Sensors, Actuators and Electric Drives — formula sheet
Mechatronics Engineering · GATE ME · SI units. Drafted with Aria, checked by the AiCanCode.org team.
Measurement System Characteristics
S = Δq_o / Δq_i— Static sensitivity; change in output per unit change in input (output unit / input unit); slope of the calibration curve.τ·dy/dt + y = K·x(t)— First-order system; τ is time constant (s), K is static sensitivity; applies to thermometers, RC filters and other single-storage elements.y(t) = K·x₀·(1 − e^(−t/τ))— First-order step response; reaches 63.2 % at t = τ and about 98 % at t = 4τ.τ = R·C— Time constant of an RC network; R in Ω, C in F, τ in s.|G(jω)| = K / √(1 + (ωτ)²),φ = −tan⁻¹(ωτ)— First-order frequency response; ω is input angular frequency (rad/s).ω_n = √(k/m),ζ = c / (2·√(k·m))— Second-order system natural frequency (rad/s) and damping ratio; k stiffness (N/m), m mass (kg), c damping (N·s/m).M_p = e^(−πζ/√(1 − ζ²))— Peak overshoot (fraction) of an underdamped (0 < ζ < 1) second-order step response.
Displacement and Position Sensors
V_o = V_s · x / L— Linear potentiometer output (unloaded); V_s supply voltage (V), x wiper displacement (m), L full travel (m).V_o = K_LVDT · x— LVDT output (amplitude of the AC differential voltage) within its linear range; K_LVDT sensitivity (V/m or mV/mm), x core displacement from null (m). Phase (0° or 180°) gives direction.θ_res = 360° / N— Resolution of an incremental encoder with N pulses (lines) per revolution; ×4 quadrature decoding gives 360° / (4N).θ_res = 360° / 2ⁿ— Resolution of an n-bit absolute encoder.
Proximity Sensors
C = ε₀·ε_r·A / d— Parallel-plate capacitance; ε₀ = 8.854 × 10⁻¹² F/m, ε_r relative permittivity, A plate area (m²), d gap (m); basis of capacitive proximity sensing.d = v·t / 2— Time-of-flight distance (ultrasonic or optical); v wave speed (m/s), t round-trip time (s).
Strain Gauges, Load Cells and Torque Sensors
ε = ΔL / L— Strain (dimensionless); ΔL change in length (m), L original length (m).GF = (ΔR/R) / ε— Gauge factor; about 2 for metal foil gauges, about 50–200 for semiconductor gauges.V_o = (V_ex/4)·GF·ε— Quarter-bridge output (small-strain approximation); V_ex bridge excitation (V).V_o = (V_ex/2)·GF·ε— Half bridge with two active arms of opposite strain.V_o = V_ex·GF·ε— Full bridge with four active arms (two +ε, two −ε).σ = E·ε— Hooke's law; E Young's modulus (Pa); elastic range only.σ = 6·F·x / (b·h²)— Surface bending stress of a rectangular cantilever load cell at distance x (m) from the load; b width (m), h thickness (m).τ_max = 16·T / (π·d³)— Shear stress on a solid circular torque shaft; T torque (N·m), d diameter (m). Gauges are bonded at ±45° to the axis, where principal strains are ±τ/(2G), G shear modulus (Pa).
Temperature Sensors
E ≈ S·(T_h − T_c)— Thermocouple EMF (linear approximation); S Seebeck coefficient (V/°C, about 41 µV/°C for type K), T_h measuring junction, T_c reference junction (°C). For accurate work use the standard reference tables.E(T_h, 0) = E(T_h, T_c) + E(T_c, 0)— Law of intermediate temperatures; basis of cold-junction compensation.R_T = R₀·(1 + α·T)— RTD (linear approximation); R₀ resistance at 0 °C (Ω), α temperature coefficient (0.00385 /°C for standard Pt100), T in °C.R_T = R₀·(1 + A·T + B·T²)— Callendar–Van Dusen equation for platinum RTDs above 0 °C; A, B from the standard.R_T = R₀·e^(β·(1/T − 1/T₀))— NTC thermistor; β material constant (K), T and T₀ in kelvin.
Pressure and Flow Sensors
p = F / A— Pressure (Pa); F force (N), A area (m²).p = ρ·g·h— Hydrostatic pressure (manometer); ρ density (kg/m³), g = 9.81 m/s², h height (m).Q = A·v— Volumetric flow rate (m³/s); A cross-sectional area (m²), v mean velocity (m/s).Q = C_d·A₂·√(2·Δp / (ρ·(1 − (A₂/A₁)²)))— Venturi or orifice meter; C_d discharge coefficient (from data book / standard), Δp differential pressure (Pa), A₁ pipe area, A₂ throat area (m²). Q ∝ √Δp.v = √(2·Δp / ρ)— Pitot-static tube velocity (incompressible flow).f = K·Q— Turbine flowmeter; f pulse frequency (Hz), K meter factor (pulses/m³) from calibration.E = B·D·v— Electromagnetic flowmeter EMF (V); B flux density (T), D pipe diameter (m), v mean velocity (m/s); conductive liquids only.
Accelerometers, Gyroscopes and IMUs
x_rel = a / ω_n²— Seismic-mass accelerometer static deflection; a acceleration (m/s²), ω_n natural frequency (rad/s); valid for input frequencies well below ω_n.q = d₃₃·F— Piezoelectric charge (C); d₃₃ charge coefficient (C/N), F force (N).F_c = 2·m·Ω × v— Coriolis force on a vibrating MEMS gyroscope proof mass; m mass (kg), Ω angular rate (rad/s), v drive velocity (m/s).θ(t) = ∫ω dt— Gyro angle by integration; a constant bias b gives drift error b·t.
Signal Conditioning
V_o = V_s·(R₂/(R₁ + R₂))— Voltage divider output; R₁, R₂ in Ω.V_o = V_s·(R₁/(R₁ + R₂) − R₄/(R₃ + R₄))— Wheatstone bridge output (one common labelling: R₁–R₂ and R₄–R₃ are the two dividers); balance when R₁·R₃ = R₂·R₄.G = −R_f / R_in— Inverting op-amp gain.G = 1 + R_f / R_g— Non-inverting op-amp gain.G = (1 + 2R/R_G)·(R₃/R₂)— Three-op-amp instrumentation amplifier gain.f_c = 1 / (2π·R·C)— Cut-off (−3 dB) frequency of a first-order RC filter (Hz).CMRR = 20·log₁₀(A_d / A_cm)— Common-mode rejection ratio (dB).
Data Acquisition Systems and Sampling
f_s > 2·f_max— Nyquist sampling criterion; f_s sampling rate (Hz), f_max highest signal frequency (Hz).f_alias = |f − k·f_s|— Apparent frequency of an under-sampled tone (choose integer k giving the value in 0 to f_s/2).Q = V_FSR / 2ⁿ— ADC resolution (LSB size, V); V_FSR full-scale range (V), n bits.SNR = 6.02·n + 1.76 dB— Ideal ADC quantisation SNR for a full-scale sine wave.e_q,max = ±Q/2— Maximum quantisation error of a rounding ADC.
DC Motors
E_b = k_e·ω(orE_b = P·Φ·Z·N / (60·A)) — Back EMF (V); k_e back-EMF constant (V·s/rad), ω speed (rad/s); Φ flux per pole (Wb), Z conductors, N speed (rpm), P poles, A parallel paths.V = E_b + I_a·R_a— Armature voltage equation (motoring); I_a armature current (A), R_a armature resistance (Ω).T = k_t·I_a— Electromagnetic torque (N·m); k_t torque constant (N·m/A). In SI units k_t = k_e.ω = V/k_e − R_a·T/(k_e·k_t)— Speed–torque line of a separately excited / PM DC motor; no-load speed V/k_e, stall torque k_t·V/R_a.P_m = E_b·I_a = T·ω— Gross mechanical power developed (W).
Induction Motors
N_s = 120·f / P— Synchronous speed (rpm); f supply frequency (Hz), P number of poles.s = (N_s − N_r) / N_s— Slip; N_r rotor speed (rpm).f_r = s·f— Rotor current frequency (Hz).T = (3/ω_s)·V²·(R₂'/s) / ((R₁ + R₂'/s)² + (X₁ + X₂')²)— Torque from the approximate equivalent circuit; ω_s synchronous speed (rad/s), V per-phase voltage (V), R₁ and X₁ stator, R₂' and X₂' rotor values referred to the stator (Ω).s_maxT = R₂' / √(R₁² + (X₁ + X₂')²)(≈R₂'/X₂'when R₁ is neglected) — Slip at maximum torque; maximum torque itself does not depend on rotor resistance.P_ag : P_cu,rotor : P_mech = 1 : s : (1 − s)— Power split across the air gap.
Variable Frequency Drives
N_s = 120·f / P— Synchronous speed set by the drive output frequency f (Hz).V / f = constant— Constant-flux (constant-torque) operation below base frequency; above base frequency V is held at rated value (field weakening, constant power).V_dc ≈ 1.35·V_LL— DC-link voltage of a three-phase diode bridge rectifier (no-load ≈ 1.414·V_LL with a large capacitor); V_LL line-to-line RMS input (V).
Stepper Motors
θ_step = 360° / (m·N_r)— Full step angle of a variable-reluctance motor; m stator phases, N_r rotor teeth. For a hybrid motorθ_step = 360° / (2·m·N_r).θ = θ_step·S— Total rotation (°) for S steps.steps/rev = 360° / θ_step.n = θ_step·f_p·60 / 360°— Speed (rpm) at step pulse rate f_p (steps/s).
AC and DC Servo Motors
T = J·α + B·ω + T_L— Torque balance; J inertia (kg·m²), α angular acceleration (rad/s²), B viscous friction (N·m·s/rad), T_L load torque (N·m).τ_m = R_a·J / (k_t·k_e)— Mechanical time constant of a DC servo (s).τ_e = L_a / R_a— Electrical time constant (s); L_a armature inductance (H).G(s) = ω(s)/V(s) = (1/k_e) / (τ_m·s + 1)— Speed transfer function of a DC servo when τ_e ≪ τ_m.
BLDC Motors and Drivers
P_out = T·ω— Output power (W); T torque (N·m), ω speed (rad/s).T = k_t·I— Torque proportional to phase current; k_t torque constant (N·m/A).E = k_e·ω— Back EMF (V); speed limited when E approaches supply voltage.n_e = (P/2)·n_m— Electrical speed or frequency from mechanical speed; P number of poles. Six-step commutation gives 6 commutation events per electrical revolution.η = P_out / P_in— Efficiency.
Solenoids, Relays and Piezo Actuators
B = μ₀·N·I / L— Flux density inside a long air-cored solenoid (T); μ₀ = 4π × 10⁻⁷ H/m, N turns, I current (A), L length (m).F = (N·I)²·μ₀·A / (2·g²)— Pull force across an air gap (N), assuming core reluctance is negligible; A pole face area (m²), g air-gap length (m). Force rises steeply as the gap closes.τ = L / R— Coil current time constant (s); sets pull-in delay.ΔL = d₃₃·V(per layer) andΔL ≈ n·d₃₃·V— Free stroke of a piezo stack with n layers; d₃₃ (m/V), V applied voltage (V).
Motor Selection for Mechatronic Systems
T_req = (J_m + J_L/n²)·α_m + T_L/(n·η)— Motor torque needed through a gearbox of ratio n (motor speed / load speed) and efficiency η.n_opt = √(J_L / J_m)— Gear ratio that maximises load acceleration for a given motor torque (inertia matching).T_rms = √(Σ T_i²·t_i / Σ t_i)— RMS torque over a duty cycle; must not exceed the motor's continuous rated torque.P = T·ω = 2π·N·T / 60— Power (W) from torque (N·m) and speed (rpm).J_eq = m·(l / 2π)²— Inertia of a linear mass m (kg) reflected through a lead screw of lead l (m/rev).