Sensors, Actuators and Electric Drives — formula sheet

Mechatronics Engineering · GATE ME · SI units. Drafted with Aria, checked by the AiCanCode.org team.

Measurement System Characteristics

  • S = Δq_o / Δq_i — Static sensitivity; change in output per unit change in input (output unit / input unit); slope of the calibration curve.
  • τ·dy/dt + y = K·x(t) — First-order system; τ is time constant (s), K is static sensitivity; applies to thermometers, RC filters and other single-storage elements.
  • y(t) = K·x₀·(1 − e^(−t/τ)) — First-order step response; reaches 63.2 % at t = τ and about 98 % at t = 4τ.
  • τ = R·C — Time constant of an RC network; R in Ω, C in F, τ in s.
  • |G(jω)| = K / √(1 + (ωτ)²), φ = −tan⁻¹(ωτ) — First-order frequency response; ω is input angular frequency (rad/s).
  • ω_n = √(k/m), ζ = c / (2·√(k·m)) — Second-order system natural frequency (rad/s) and damping ratio; k stiffness (N/m), m mass (kg), c damping (N·s/m).
  • M_p = e^(−πζ/√(1 − ζ²)) — Peak overshoot (fraction) of an underdamped (0 < ζ < 1) second-order step response.

Displacement and Position Sensors

  • V_o = V_s · x / L — Linear potentiometer output (unloaded); V_s supply voltage (V), x wiper displacement (m), L full travel (m).
  • V_o = K_LVDT · x — LVDT output (amplitude of the AC differential voltage) within its linear range; K_LVDT sensitivity (V/m or mV/mm), x core displacement from null (m). Phase (0° or 180°) gives direction.
  • θ_res = 360° / N — Resolution of an incremental encoder with N pulses (lines) per revolution; ×4 quadrature decoding gives 360° / (4N).
  • θ_res = 360° / 2ⁿ — Resolution of an n-bit absolute encoder.

Proximity Sensors

  • C = ε₀·ε_r·A / d — Parallel-plate capacitance; ε₀ = 8.854 × 10⁻¹² F/m, ε_r relative permittivity, A plate area (m²), d gap (m); basis of capacitive proximity sensing.
  • d = v·t / 2 — Time-of-flight distance (ultrasonic or optical); v wave speed (m/s), t round-trip time (s).

Strain Gauges, Load Cells and Torque Sensors

  • ε = ΔL / L — Strain (dimensionless); ΔL change in length (m), L original length (m).
  • GF = (ΔR/R) / ε — Gauge factor; about 2 for metal foil gauges, about 50–200 for semiconductor gauges.
  • V_o = (V_ex/4)·GF·ε — Quarter-bridge output (small-strain approximation); V_ex bridge excitation (V).
  • V_o = (V_ex/2)·GF·ε — Half bridge with two active arms of opposite strain.
  • V_o = V_ex·GF·ε — Full bridge with four active arms (two +ε, two −ε).
  • σ = E·ε — Hooke's law; E Young's modulus (Pa); elastic range only.
  • σ = 6·F·x / (b·h²) — Surface bending stress of a rectangular cantilever load cell at distance x (m) from the load; b width (m), h thickness (m).
  • τ_max = 16·T / (π·d³) — Shear stress on a solid circular torque shaft; T torque (N·m), d diameter (m). Gauges are bonded at ±45° to the axis, where principal strains are ±τ/(2G), G shear modulus (Pa).

Temperature Sensors

  • E ≈ S·(T_h − T_c) — Thermocouple EMF (linear approximation); S Seebeck coefficient (V/°C, about 41 µV/°C for type K), T_h measuring junction, T_c reference junction (°C). For accurate work use the standard reference tables.
  • E(T_h, 0) = E(T_h, T_c) + E(T_c, 0) — Law of intermediate temperatures; basis of cold-junction compensation.
  • R_T = R₀·(1 + α·T) — RTD (linear approximation); R₀ resistance at 0 °C (Ω), α temperature coefficient (0.00385 /°C for standard Pt100), T in °C.
  • R_T = R₀·(1 + A·T + B·T²) — Callendar–Van Dusen equation for platinum RTDs above 0 °C; A, B from the standard.
  • R_T = R₀·e^(β·(1/T − 1/T₀)) — NTC thermistor; β material constant (K), T and T₀ in kelvin.

Pressure and Flow Sensors

  • p = F / A — Pressure (Pa); F force (N), A area (m²).
  • p = ρ·g·h — Hydrostatic pressure (manometer); ρ density (kg/m³), g = 9.81 m/s², h height (m).
  • Q = A·v — Volumetric flow rate (m³/s); A cross-sectional area (m²), v mean velocity (m/s).
  • Q = C_d·A₂·√(2·Δp / (ρ·(1 − (A₂/A₁)²))) — Venturi or orifice meter; C_d discharge coefficient (from data book / standard), Δp differential pressure (Pa), A₁ pipe area, A₂ throat area (m²). Q ∝ √Δp.
  • v = √(2·Δp / ρ) — Pitot-static tube velocity (incompressible flow).
  • f = K·Q — Turbine flowmeter; f pulse frequency (Hz), K meter factor (pulses/m³) from calibration.
  • E = B·D·v — Electromagnetic flowmeter EMF (V); B flux density (T), D pipe diameter (m), v mean velocity (m/s); conductive liquids only.

Accelerometers, Gyroscopes and IMUs

  • x_rel = a / ω_n² — Seismic-mass accelerometer static deflection; a acceleration (m/s²), ω_n natural frequency (rad/s); valid for input frequencies well below ω_n.
  • q = d₃₃·F — Piezoelectric charge (C); d₃₃ charge coefficient (C/N), F force (N).
  • F_c = 2·m·Ω × v — Coriolis force on a vibrating MEMS gyroscope proof mass; m mass (kg), Ω angular rate (rad/s), v drive velocity (m/s).
  • θ(t) = ∫ω dt — Gyro angle by integration; a constant bias b gives drift error b·t.

Signal Conditioning

  • V_o = V_s·(R₂/(R₁ + R₂)) — Voltage divider output; R₁, R₂ in Ω.
  • V_o = V_s·(R₁/(R₁ + R₂) − R₄/(R₃ + R₄)) — Wheatstone bridge output (one common labelling: R₁–R₂ and R₄–R₃ are the two dividers); balance when R₁·R₃ = R₂·R₄.
  • G = −R_f / R_in — Inverting op-amp gain.
  • G = 1 + R_f / R_g — Non-inverting op-amp gain.
  • G = (1 + 2R/R_G)·(R₃/R₂) — Three-op-amp instrumentation amplifier gain.
  • f_c = 1 / (2π·R·C) — Cut-off (−3 dB) frequency of a first-order RC filter (Hz).
  • CMRR = 20·log₁₀(A_d / A_cm) — Common-mode rejection ratio (dB).

Data Acquisition Systems and Sampling

  • f_s > 2·f_max — Nyquist sampling criterion; f_s sampling rate (Hz), f_max highest signal frequency (Hz).
  • f_alias = |f − k·f_s| — Apparent frequency of an under-sampled tone (choose integer k giving the value in 0 to f_s/2).
  • Q = V_FSR / 2ⁿ — ADC resolution (LSB size, V); V_FSR full-scale range (V), n bits.
  • SNR = 6.02·n + 1.76 dB — Ideal ADC quantisation SNR for a full-scale sine wave.
  • e_q,max = ±Q/2 — Maximum quantisation error of a rounding ADC.

DC Motors

  • E_b = k_e·ω (or E_b = P·Φ·Z·N / (60·A)) — Back EMF (V); k_e back-EMF constant (V·s/rad), ω speed (rad/s); Φ flux per pole (Wb), Z conductors, N speed (rpm), P poles, A parallel paths.
  • V = E_b + I_a·R_a — Armature voltage equation (motoring); I_a armature current (A), R_a armature resistance (Ω).
  • T = k_t·I_a — Electromagnetic torque (N·m); k_t torque constant (N·m/A). In SI units k_t = k_e.
  • ω = V/k_e − R_a·T/(k_e·k_t) — Speed–torque line of a separately excited / PM DC motor; no-load speed V/k_e, stall torque k_t·V/R_a.
  • P_m = E_b·I_a = T·ω — Gross mechanical power developed (W).

Induction Motors

  • N_s = 120·f / P — Synchronous speed (rpm); f supply frequency (Hz), P number of poles.
  • s = (N_s − N_r) / N_s — Slip; N_r rotor speed (rpm).
  • f_r = s·f — Rotor current frequency (Hz).
  • T = (3/ω_s)·V²·(R₂'/s) / ((R₁ + R₂'/s)² + (X₁ + X₂')²) — Torque from the approximate equivalent circuit; ω_s synchronous speed (rad/s), V per-phase voltage (V), R₁ and X₁ stator, R₂' and X₂' rotor values referred to the stator (Ω).
  • s_maxT = R₂' / √(R₁² + (X₁ + X₂')²) (≈ R₂'/X₂' when R₁ is neglected) — Slip at maximum torque; maximum torque itself does not depend on rotor resistance.
  • P_ag : P_cu,rotor : P_mech = 1 : s : (1 − s) — Power split across the air gap.

Variable Frequency Drives

  • N_s = 120·f / P — Synchronous speed set by the drive output frequency f (Hz).
  • V / f = constant — Constant-flux (constant-torque) operation below base frequency; above base frequency V is held at rated value (field weakening, constant power).
  • V_dc ≈ 1.35·V_LL — DC-link voltage of a three-phase diode bridge rectifier (no-load ≈ 1.414·V_LL with a large capacitor); V_LL line-to-line RMS input (V).

Stepper Motors

  • θ_step = 360° / (m·N_r) — Full step angle of a variable-reluctance motor; m stator phases, N_r rotor teeth. For a hybrid motor θ_step = 360° / (2·m·N_r).
  • θ = θ_step·S — Total rotation (°) for S steps.
  • steps/rev = 360° / θ_step.
  • n = θ_step·f_p·60 / 360° — Speed (rpm) at step pulse rate f_p (steps/s).

AC and DC Servo Motors

  • T = J·α + B·ω + T_L — Torque balance; J inertia (kg·m²), α angular acceleration (rad/s²), B viscous friction (N·m·s/rad), T_L load torque (N·m).
  • τ_m = R_a·J / (k_t·k_e) — Mechanical time constant of a DC servo (s).
  • τ_e = L_a / R_a — Electrical time constant (s); L_a armature inductance (H).
  • G(s) = ω(s)/V(s) = (1/k_e) / (τ_m·s + 1) — Speed transfer function of a DC servo when τ_e ≪ τ_m.

BLDC Motors and Drivers

  • P_out = T·ω — Output power (W); T torque (N·m), ω speed (rad/s).
  • T = k_t·I — Torque proportional to phase current; k_t torque constant (N·m/A).
  • E = k_e·ω — Back EMF (V); speed limited when E approaches supply voltage.
  • n_e = (P/2)·n_m — Electrical speed or frequency from mechanical speed; P number of poles. Six-step commutation gives 6 commutation events per electrical revolution.
  • η = P_out / P_in — Efficiency.

Solenoids, Relays and Piezo Actuators

  • B = μ₀·N·I / L — Flux density inside a long air-cored solenoid (T); μ₀ = 4π × 10⁻⁷ H/m, N turns, I current (A), L length (m).
  • F = (N·I)²·μ₀·A / (2·g²) — Pull force across an air gap (N), assuming core reluctance is negligible; A pole face area (m²), g air-gap length (m). Force rises steeply as the gap closes.
  • τ = L / R — Coil current time constant (s); sets pull-in delay.
  • ΔL = d₃₃·V (per layer) and ΔL ≈ n·d₃₃·V — Free stroke of a piezo stack with n layers; d₃₃ (m/V), V applied voltage (V).

Motor Selection for Mechatronic Systems

  • T_req = (J_m + J_L/n²)·α_m + T_L/(n·η) — Motor torque needed through a gearbox of ratio n (motor speed / load speed) and efficiency η.
  • n_opt = √(J_L / J_m) — Gear ratio that maximises load acceleration for a given motor torque (inertia matching).
  • T_rms = √(Σ T_i²·t_i / Σ t_i) — RMS torque over a duty cycle; must not exceed the motor's continuous rated torque.
  • P = T·ω = 2π·N·T / 60 — Power (W) from torque (N·m) and speed (rpm).
  • J_eq = m·(l / 2π)² — Inertia of a linear mass m (kg) reflected through a lead screw of lead l (m/rev).