Limits, Fits and Tolerances; Limit Gauge Design
T = UL − LL— Tolerance T (mm) of one part; UL, LL = upper and lower limits of size (mm).ES = UL_hole − basic size,EI = LL_hole − basic size— Upper and lower deviations of a hole (mm); for a shaft use lower-case es, ei.Maximum clearance = UL_hole − LL_shaft,Minimum clearance (allowance) = LL_hole − UL_shaft— A negative result is an interference (mm).i = 0.45·∛D + 0.001·D— Standard tolerance unit i (µm); D (mm) = geometric mean √(D₁·D₂) of the diameter step; sizes up to 500 mm. IT grades are multiples of i (e.g. IT7 = 16i, IT8 = 25i).Gauge tolerance ≈ 0.1 × work tolerance,Wear allowance ≈ 0.1 × gauge tolerance— Common conventions for limit-gauge design (Taylor's principle: GO gauge checks the maximum-material limit in full form, NO-GO the least-material limit at one point); use values stated in the question or standard.
Geometric Dimensioning and Tolerancing
Positional deviation (diametral) = 2·√(Δx² + Δy²)— Δx, Δy = measured deviations of the feature axis from true position (mm).Bonus (hole) = actual size − MMC size,Bonus (shaft) = MMC size − actual size— Extra position tolerance available when the feature departs from MMC (mm).Allowed position tolerance = stated tolerance at MMC + bonus(mm).Virtual condition (hole) = MMC − geometric tolerance,Virtual condition (shaft) = MMC + geometric tolerance(mm).
Linear and Angular Measurement
LC (vernier) = 1 MSD − 1 VSD = s / n— Least count; s = main-scale division (mm), n = number of vernier divisions spanning (n − 1) main-scale divisions.LC (micrometer) = p / N— p = screw pitch (mm), N = thimble divisions.Reading = MSR + VC × LC − zero error— MSR = main-scale reading, VC = coinciding vernier division; a positive zero error is subtracted.sin θ = h / L— Sine bar: h = slip-gauge stack height (mm), L = distance between roller centres (mm, e.g. 100 or 200).dθ = dh / (L·cos θ)— Error in angle (rad) for an error dh in stack height; sine bars become inaccurate above about 45°.
Comparators and Interferometry
M = output movement / input movement— Magnification; for levers in seriesM = (l₁/l₂)·(l₃/l₄)…; optical leverM = 2D / x(D = scale distance, x = arm length).h = n·λ/2— Height difference h (µm) for n fringes with light of wavelength λ (µm); each fringe = λ/2.h = (λ/2)·(n/l)·L— Height difference of two slip gauges compared with an optical flat: n fringes over length l of one gauge, L = distance between the gauges' contact points.
Surface Roughness Measurement
Ra = (1/L)·∫₀ᴸ |y| dx ≈ (1/n)·Σ|yᵢ|— Arithmetic mean deviation from the mean line (µm) over evaluation length L.Rq = √[(1/n)·Σyᵢ²]— Root-mean-square roughness (µm).Rz = (1/5)·ΣZᵢ— Mean of the peak-to-valley heights of five sampling lengths (µm).Ra = (A₁ + A₂) / (L_chart · V)— From a recorded trace: A₁, A₂ = areas above and below the mean line on the chart, L_chart = chart length, V = vertical magnification (horizontal scale cancels if L_chart is on the same chart).Rt ≈ f² / (8r),Ra ≈ Rt / 4— Ideal turned surface with tool nose radius r and feed f (same length units); Rt/4 holds for an ideal symmetric triangular profile.
Measurement of Screw Threads and Gears
Lead = n_s · p— n_s = number of starts, p = pitch (mm).d_best = p / [2·cos(θ/2)]— Best-size wire diameter; θ = included thread angle (for 60°: 0.5774·p).E = M − d·[1 + cosec(θ/2)] + (p/2)·cot(θ/2)— Effective diameter by the three-wire method; M = measurement over wires, d = wire diameter (mm). For θ = 60°:E = M − 3d + 0.8660·p.E = D − 0.6495·p— Basic effective (pitch) diameter of an ISO metric thread of major diameter D.w = N·m·sin(90°/N),h = m·[1 + (N/2)·(1 − cos(90°/N))]— Gear tooth vernier: chordal tooth thickness w and chordal addendum h at the pitch circle; N = number of teeth, m = module (mm).W = m·cos φ·[π·(S − 0.5) + N·inv φ],inv φ = tan φ − φ— Base tangent (span) length over S teeth; φ = pressure angle (rad in inv φ).
Coordinate Measuring Machines
L = √[(x₂ − x₁)² + (y₂ − y₁)² + (z₂ − z₁)²]— Distance between two measured points (mm).D_bore = D_centres + d_ball,D_shaft = D_centres − d_ball— Probe-radius compensation; D_centres = diameter of the circle through recorded ball centres, d_ball = stylus ball diameter (mm).ΔL = L·α·ΔT— Thermal length change (mm); α = coefficient of expansion (1/°C), ΔT = departure from 20 °C reference.- Minimum points: line 2, plane 3, circle 3, sphere 4, cylinder 5, cone 6 (more are needed to assess form).
Alignment Testing of Machine Tools
θ = h / L— Slope or angular misalignment (rad) from a deviation h over length L (same units); small angles.h = n · S · L_b— Height difference across a spirit-level base; n = bubble divisions, S = sensitivity (mm/m per division ÷ 1000), L_b = base length (mm).θ_div = l / R— Angle per vial division; l = division length, R = vial radius of curvature.e = TIR / 2— Eccentricity from the total indicator reading on a rotating feature.d_axis = (r₀ + r₁₈₀) / 2— True spindle-axis position from mandrel readings at 0° and 180°.1 rad = 206 265″;0.01 mm/m ≈ 2.06″.
Quality Concepts and Cost of Quality
CoQ = C_P + C_A + C_IF + C_EF— Prevention + appraisal + internal failure + external failure costs (₹ per period).CoQ % = CoQ / Sales × 100.L(y) = k·(y − m)²,k = A₀ / Δ₀²— Taguchi loss per part (₹); m = target, A₀ = loss at the customer tolerance Δ₀.L̄ = k·[σ² + (ȳ − m)²]— Expected loss per part for a process with mean ȳ and standard deviation σ.
Control Charts for Variables: X-bar and R
X̿ = ΣX̄ᵢ / k,R̄ = ΣRᵢ / k— Grand mean and average range over k subgroups.UCL = X̿ + A₂·R̄,LCL = X̿ − A₂·R̄— X-bar chart limits; A₂ = 3/(d₂·√n).UCL = D₄·R̄,LCL = D₃·R̄— R chart limits.σ̂ = R̄ / d₂,σ_X̄ = σ / √n— Process σ from ranges; standard deviation of subgroup means.- Factors: n = 4: A₂ = 0.729, D₃ = 0, D₄ = 2.282, d₂ = 2.059; n = 5: A₂ = 0.577, D₃ = 0, D₄ = 2.114, d₂ = 2.326 (other n from the SQC table).
ARL = 1 / p— Average run length; p = probability a point falls outside the limits (0.0027 for an in-control process with 3σ limits, ARL ≈ 370).
Control Charts for Attributes: p, np, c and u
p̄ = Σd / Σn,UCL/LCL = p̄ ± 3·√[p̄(1 − p̄)/n]— p chart (fraction defective); d = defectives, n = sample size.UCL/LCL = n·p̄ ± 3·√[n·p̄(1 − p̄)]— np chart (number defective), constant n.c̄ = Σc / k,UCL/LCL = c̄ ± 3·√c̄— c chart (defects per inspection unit of constant size).ū = Σc / Σn,UCL/LCL = ū ± 3·√(ū/n)— u chart (defects per unit, n may vary).- A negative LCL is set to 0.
Process Capability: Cp and Cpk
Cp = (USL − LSL) / (6σ)— Potential capability; USL, LSL = specification limits, σ = process standard deviation.Cpk = min[(USL − μ)/(3σ), (μ − LSL)/(3σ)]— Actual capability; μ = process mean. Cpk ≤ Cp, equal only when centred.Cpk = Cp·(1 − k),k = |M − μ| / [(USL − LSL)/2]— M = mid-point of the tolerance.Cpm = (USL − LSL) / (6·√[σ² + (μ − T)²])— Taguchi capability index; T = target.Fraction above USL = 1 − Φ[(USL − μ)/σ]— Φ = standard normal CDF.
Acceptance Sampling: OC Curves, Single and Double Sampling
Pa = Σ(d = 0 to c) C(n, d)·pᵈ·(1 − p)ⁿ⁻ᵈ— Probability of acceptance, single plan (n, c), lot fraction defective p (binomial).Pa ≈ Σ(d = 0 to c) e^(−λ)·λᵈ/d!,λ = n·p— Poisson approximation.α = 1 − Pa(AQL),β = Pa(LTPD)— Producer's and consumer's risks.AOQ = Pa·p·(N − n)/N— Average outgoing quality with rectifying inspection; N = lot size; AOQL = its maximum over p.ATI = n + (1 − Pa)·(N − n)— Average total inspection per lot.Pa = P(d₁ ≤ c₁) + Σ(c₁ < d₁ ≤ c₂) P(d₁)·P(d₂ ≤ c₂ − d₁),ASN = n₁ + n₂·P(c₁ < d₁ ≤ c₂)— Double sampling.
Reliability: Failure Rate, Bathtub Curve and MTBF
R(t) = 1 − F(t),h(t) = f(t) / R(t),R(t) = exp[−∫₀ᵗ h dt]— Reliability, hazard rate (h⁻¹), failure density f.R(t) = e^(−λt),MTTF = 1/λ— Constant failure rate λ (h⁻¹); R(MTTF) = e⁻¹ = 0.368.λ̂ = r / ΣTᵢ,MTBF = ΣTᵢ / r— r failures in total operating time ΣTᵢ (h).h(interval) = n_f / (N_s·Δt)— Hazard from test data; N_s = survivors at the start of the interval.A = MTBF / (MTBF + MTTR)— Inherent availability.R(t) = exp[−(t/η)^β]— Weibull; β < 1 infant mortality, β = 1 constant, β > 1 wear-out; η = characteristic life.
Series, Parallel and Standby System Reliability
R_s = R₁·R₂·…·Rₙ,λ_s = Σλᵢ,MTTF_s = 1/Σλᵢ— Series system.R_p = 1 − (1 − R₁)(1 − R₂)…(1 − Rₙ)— Active parallel; two identical exponential units:MTTF = 3/(2λ).R = Σ(i = k to n) C(n, i)·Rⁱ·(1 − R)ⁿ⁻ⁱ— k-out-of-n; 2-out-of-3:R = 3R² − 2R³.R_sb = e^(−λt)·(1 + λt),MTTF = 2/λ— Two identical units in cold standby, perfect switch; with switch reliability R_sw:R_sb = e^(−λt)·(1 + R_sw·λt).
Maintenance Planning and Total Productive Maintenance
MTBF = operating time / failures,MTTR = repair time / repairs(h).OEE = Availability × Performance × Quality— Availability = operating time / planned production time; Performance = ideal cycle time × total count / operating time; Quality = good count / total count.Bₙ = N·(p₁ + … + pₙ) + B₁·pₙ₋₁ + … + Bₙ₋₁·p₁— Expected breakdowns in n periods after group preventive service of N machines; pᵢ = probability of failure in period i.Cost per period = (N·c_pm + c_bd·ΣBᵢ) / n(PM every n periods); breakdown only:N·c_bd / Σ(i·pᵢ).
Total Quality Management and ISO 9001
ppm = nonconforming / supplied × 10⁶— Parts per million defective.Payback = project cost / annual saving,Annual saving = Δ(defect fraction) × annual volume × cost per defective.
Six Sigma and Quality Tools
DPU = D / U,DPO = D / (U·O),DPMO = DPO × 10⁶— D = defects, U = units, O = opportunities per unit.Sigma level ≈ z(1 − DPO) + 1.5— With the conventional 1.5σ long-term shift; 6σ ↔ 3.4 DPMO, 4σ ↔ 6210 DPMO, 3σ ↔ 66 807 DPMO.FPY ≈ e^(−DPU),RTY = FPY₁·FPY₂·…·FPYₖ— First-pass and rolled throughput yield.RPN = S × O × D— FMEA risk priority number (each rating 1–10).