination
6 hoursLightning, switching surges, faults and other causes of overvoltage; principles of insulation coordination on HV and EHV systems.
Examined in the 80-mark end-semester paper
- Lightning phenomenon
- Switching surges
- Insulation coordination
Unit 5: Testing of Materials and Electrical Apparatus
8 hoursThe Faraday cage in HV labs; DC resistivity, dielectric constant, loss factor and partial discharge measurements; testing transformers, insulators, bushings, isolators, breakers, cables and surge arresters; radio interference measurement.
Examined in the 80-mark end-semester paper
- High voltage laboratory layout
- Dielectric loss and partial discharge measurement
- Testing of insulators and bushings
- Testing of cables and surge arresters
- Testing of circuit breakers and transformers
- Radio interference (EMI) measurements
Unit contents are summarised from the official BAMU syllabus . AiCanCode.org is not affiliated with Dr. Babasaheb Ambedkar Marathwada University (BAMU).