Thermal Engineering — formula sheet
Mechatronics Engineering · GATE ME · SI units. Drafted with Aria, checked by the AiCanCode.org team.
Systems, properties, work and heat
W = ∫ p dV— boundary (displacement) work done by a closed system; W (J), p: pressure (Pa), V: volume (m³); quasi-static processes only.W = p (V₂ − V₁)— constant-pressure process (J).W = p₁V₁ ln(V₂/V₁)— isothermal ideal-gas process (J).W = (p₁V₁ − p₂V₂)/(n − 1)— polytropic process pVⁿ = constant, n ≠ 1 (J).Q = m c ΔT— sensible heat; m: mass (kg), c: specific heat (J/kg·K), ΔT: temperature change (K).T(K) = T(°C) + 273.15— absolute temperature; use kelvin in all ratio and gas-law formulas.
Properties of pure substances and steam tables
v = V/m— specific volume (m³/kg).x = m_vapour / (m_liquid + m_vapour)— dryness fraction of a wet mixture (dimensionless).v = v_f + x v_fg,h = h_f + x h_fg,s = s_f + x s_fg— wet-mixture properties from saturation tables; subscripts f: saturated liquid, g: saturated vapour, fg = g − f.h = u + p v— specific enthalpy (J/kg); u: specific internal energy (J/kg).h ≈ h_f(T)— compressed liquid approximation at the same temperature when compressed-liquid tables are not given.
First law for closed systems and steady-flow devices
Q − W = ΔU— closed system; Q: heat added to the system (J), W: work done by the system (J), ΔU: change of internal energy (J).Q̇ − Ẇ = ṁ [(h₂ − h₁) + (V₂² − V₁²)/2 + g(z₂ − z₁)]— steady-flow energy equation; Q̇, Ẇ (W), ṁ (kg/s), h (J/kg), V: velocity (m/s), z: elevation (m).Ẇ_turbine = ṁ (h₁ − h₂)— adiabatic turbine, negligible kinetic and potential energy changes (W).V₂ = √(2(h₁ − h₂) + V₁²)— adiabatic nozzle exit velocity (m/s), h in J/kg.h₂ = h₁— throttling valve (isenthalpic).Δu = c_v ΔT,Δh = c_p ΔT— ideal gas (J/kg); c_v, c_p (J/kg·K).
Second law, Carnot cycle and entropy
η = W_net/Q_H = 1 − Q_L/Q_H— heat-engine efficiency; Q_H: heat supplied, Q_L: heat rejected (J).η_Carnot = 1 − T_L/T_H— reversible engine between reservoirs at T_H and T_L (K).COP_R,Carnot = T_L/(T_H − T_L),COP_HP,Carnot = T_H/(T_H − T_L)— reversible refrigerator and heat pump.dS = δQ_rev / T— entropy change (J/K) along a reversible path; for any process S₂ − S₁ ≥ ∫ δQ/T.Δs = c_p ln(T₂/T₁) − R ln(p₂/p₁)— ideal-gas entropy change (J/kg·K), valid for any process between the two states.∮ δQ/T ≤ 0— Clausius inequality (= 0 for a reversible cycle).
Availability and irreversibility
ψ = (h − h₀) − T₀(s − s₀) + V²/2 + g z— specific flow exergy (J/kg); subscript 0: dead state, T₀ in K.Q-exergy = Q (1 − T₀/T)— available part of heat Q supplied at constant temperature T (J).I = T₀ S_gen— irreversibility (Gouy–Stodola); S_gen: entropy generated (J/K).η_II = W_actual / W_rev— second-law efficiency for work-producing devices.
Ideal gas mixtures and thermodynamic relations
p V = m R T,R = R̄ / M— ideal gas; R̄ = 8.314 kJ/kmol·K, M: molar mass (kg/kmol), R (J/kg·K).c_p − c_v = R,γ = c_p/c_v— ideal gas.p_i = y_i p,y_i = n_i / n— Dalton's law; partial pressure and mole fraction.M_mix = Σ y_i M_i,c_p,mix = Σ (m_i/m) c_p,i— mixture molar mass and specific heat.(∂T/∂v)_s = −(∂p/∂s)_vand the other Maxwell relations — from du = T ds − p dv, dh = T ds + v dp.dp/dT = h_fg / (T v_fg)— Clapeyron equation for a phase change.
Rankine cycle with reheat and regeneration
η = (w_t − w_p)/q_in— Rankine efficiency; w_t: turbine work, w_p: pump work, q_in: boiler heat (all kJ/kg).w_p = v (p₂ − p₁)— pump work for a liquid (kJ/kg with v in m³/kg and p in kPa).q_in = (h₃ − h₂) + (h₅ − h₄)— with one reheat (kJ/kg).y = (h₆ − h₂)/(h_bleed − h₂)— fraction bled to an open feedwater heater; h₂: feedwater entering, h₆: saturated liquid leaving (kJ/kg).SSC = 3600 / w_net— specific steam consumption (kg/kWh) with w_net in kJ/kg.
Brayton cycle and gas turbines
η = 1 − 1/r_p^((γ−1)/γ)— ideal Brayton cycle; r_p = p₂/p₁: pressure ratio.T₂/T₁ = r_p^((γ−1)/γ)— isentropic compression (temperatures in K).w_net = c_p[(T₃ − T₄) − (T₂ − T₁)]— net work (J/kg).r_p,opt = (T₃/T₁)^(γ/(2(γ−1)))— pressure ratio for maximum net work, ideal cycle.η_C = (T₂s − T₁)/(T₂ − T₁),η_T = (T₃ − T₄)/(T₃ − T₄s)— isentropic efficiencies of compressor and turbine.ε_regen = (T_x − T₂)/(T₄ − T₂)— regenerator effectiveness.
Air-standard Otto, Diesel and dual cycles
η_Otto = 1 − 1/r^(γ−1)— r = V₁/V₂: compression ratio.η_Diesel = 1 − (1/r^(γ−1)) · (ρ^γ − 1)/(γ(ρ − 1))— ρ = V₃/V₂: cut-off ratio.η_dual = 1 − (1/r^(γ−1)) · (α ρ^γ − 1)/[(α − 1) + γ α (ρ − 1)]— α = p₃/p₂: pressure ratio during constant-volume heat addition.MEP = W_net / V_s— mean effective pressure (Pa); V_s: swept volume (m³).V_s = (π/4) D² L,r = (V_s + V_c)/V_c— swept volume and compression ratio; D: bore, L: stroke (m), V_c: clearance volume.
IC engine performance and combustion basics
BP = 2π N T / 60— brake power (W); N: speed (rpm), T: torque (N·m).IP = p_mi L A n K— indicated power (W); p_mi: indicated mean effective pressure (Pa), L: stroke (m), A: piston area (m²), n: power strokes per second per cylinder (N/120 for four-stroke, N/60 for two-stroke, N in rpm), K: number of cylinders.η_m = BP / IP,FP = IP − BP— mechanical efficiency and friction power.η_bth = BP / (ṁ_f · CV)— brake thermal efficiency; ṁ_f: fuel rate (kg/s), CV: calorific value (J/kg).bsfc = ṁ_f / BP— brake specific fuel consumption (kg/J; usually quoted in kg/kWh).η_v = V̇_actual / V̇_swept— volumetric efficiency, with air density at intake conditions.
Steam turbines: impulse and reaction staging
η_is = (h₁ − h₂)/(h₁ − h₂s)— turbine isentropic efficiency; h: specific enthalpy (kJ/kg), 2s: isentropic exit state.W = ṁ U (V_w1 ± V_w2)— blade work (W); U: blade speed (m/s), V_w: whirl components (m/s); + when the exit whirl is opposite to the inlet whirl.η_b = 2 U (V_w1 ± V_w2) / V₁²— blade (diagram) efficiency of an impulse stage; V₁: absolute inlet velocity (m/s).U/V₁ = cos α₁ / 2,η_b,max = cos² α₁— optimum single-stage impulse (symmetric blades, no friction); α₁: nozzle angle.U/V₁ = cos α₁,η_b,max = 2cos² α₁ / (1 + cos² α₁)— optimum 50 % reaction (Parsons) stage.R = Δh_rotor / Δh_stage— degree of reaction.
Vapour compression and vapour absorption refrigeration
COP_R = Q_L / W = (h₁ − h₄)/(h₂ − h₁)— vapour-compression cycle; 1: compressor inlet, 2: compressor outlet, 4: evaporator inlet (h₄ = h₃ by throttling).RE = h₁ − h₄— refrigerating effect (kJ/kg).1 TR = 3.517 kW— tonne of refrigeration (approximately 211 kJ/min).COP_absorption = Q_evap / (Q_generator + W_pump)— vapour absorption system.COP_absorption,max = (1 − T₀/T_G) · T_E/(T₀ − T_E)— ideal limit; T_G: generator, T₀: ambient, T_E: evaporator temperature (K).
Psychrometry and air conditioning load
ω = 0.622 p_v / (p − p_v)— humidity ratio (kg vapour/kg dry air); p_v: vapour partial pressure, p: total pressure (Pa).φ = p_v / p_s— relative humidity; p_s: saturation pressure at the dry-bulb temperature.μ = ω / ω_s— degree of saturation.h = 1.005 t + ω (2501 + 1.88 t)— moist-air enthalpy (kJ/kg dry air), t in °C.Q_s = ṁ_a c_pma (t₁ − t₂),Q_L = ṁ_a h_fg (ω₁ − ω₂)— sensible and latent loads (kW).SHF = Q_s / (Q_s + Q_L),BPF = (t_out − t_coil)/(t_in − t_coil)— sensible heat factor and coil bypass factor.
One-dimensional steady conduction and fins
Q = −k A dT/dx— Fourier's law; Q (W), k (W/m·K), A: area normal to heat flow (m²), dT/dx (K/m).R_wall = L/(kA),R_cyl = ln(r₂/r₁)/(2π k L),R_conv = 1/(hA)— thermal resistances (K/W).r_c = k_ins / h(cylinder),2k_ins/h(sphere) — critical radius of insulation (m).T_max = T_s + q̇ L²/(2k)— plane wall of half-thickness L with generation q̇ (W/m³).m = √(hP/(kA_c))— fin parameter (1/m); P: perimeter (m), A_c: cross-section (m²).Q_fin = √(hPkA_c) θ_b tanh(mL)— insulated-tip fin; θ_b = T_b − T∞ (K); for a long fin replace tanh(mL) by 1; for a convective tip use L_c = L + A_c/P.η_f = tanh(mL)/(mL),ε_f = Q_fin/(h A_c θ_b)— fin efficiency and effectiveness.
Unsteady conduction: lumped capacitance and Heisler charts
Bi = h L_c / k_solid,L_c = V/A_s— Biot number; lumped model valid for Bi < 0.1 (L_c = r₀/3 sphere, r₀/2 long cylinder, half-thickness for a wall).Fo = α t / L²,α = k/(ρ c)— Fourier number and thermal diffusivity (m²/s).(T − T∞)/(Tᵢ − T∞) = exp(−hA_s t/(ρVc))— lumped body.τ = ρ V c / (h A_s)— time constant (s).(T − T_s)/(Tᵢ − T_s) = erf[x/(2√(αt))]— semi-infinite solid with a step change in surface temperature.
Forced and natural convection
Q = h A (T_s − T∞)— Newton's law of cooling (W).Nu = hL/k_fluid,Re = VL/ν,Pr = μc_p/k,Gr = gβΔT L³/ν²,Ra = Gr·Pr— dimensionless groups; β = 1/T_f (K) for an ideal gas.Nu_L = 0.664 Re_L^0.5 Pr^(1/3)— laminar flat plate, average (Re_L < 5 × 10⁵).Nu_L = 0.037 Re_L^0.8 Pr^(1/3)— turbulent flat plate, average.Nu_D = 3.66(uniform wall temperature),4.36(uniform heat flux) — fully developed laminar pipe flow (Re_D < 2300).Nu_D = 0.023 Re_D^0.8 Prⁿ— Dittus–Boelter, n = 0.4 heating, 0.3 cooling (Re_D > 10 000).Nu = C Raⁿ— natural convection; C and n from the data book for the geometry and range.
Radiation: black body, view factors and radiosity networks
E_b = σ T⁴— black-body emissive power (W/m²); σ = 5.67 × 10⁻⁸ W/m²·K⁴, T in K.λ_max T = 2898 μm·K— Wien's displacement law.α + ρ + τ = 1; gray surfaceε = α(Kirchhoff).Σ_j F_ij = 1,A_i F_ij = A_j F_ji— summation and reciprocity rules for view factors.J = ε E_b + (1 − ε) G— radiosity of an opaque gray surface (W/m²); G: irradiation.q = σ(T₁⁴ − T₂⁴)/(1/ε₁ + 1/ε₂ − 1)— large parallel plates (W/m²).Q = ε₁ σ A₁ (T₁⁴ − T₂⁴)— small body in a large enclosure (W).
Heat exchangers: LMTD and effectiveness-NTU methods
Q = U A ΔT_lm,ΔT_lm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂)— counterflow: ΔT₁ = T_h,in − T_c,out, ΔT₂ = T_h,out − T_c,in; parallel flow: ΔT₁ = T_h,in − T_c,in, ΔT₂ = T_h,out − T_c,out.Q = C_h (T_h,in − T_h,out) = C_c (T_c,out − T_c,in),C = ṁ c_p— energy balance (W).ε = Q / [C_min (T_h,in − T_c,in)],NTU = UA/C_min,C_r = C_min/C_max.ε = [1 − exp(−NTU(1 + C_r))]/(1 + C_r)— parallel flow.ε = [1 − exp(−NTU(1 − C_r))]/[1 − C_r exp(−NTU(1 − C_r))]— counterflow;ε = NTU/(1 + NTU)when C_r = 1.ε = 1 − exp(−NTU)— C_r = 0 (condensing or evaporating fluid), any arrangement.
Thermal management of electronics enclosures
T_j = T_a + P (R_jc + R_cs + R_sa)— junction temperature (°C); P: dissipation (W), R: junction-case, case-sink, sink-ambient resistances (K/W).R_sa,max = (T_j,max − T_a)/P − R_jc − R_cs— largest allowable heat-sink resistance (K/W).R_TIM = t/(k A)— thermal interface layer resistance (K/W); t: thickness (m).Q = h A (T_s − T_a) + ε σ A (T_s⁴ − T_a⁴)— heat lost by a sealed enclosure surface (W), radiation term in K.V̇ = Q/(ρ c_p ΔT_air)— fan airflow for an allowed air temperature rise (m³/s).