Fluid properties and fluid statics

  • τ = μ·du/dy — Newton's law of viscosity; τ shear stress (Pa), μ dynamic viscosity (Pa·s), du/dy velocity gradient (1/s).
  • ν = μ/ρ — Kinematic viscosity (m²/s); ρ density (kg/m³).
  • p = p_atm + ρ·g·h — Absolute pressure at depth h (m) in a static liquid; gauge pressure is ρ·g·h (Pa); g = 9.81 m/s².
  • F = ρ·g·h_c·A — Hydrostatic force on a plane submerged surface; h_c depth of the centroid (m), A area (m²).
  • h_cp = h_c + I_G·sin²θ/(A·h_c) — Depth of the centre of pressure; I_G second moment of area about the centroidal axis (m⁴), θ angle of the surface with the free surface (90° for a vertical wall).
  • F_B = ρ_fluid·g·V_displaced — Archimedes' buoyant force (N).

Fluid kinematics and the continuity equation

  • ṁ = ρ·A·V — Mass flow rate (kg/s); A area (m²), V mean velocity (m/s).
  • A₁·V₁ = A₂·V₂ — Continuity for steady incompressible flow; Q = A·V volume flow rate (m³/s).
  • ∂u/∂x + ∂v/∂y + ∂w/∂z = 0 — Differential continuity for incompressible flow.
  • ω_z = ½·(∂v/∂x − ∂u/∂y) — Rotation about z (rad/s); flow is irrotational when ω = 0 (vorticity = 2ω).

Bernoulli's equation and flow measurement

  • p₁/(ρg) + V₁²/(2g) + z₁ = p₂/(ρg) + V₂²/(2g) + z₂ — Bernoulli along a streamline: steady, incompressible, inviscid flow, no shaft work; each term in metres of head.
  • V = √(2·g·h) — Torricelli / pitot velocity; h head difference (m).
  • Q = C_d·A₁·A₂·√(2·g·h)/√(A₁² − A₂²) — Venturi or orifice meter; C_d discharge coefficient (≈ 0.95–0.99 venturi, ≈ 0.6 orifice — take from data), h = x·(ρ_m/ρ − 1) for a differential manometer reading x (m).

Laminar and turbulent flow in pipes; head losses

  • Re = ρ·V·D/μ = V·D/ν — Reynolds number (dimensionless); pipe flow laminar below about 2000–2300.
  • h_f = f·(L/D)·V²/(2g) — Darcy–Weisbach head loss (m); f Darcy friction factor, L length (m), D diameter (m).
  • f = 64/Re — Darcy friction factor, fully developed laminar flow.
  • f = 0.316·Re^(−0.25) — Blasius, smooth pipe, 4000 < Re < 10⁵.
  • Δp = 32·μ·V·L/D² — Hagen–Poiseuille pressure drop, laminar (Pa); V_max = 2·V.
  • h_L = K·V²/(2g) — Minor loss; K loss coefficient from tables; sudden expansion h_L = (V₁ − V₂)²/(2g).

Dimensional analysis

  • Number of π-groups = n − m — Buckingham π theorem; n variables, m fundamental dimensions (M, L, T, θ).
  • Fr = V/√(g·L), We = ρ·V²·L/σ_s, Eu = Δp/(ρ·V²), Ma = V/c — Froude, Weber, Euler, Mach numbers; σ_s surface tension (N/m), c speed of sound (m/s).
  • V_r = √L_r — Froude model law (gravity-dominated, e.g. open channels, ships); V_r = ν_r/L_r — Reynolds model law (viscous flow in pipes).

Systems, properties, work and heat

  • W = ∫p·dV — Boundary work of a quasi-static process (J); positive when done by the system.
  • W = p·(V₂ − V₁) — Constant pressure; W = p₁V₁·ln(V₂/V₁) — isothermal ideal gas; W = (p₁V₁ − p₂V₂)/(n − 1) — polytropic p·Vⁿ = const, n ≠ 1.
  • p·V = m·R·T — Ideal gas; R = R_u/M, R_u = 8.314 kJ/kmol·K; R_air = 0.287 kJ/kg·K; T in K.

First law of thermodynamics for closed and open systems

  • Q − W = ΔU — Closed system (Q into, W by the system, J).
  • ΔU = m·c_v·ΔT, ΔH = m·c_p·ΔT, c_p − c_v = R, γ = c_p/c_v — Ideal gas.
  • Q̇ − Ẇ_s = ṁ·[(h₂ − h₁) + (V₂² − V₁²)/2 + g·(z₂ − z₁)] — Steady-flow energy equation; h specific enthalpy (J/kg).
  • h₁ = h₂ — Throttling valve (adiabatic, no work, negligible KE change).

Second law, Carnot cycle and entropy

  • η_Carnot = 1 − T_L/T_H — Reversible engine between reservoirs at T_H and T_L (K).
  • COP_R = T_L/(T_H − T_L), COP_HP = T_H/(T_H − T_L) — Reversible refrigerator and heat pump; COP_HP = COP_R + 1.
  • dS = δQ_rev/T — Entropy change (J/K); ∮δQ/T ≤ 0 — Clausius inequality.
  • Δs = c_p·ln(T₂/T₁) − R·ln(p₂/p₁) — Ideal-gas entropy change (J/kg·K).
  • S_gen ≥ 0 — Entropy generation; zero only for reversible processes.

Air-standard cycles: Otto, Diesel and Brayton

  • η_Otto = 1 − 1/r^(γ − 1) — r compression ratio V₁/V₂.
  • η_Diesel = 1 − [1/r^(γ − 1)]·(r_c^γ − 1)/[γ·(r_c − 1)] — r_c cut-off ratio V₃/V₂.
  • η_Brayton = 1 − 1/r_p^((γ − 1)/γ) — r_p pressure ratio p_max/p_min.
  • r_p,opt = (T_max/T_min)^(γ/(2(γ − 1))) — Brayton pressure ratio for maximum net work.
  • MEP = W_net/(V₁ − V₂) — Mean effective pressure (Pa).

Vapour power cycle: Rankine cycle

  • η = (w_T − w_P)/q_in = [(h₁ − h₂) − (h₄ − h₃)]/(h₁ − h₄) — 1 turbine inlet, 2 turbine exit, 3 condenser exit, 4 pump exit; h from steam tables (kJ/kg).
  • w_P = v₃·(p₄ − p₃) — Pump work (kJ/kg) with v in m³/kg and p in kPa.
  • x = (h − h_f)/h_fg — Dryness fraction of wet steam.
  • η_T = (h₁ − h₂)/(h₁ − h₂s) — Isentropic turbine efficiency.
  • SSC = 3600/w_net — Specific steam consumption (kg/kWh), w_net in kJ/kg.

Refrigeration and air conditioning basics

  • COP = q_L/w = (h₁ − h₄)/(h₂ − h₁) — Vapour-compression cycle: 1 evaporator exit, 2 compressor exit, 3 condenser exit, 4 after throttle (h₄ = h₃).
  • 1 TR = 3.5167 kW — Ton of refrigeration (≈ 211 kJ/min).
  • ω = 0.622·p_v/(p − p_v) — Specific humidity (kg vapour/kg dry air); p_v partial pressure of vapour.
  • φ = p_v/p_sat — Relative humidity at the dry-bulb temperature.

One-dimensional steady conduction and fins

  • Q = −k·A·dT/dx — Fourier's law (W); k (W/m·K).
  • R_wall = L/(k·A), R_cyl = ln(r₂/r₁)/(2π·k·L), R_sph = (r₂ − r₁)/(4π·k·r₁·r₂), R_conv = 1/(h·A) — Thermal resistances (K/W); Q = ΔT/ΣR.
  • r_crit = k/h (cylinder), r_crit = 2k/h (sphere) — Critical radius of insulation (m).
  • m = √(h·P/(k·A_c)) — Fin parameter (1/m); P perimeter (m), A_c cross-section (m²).
  • Q_fin = √(h·P·k·A_c)·θ_b·tanh(m·L) — Fin with insulated tip; θ_b = T_b − T_∞ (K). Infinite fin: tanh(mL) → 1.
  • η_fin = tanh(m·L)/(m·L) — Efficiency of an insulated-tip fin.

Convective heat transfer coefficients and correlations

  • Q = h·A·(T_s − T_∞) — Newton's law of cooling; h (W/m²·K).
  • Nu = h·L/k_f, Pr = μ·c_p/k_f = ν/α, Gr = g·β·ΔT·L³/ν², Ra = Gr·Pr — Nusselt, Prandtl, Grashof, Rayleigh numbers; k_f fluid conductivity.
  • Nu = 0.023·Re^0.8·Pr^n — Dittus–Boelter, turbulent tube flow; n = 0.4 heating, 0.3 cooling.
  • Nu = 3.66 (constant wall temperature), Nu = 4.36 (constant heat flux) — Fully developed laminar tube flow.
  • Nu_x = 0.332·Re_x^0.5·Pr^(1/3), Nu_L = 0.664·Re_L^0.5·Pr^(1/3) — Laminar flat plate.
  • δ/x = 5/√Re_x — Laminar velocity boundary layer thickness (Blasius).
  • Bi = h·L_c/k_s — Biot number; lumped analysis valid if Bi < 0.1, L_c = V/A.
  • (T − T_∞)/(T_i − T_∞) = exp(−h·A·t/(ρ·V·c)) — Lumped-capacity transient cooling.

Radiation heat transfer basics

  • E_b = σ·T⁴ — Black-body emissive power (W/m²); σ = 5.67 × 10⁻⁸ W/m²·K⁴; T in K.
  • λ_max·T = 2898 μm·K — Wien's displacement law.
  • α + ρ + τ = 1; opaque: α + ρ = 1; Kirchhoff (grey surface): ε = α.
  • A₁·F₁₂ = A₂·F₂₁, ΣF₁ⱼ = 1 — View-factor reciprocity and summation; F₁₁ = 0 for flat or convex surfaces.
  • Q = ε₁·σ·A₁·(T₁⁴ − T₂⁴) — Small grey body in large surroundings (W).
  • q = σ·(T₁⁴ − T₂⁴)/(1/ε₁ + 1/ε₂ − 1) — Infinite parallel grey plates (W/m²).
  • Q = σ·A₁·(T₁⁴ − T₂⁴)/[1/ε₁ + (A₁/A₂)·(1/ε₂ − 1)] — Concentric cylinders or spheres, 1 inner.
  • q_N = q₀/(N + 1) — N shields, all emissivities equal to the plates'.

Heat exchangers

  • Q = U·A·ΔT_lm — Heat exchanger rate (W).
  • ΔT_lm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂) — Parallel flow ΔT₁ = T_h,i − T_c,i, ΔT₂ = T_h,o − T_c,o; counterflow ΔT₁ = T_h,i − T_c,o, ΔT₂ = T_h,o − T_c,i.
  • 1/U = 1/h_i + R_f,i + t/k + R_f,o + 1/h_o — Overall coefficient, thin plane wall; R_f fouling resistance (m²·K/W).
  • ε = Q/[C_min·(T_h,i − T_c,i)], NTU = U·A/C_min, C_r = C_min/C_max — C = ṁ·c_p (W/K).
  • ε = [1 − exp(−NTU·(1 + C_r))]/(1 + C_r) — Parallel flow.
  • ε = [1 − exp(−NTU·(1 − C_r))]/[1 − C_r·exp(−NTU·(1 − C_r))] — Counterflow; ε = NTU/(1 + NTU) when C_r = 1.
  • ε = 1 − exp(−NTU) — Condenser or evaporator (C_r = 0), any arrangement.

Heat transfer in casting, welding and machining

  • t_s = B·(V/A)² — Chvorinov's rule; t_s solidification time, V/A casting modulus (m), B empirical mould constant (s/m²); cube V/A = a/6, sphere and cylinder with H = D: D/6.
  • H = η_h·V·I/v — Weld heat input per unit length (J/mm); V arc voltage (V), I current (A), v travel speed (mm/s), η_h heat transfer efficiency.
  • A_w = η_m·η_h·V·I/(u·v) — Weld bead cross-section (mm²); η_m melting efficiency, u unit melting energy (J/mm³, data-book value).
  • P_c = F_c·v, u_s = P_c/MRR, MRR = f·d·v — Cutting power (W), specific cutting energy (J/mm³), material removal rate in turning.
  • ΔT_chip = x·P_c/(ρ·c·MRR) — Mean chip temperature rise; x fraction of heat carried by the chip.