BAMU Final Year Electrical syllabus

BAMU · Final Year B.E. Electrical Engineering · CBCS (2019)

Electrical Power Quality

EEP/491 · Elective II · Semester VIII · 4 credits · CT 20 + theory 80

One of the Elective II options.

All notes for this subject
  1. Unit 1: Introduction

    8 hours

    Power quality defined and why it matters; evaluation procedure; classes, causes and effects of power quality disturbances.

    Examined in the 80-mark end-semester paper

    • Power quality terms as per IEEE 1159
    • Causes and effects of power quality disturbances
  2. Unit 2: Power Quality Disturbances

    8 hours

    Voltage sags and interruptions and their mitigation; transient overvoltages and protection; long-duration voltage variations, regulating devices and flicker.

    Examined in the 80-mark end-semester paper

    • Voltage sags and interruptions
    • Voltage sag mitigation
    • Transient overvoltages and their control
    • Voltage regulation devices
    • Voltage flicker
  3. Unit 3: Harmonics

    8 hours

    Harmonic distortion, its sources and effects; voltage versus current harmonics; power under non-sinusoidal conditions; THD and TDD; harmonic control and mitigating devices; interharmonics and IEEE 519.

    Examined in the 80-mark end-semester paper

    • Sources of harmonics
    • Harmonic indices and THD
    • Power under non-sinusoidal conditions
    • Passive and active harmonic filters
    • IEEE 519 harmonic limits
    • Interharmonics
  4. Unit 4: Wiring and Grounding

    4 hours

    Reasons for grounding; wiring and grounding problems and their solutions.

    Examined in the 80-mark end-semester paper

    • Grounding and power quality
    • Wiring and grounding problems and solutions
  5. Unit 5: Power Quality Monitoring

    6 hours

    Monitoring considerations, site surveys and locations; power quality instruments; assessing measurement data; IEEE 1159.

    Examined in the 80-mark end-semester paper

    • Power quality monitoring
    • Power quality analysers and EN 50160
  6. Unit 6: Power Quality Reliability

    6 hours

    The impact of poor power quality on reliability, security and relaying; reliability indices.

    Examined in the 80-mark end-semester paper

    • Impact of poor power quality on reliability and relaying
    • Reliability indices and power quality

Unit contents are summarised from the official BAMU syllabus . AiCanCode.org is not affiliated with Dr. Babasaheb Ambedkar Marathwada University (BAMU).