Thermal Engineering

Thermal Engineering — formula sheet

Mechatronics Engineering · GATE ME · SI units. Drafted with Aria, checked by the AiCanCode.org team.

Systems, properties, work and heat

  • W = ∫ p dV — boundary (displacement) work done by a closed system; W (J), p: pressure (Pa), V: volume (m³); quasi-static processes only.
  • W = p (V₂ − V₁) — constant-pressure process (J).
  • W = p₁V₁ ln(V₂/V₁) — isothermal ideal-gas process (J).
  • W = (p₁V₁ − p₂V₂)/(n − 1) — polytropic process pVⁿ = constant, n ≠ 1 (J).
  • Q = m c ΔT — sensible heat; m: mass (kg), c: specific heat (J/kg·K), ΔT: temperature change (K).
  • T(K) = T(°C) + 273.15 — absolute temperature; use kelvin in all ratio and gas-law formulas.

Properties of pure substances and steam tables

  • v = V/m — specific volume (m³/kg).
  • x = m_vapour / (m_liquid + m_vapour) — dryness fraction of a wet mixture (dimensionless).
  • v = v_f + x v_fg, h = h_f + x h_fg, s = s_f + x s_fg — wet-mixture properties from saturation tables; subscripts f: saturated liquid, g: saturated vapour, fg = g − f.
  • h = u + p v — specific enthalpy (J/kg); u: specific internal energy (J/kg).
  • h ≈ h_f(T) — compressed liquid approximation at the same temperature when compressed-liquid tables are not given.

First law for closed systems and steady-flow devices

  • Q − W = ΔU — closed system; Q: heat added to the system (J), W: work done by the system (J), ΔU: change of internal energy (J).
  • Q̇ − Ẇ = ṁ [(h₂ − h₁) + (V₂² − V₁²)/2 + g(z₂ − z₁)] — steady-flow energy equation; Q̇, Ẇ (W), ṁ (kg/s), h (J/kg), V: velocity (m/s), z: elevation (m).
  • Ẇ_turbine = ṁ (h₁ − h₂) — adiabatic turbine, negligible kinetic and potential energy changes (W).
  • V₂ = √(2(h₁ − h₂) + V₁²) — adiabatic nozzle exit velocity (m/s), h in J/kg.
  • h₂ = h₁ — throttling valve (isenthalpic).
  • Δu = c_v ΔT, Δh = c_p ΔT — ideal gas (J/kg); c_v, c_p (J/kg·K).

Second law, Carnot cycle and entropy

  • η = W_net/Q_H = 1 − Q_L/Q_H — heat-engine efficiency; Q_H: heat supplied, Q_L: heat rejected (J).
  • η_Carnot = 1 − T_L/T_H — reversible engine between reservoirs at T_H and T_L (K).
  • COP_R,Carnot = T_L/(T_H − T_L), COP_HP,Carnot = T_H/(T_H − T_L) — reversible refrigerator and heat pump.
  • dS = δQ_rev / T — entropy change (J/K) along a reversible path; for any process S₂ − S₁ ≥ ∫ δQ/T.
  • Δs = c_p ln(T₂/T₁) − R ln(p₂/p₁) — ideal-gas entropy change (J/kg·K), valid for any process between the two states.
  • ∮ δQ/T ≤ 0 — Clausius inequality (= 0 for a reversible cycle).

Availability and irreversibility

  • ψ = (h − h₀) − T₀(s − s₀) + V²/2 + g z — specific flow exergy (J/kg); subscript 0: dead state, T₀ in K.
  • Q-exergy = Q (1 − T₀/T) — available part of heat Q supplied at constant temperature T (J).
  • I = T₀ S_gen — irreversibility (Gouy–Stodola); S_gen: entropy generated (J/K).
  • η_II = W_actual / W_rev — second-law efficiency for work-producing devices.

Ideal gas mixtures and thermodynamic relations

  • p V = m R T, R = R̄ / M — ideal gas; R̄ = 8.314 kJ/kmol·K, M: molar mass (kg/kmol), R (J/kg·K).
  • c_p − c_v = R, γ = c_p/c_v — ideal gas.
  • p_i = y_i p, y_i = n_i / n — Dalton's law; partial pressure and mole fraction.
  • M_mix = Σ y_i M_i, c_p,mix = Σ (m_i/m) c_p,i — mixture molar mass and specific heat.
  • (∂T/∂v)_s = −(∂p/∂s)_v and the other Maxwell relations — from du = T ds − p dv, dh = T ds + v dp.
  • dp/dT = h_fg / (T v_fg) — Clapeyron equation for a phase change.

Rankine cycle with reheat and regeneration

  • η = (w_t − w_p)/q_in — Rankine efficiency; w_t: turbine work, w_p: pump work, q_in: boiler heat (all kJ/kg).
  • w_p = v (p₂ − p₁) — pump work for a liquid (kJ/kg with v in m³/kg and p in kPa).
  • q_in = (h₃ − h₂) + (h₅ − h₄) — with one reheat (kJ/kg).
  • y = (h₆ − h₂)/(h_bleed − h₂) — fraction bled to an open feedwater heater; h₂: feedwater entering, h₆: saturated liquid leaving (kJ/kg).
  • SSC = 3600 / w_net — specific steam consumption (kg/kWh) with w_net in kJ/kg.

Brayton cycle and gas turbines

  • η = 1 − 1/r_p^((γ−1)/γ) — ideal Brayton cycle; r_p = p₂/p₁: pressure ratio.
  • T₂/T₁ = r_p^((γ−1)/γ) — isentropic compression (temperatures in K).
  • w_net = c_p[(T₃ − T₄) − (T₂ − T₁)] — net work (J/kg).
  • r_p,opt = (T₃/T₁)^(γ/(2(γ−1))) — pressure ratio for maximum net work, ideal cycle.
  • η_C = (T₂s − T₁)/(T₂ − T₁), η_T = (T₃ − T₄)/(T₃ − T₄s) — isentropic efficiencies of compressor and turbine.
  • ε_regen = (T_x − T₂)/(T₄ − T₂) — regenerator effectiveness.

Air-standard Otto, Diesel and dual cycles

  • η_Otto = 1 − 1/r^(γ−1) — r = V₁/V₂: compression ratio.
  • η_Diesel = 1 − (1/r^(γ−1)) · (ρ^γ − 1)/(γ(ρ − 1)) — ρ = V₃/V₂: cut-off ratio.
  • η_dual = 1 − (1/r^(γ−1)) · (α ρ^γ − 1)/[(α − 1) + γ α (ρ − 1)] — α = p₃/p₂: pressure ratio during constant-volume heat addition.
  • MEP = W_net / V_s — mean effective pressure (Pa); V_s: swept volume (m³).
  • V_s = (π/4) D² L, r = (V_s + V_c)/V_c — swept volume and compression ratio; D: bore, L: stroke (m), V_c: clearance volume.

IC engine performance and combustion basics

  • BP = 2π N T / 60 — brake power (W); N: speed (rpm), T: torque (N·m).
  • IP = p_mi L A n K — indicated power (W); p_mi: indicated mean effective pressure (Pa), L: stroke (m), A: piston area (m²), n: power strokes per second per cylinder (N/120 for four-stroke, N/60 for two-stroke, N in rpm), K: number of cylinders.
  • η_m = BP / IP, FP = IP − BP — mechanical efficiency and friction power.
  • η_bth = BP / (ṁ_f · CV) — brake thermal efficiency; ṁ_f: fuel rate (kg/s), CV: calorific value (J/kg).
  • bsfc = ṁ_f / BP — brake specific fuel consumption (kg/J; usually quoted in kg/kWh).
  • η_v = V̇_actual / V̇_swept — volumetric efficiency, with air density at intake conditions.

Steam turbines: impulse and reaction staging

  • η_is = (h₁ − h₂)/(h₁ − h₂s) — turbine isentropic efficiency; h: specific enthalpy (kJ/kg), 2s: isentropic exit state.
  • W = ṁ U (V_w1 ± V_w2) — blade work (W); U: blade speed (m/s), V_w: whirl components (m/s); + when the exit whirl is opposite to the inlet whirl.
  • η_b = 2 U (V_w1 ± V_w2) / V₁² — blade (diagram) efficiency of an impulse stage; V₁: absolute inlet velocity (m/s).
  • U/V₁ = cos α₁ / 2, η_b,max = cos² α₁ — optimum single-stage impulse (symmetric blades, no friction); α₁: nozzle angle.
  • U/V₁ = cos α₁, η_b,max = 2cos² α₁ / (1 + cos² α₁) — optimum 50 % reaction (Parsons) stage.
  • R = Δh_rotor / Δh_stage — degree of reaction.

Vapour compression and vapour absorption refrigeration

  • COP_R = Q_L / W = (h₁ − h₄)/(h₂ − h₁) — vapour-compression cycle; 1: compressor inlet, 2: compressor outlet, 4: evaporator inlet (h₄ = h₃ by throttling).
  • RE = h₁ − h₄ — refrigerating effect (kJ/kg).
  • 1 TR = 3.517 kW — tonne of refrigeration (approximately 211 kJ/min).
  • COP_absorption = Q_evap / (Q_generator + W_pump) — vapour absorption system.
  • COP_absorption,max = (1 − T₀/T_G) · T_E/(T₀ − T_E) — ideal limit; T_G: generator, T₀: ambient, T_E: evaporator temperature (K).

Psychrometry and air conditioning load

  • ω = 0.622 p_v / (p − p_v) — humidity ratio (kg vapour/kg dry air); p_v: vapour partial pressure, p: total pressure (Pa).
  • φ = p_v / p_s — relative humidity; p_s: saturation pressure at the dry-bulb temperature.
  • μ = ω / ω_s — degree of saturation.
  • h = 1.005 t + ω (2501 + 1.88 t) — moist-air enthalpy (kJ/kg dry air), t in °C.
  • Q_s = ṁ_a c_pma (t₁ − t₂), Q_L = ṁ_a h_fg (ω₁ − ω₂) — sensible and latent loads (kW).
  • SHF = Q_s / (Q_s + Q_L), BPF = (t_out − t_coil)/(t_in − t_coil) — sensible heat factor and coil bypass factor.

One-dimensional steady conduction and fins

  • Q = −k A dT/dx — Fourier's law; Q (W), k (W/m·K), A: area normal to heat flow (m²), dT/dx (K/m).
  • R_wall = L/(kA), R_cyl = ln(r₂/r₁)/(2π k L), R_conv = 1/(hA) — thermal resistances (K/W).
  • r_c = k_ins / h (cylinder), 2k_ins/h (sphere) — critical radius of insulation (m).
  • T_max = T_s + q̇ L²/(2k) — plane wall of half-thickness L with generation q̇ (W/m³).
  • m = √(hP/(kA_c)) — fin parameter (1/m); P: perimeter (m), A_c: cross-section (m²).
  • Q_fin = √(hPkA_c) θ_b tanh(mL) — insulated-tip fin; θ_b = T_b − T∞ (K); for a long fin replace tanh(mL) by 1; for a convective tip use L_c = L + A_c/P.
  • η_f = tanh(mL)/(mL), ε_f = Q_fin/(h A_c θ_b) — fin efficiency and effectiveness.

Unsteady conduction: lumped capacitance and Heisler charts

  • Bi = h L_c / k_solid, L_c = V/A_s — Biot number; lumped model valid for Bi < 0.1 (L_c = r₀/3 sphere, r₀/2 long cylinder, half-thickness for a wall).
  • Fo = α t / L², α = k/(ρ c) — Fourier number and thermal diffusivity (m²/s).
  • (T − T∞)/(Tᵢ − T∞) = exp(−hA_s t/(ρVc)) — lumped body.
  • τ = ρ V c / (h A_s) — time constant (s).
  • (T − T_s)/(Tᵢ − T_s) = erf[x/(2√(αt))] — semi-infinite solid with a step change in surface temperature.

Forced and natural convection

  • Q = h A (T_s − T∞) — Newton's law of cooling (W).
  • Nu = hL/k_fluid, Re = VL/ν, Pr = μc_p/k, Gr = gβΔT L³/ν², Ra = Gr·Pr — dimensionless groups; β = 1/T_f (K) for an ideal gas.
  • Nu_L = 0.664 Re_L^0.5 Pr^(1/3) — laminar flat plate, average (Re_L < 5 × 10⁵).
  • Nu_L = 0.037 Re_L^0.8 Pr^(1/3) — turbulent flat plate, average.
  • Nu_D = 3.66 (uniform wall temperature), 4.36 (uniform heat flux) — fully developed laminar pipe flow (Re_D < 2300).
  • Nu_D = 0.023 Re_D^0.8 Prⁿ — Dittus–Boelter, n = 0.4 heating, 0.3 cooling (Re_D > 10 000).
  • Nu = C Raⁿ — natural convection; C and n from the data book for the geometry and range.

Radiation: black body, view factors and radiosity networks

  • E_b = σ T⁴ — black-body emissive power (W/m²); σ = 5.67 × 10⁻⁸ W/m²·K⁴, T in K.
  • λ_max T = 2898 μm·K — Wien's displacement law.
  • α + ρ + τ = 1; gray surface ε = α (Kirchhoff).
  • Σ_j F_ij = 1, A_i F_ij = A_j F_ji — summation and reciprocity rules for view factors.
  • J = ε E_b + (1 − ε) G — radiosity of an opaque gray surface (W/m²); G: irradiation.
  • q = σ(T₁⁴ − T₂⁴)/(1/ε₁ + 1/ε₂ − 1) — large parallel plates (W/m²).
  • Q = ε₁ σ A₁ (T₁⁴ − T₂⁴) — small body in a large enclosure (W).

Heat exchangers: LMTD and effectiveness-NTU methods

  • Q = U A ΔT_lm, ΔT_lm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂) — counterflow: ΔT₁ = T_h,in − T_c,out, ΔT₂ = T_h,out − T_c,in; parallel flow: ΔT₁ = T_h,in − T_c,in, ΔT₂ = T_h,out − T_c,out.
  • Q = C_h (T_h,in − T_h,out) = C_c (T_c,out − T_c,in), C = ṁ c_p — energy balance (W).
  • ε = Q / [C_min (T_h,in − T_c,in)], NTU = UA/C_min, C_r = C_min/C_max.
  • ε = [1 − exp(−NTU(1 + C_r))]/(1 + C_r) — parallel flow.
  • ε = [1 − exp(−NTU(1 − C_r))]/[1 − C_r exp(−NTU(1 − C_r))] — counterflow; ε = NTU/(1 + NTU) when C_r = 1.
  • ε = 1 − exp(−NTU) — C_r = 0 (condensing or evaporating fluid), any arrangement.

Thermal management of electronics enclosures

  • T_j = T_a + P (R_jc + R_cs + R_sa) — junction temperature (°C); P: dissipation (W), R: junction-case, case-sink, sink-ambient resistances (K/W).
  • R_sa,max = (T_j,max − T_a)/P − R_jc − R_cs — largest allowable heat-sink resistance (K/W).
  • R_TIM = t/(k A) — thermal interface layer resistance (K/W); t: thickness (m).
  • Q = h A (T_s − T_a) + ε σ A (T_s⁴ − T_a⁴) — heat lost by a sealed enclosure surface (W), radiation term in K.
  • V̇ = Q/(ρ c_p ΔT_air) — fan airflow for an allowed air temperature rise (m³/s).